Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Pharm Biopharm ; 78(1): 158-65, 2011 May.
Article in English | MEDLINE | ID: mdl-21168489

ABSTRACT

The performance of the Ion-Selective Electrode (ISE) for in vitro dissolution testing using biorelevant media was evaluated in this study. In vitro dissolution was carried out using USP apparatus 2 (paddle method) with classical and with updated biorelevant media to simulate the pre- and postprandial states. The ISE was used as an analytical stand-alone system and in combination with a single-point HPLC-UV measurement. A modified method enabling the use of the ISE for very poorly soluble substances is also proposed. In terms of f(2)-factor, the results acquired using the ISE for the drug diphenhydramine-HCl were found to be very similar to the results obtained by manual sampling followed by HPLC-UV analysis. In Fed State Simulated Gastric Fluid (FeSSGF), a medium containing 50% milk, the ISE is more practical since the need to separate proteins from the analyte prior to HPLC-UV analysis is eliminated. Further work will be needed to establish ISE methodology for Fed State Simulated Intestinal Fluid (FeSSIF) media. In summary, the ISE has promise as an analytical tool for research and development applications.


Subject(s)
Potentiometry , Solubility , Body Fluids , Calibration , Chromatography, High Pressure Liquid , In Vitro Techniques , Ion-Selective Electrodes , Spectrophotometry, Ultraviolet
2.
Eur J Pharm Sci ; 34(4-5): 243-9, 2008 Aug 07.
Article in English | MEDLINE | ID: mdl-18539443

ABSTRACT

Potentiometric sensors can be used to determine the amount of API dissolved in the dissolution medium in function of time by measuring directly in the dissolution vessel of a Paddle (USP type 2) and Basket (USP type 1) apparatus. The prototype potentiometric sensor instrumentation showed very promising results for a selection of APIs with different physico-chemical properties. The applicability, benefits and limitations of the prototype were explored. The applicability of the measurement technique strongly depends on the log(P) of the API. Here, it is shown that measurements can easily be performed for APIs with a log(P)>4. Electrode performance however decreases with decreasing logP of the APIs due to decreased drug selectivity in comparison to the excipients and ionic strength of the applied dissolution medium. The potentiometric sensors are shown to be insensitive towards undissolved particles and air bubbles as opposed to UV spectrometric measurement where these can lead to severe light scattering. For the tested APIs, the obtained dissolution profiles are very reproducible and show a low variation compared to the measurements using manual sampling and UV or HPLC analysis. The measurements demonstrate that potentiometric sensors are a very promising technology that can become a standard for in situ dissolution measurements.


Subject(s)
Potentiometry/instrumentation , Technology, Pharmaceutical/instrumentation , Chromatography, High Pressure Liquid , Cinnarizine/chemistry , Domperidone/chemistry , Electrodes , Equipment Design , Excipients/chemistry , Fiber Optic Technology , Ketoconazole/chemistry , Kinetics , Loperamide/chemistry , Nephelometry and Turbidimetry , Osmolar Concentration , Reproducibility of Results , Solubility
3.
Anal Chim Acta ; 581(1): 181-91, 2007 Jan 02.
Article in English | MEDLINE | ID: mdl-17386443

ABSTRACT

The dissolution of formulations of the drugs dapoxetine, paliperidone, cinnarizine, tetrazepam, mebeverine, loperamide, galantamine and ibuprofen was studied by an in-line potentiometric measurement system. The transpose of a Nikolskii-Eisenman type function performed the conversion of potential to percentage of dissolution. A novel gradient membrane electrode was developed especially for dissolution, varying continuously in composition from an ionically conducting rubber phase to an electronically conducting solid state PVC/graphite composite. The gradient part had a thickness of 200 microm. The electrodes life span exceeded 6 months. An ion exchange procedure was used to prepare them for one specific drug. This enabled us to use one universal electrode built to measure a wide array of drugs. The system parameters such as accuracy, reproducibility and linearity were presented with the data obtained for the drug dapoxetine. In dissolution, accurate measurements were possible from 10(-9) to 10(-3) M concentrations, for high log P drugs. The effect of t(90) response times on the measurement error was estimated. The t(90) response times of the electrodes were concentration dependent, and varied between 50 and 10 s for, respectively, 10(-6) and 10(-3) M concentrations. Potential drift was studied in detail. The measurements performed with these electrodes showed an accuracy of 1%, and inter- and intra electrode variabilities of 0.6 and 1.7%, respectively. The electrodes were successfully applied in colloidal media containing suspended matter, typically formed during dissolution of tablets. The advantages and pitfalls of potentiometry over the presently used techniques for dissolution testing are discussed.


Subject(s)
Ion-Selective Electrodes , Pharmaceutical Preparations/chemistry , Technology, Pharmaceutical/instrumentation , Ion-Selective Electrodes/trends , Pharmaceutical Preparations/analysis , Solubility , Technology, Pharmaceutical/trends
SELECTION OF CITATIONS
SEARCH DETAIL
...