Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
Add more filters











Publication year range
1.
Dent Med Probl ; 60(4): 551-557, 2023.
Article in English | MEDLINE | ID: mdl-38100082

ABSTRACT

BACKGROUND: The maintenance of marginal bone integrity around dental implants continues to be a clinical challenge. It is still unclear whether loading multiple implant-supported prostheses that have different implant connections influences bone resorption. OBJECTIVES: The aim of this in vitro study was to compare stress distribution around residual edentulous ridges supported by external hexagon (EH) and Morse taper (MT) implants with screw-retained frameworks obtained with the use of different methods. MATERIAL AND METHODS: Three-element implant-supported prostheses with distal cantilevers were manufactured according to different techniques of obtaining the framework: LAS - framework sectioned and welded with a laser; TIG - framework sectioned and welded with tungsten inert gas (TIG); and CCS - framework obtained using a computer-aided design/computer-aided manufacturing (CAD/CAM) system. Occlusal and punctual loading (150 N) was applied to the cantilevers. In the photoelastic stress analysis, the fringe orders (n) were quanitified using the Tardy method, which calculates the maximum shear stress value (τ) at each selected point. RESULTS: High stress around the implants and tightening were observed in the TIG group, mainly in the crestal bone region for the EH and MT implant connections. The LAS and CCS frameworks exhibited lower stress for the MT connection under occlusal and punctual loading. CONCLUSIONS: The comparative analysis of the models showed that the MT connection type associated with the laser-welded or CAD/CAM frameworks resulted in lower stress values in the crestal bone area, suggesting the preservation of bone tissue in this region.


Subject(s)
Dental Implants , Mouth, Edentulous , Humans , Computer-Aided Design , Stress, Mechanical
2.
J Craniofac Surg ; 27(3): e276-80, 2016 May.
Article in English | MEDLINE | ID: mdl-27046468

ABSTRACT

AIMS: This study used finite element analysis to compare the biomechanical performance of splinted (SP) and nonsplinted (NSP) prostheses to regular and short length Morse taper implants in the posterior side of the mandible. METHODS: The authors used 3-dimensional geometric models of regular implants (∅4 × 11 mm) and short implants (∅4 × 5 mm) housed in the corresponding bone edges of the posterior left mandibular hemiarch involving tooth 34. The 8 experimental groups were: the control group SP (3 regular implants rehabilitated with SP), group 1SP (2 regular and 1 short implants rehabilitated with SP), group 2SP (1 regular and 2 short implants rehabilitated with SP), group 3SP (3 short implants rehabilitated with SP), the control group NSP (3 regular implants rehabilitated with NSP), group 1NSP (2 and 1 short implants rehabilitated with NSP), group 2NSP (1 regular and 2 short implants rehabilitated with NSP), and group 3NSP (3 short implants rehabilitated with NSP). Oblique forces were simulated in the molars (365 N) and premolars (200 N). Qualitative and quantitative analysis of the distribution of Von Mises equivalent stress (implants, components, and infrastructure) was performed using the AnsysWorkbench10.0 software. RESULTS AND CONCLUSIONS: The results showed that the use of SP provides several advantages and benefits, reducing the stresses placed on the implant surface, on the transmucosal abutment areas and on the interior region of the infrastructure. The use of NSP was advantageous in reducing the stresses on the abutments and in the distal interproximal area of connection between the crowns.


Subject(s)
Dental Implants , Dental Stress Analysis/methods , Finite Element Analysis , Imaging, Three-Dimensional , Models, Dental , Biomechanical Phenomena , Dental Prosthesis Design , Humans , Mandible/physiology , Mandible/surgery , Splints , Stress, Mechanical
3.
Acta Odontol Scand ; 74(2): 108-14, 2016.
Article in English | MEDLINE | ID: mdl-26028134

ABSTRACT

OBJECTIVES: To evaluate the effect of thermal cycling and inner surface treatment with aluminum oxide at different granulations on the tensile strength of Ni-Cr copings cemented with different cementing agents. MATERIALS AND METHODS: Ninety-six metal copings were manufactured and divided into two groups: before and after thermal cycling (n = 48). The copings of both groups were internally treated by sandblasting with aluminum oxide particles of 100 (n = 24) and 320 (n = 24) mesh. The copings were cemented on previously manufactured metal cores using zinc phosphate (n = 8), conventional glass ionomer (CGIC) (n = 8) and resin-modified glass ionomer (RMGIC) (n = 8) cements. The tensile strength before and after thermal cycling was then determined (Newtons). RESULTS: The tensile strength before and after thermal cycling was significantly higher in copings cemented with RMGIC compared to CGIC (p < 0.05) and was similar to that for zinc phosphate (p > 0.05). Thermal cycling and sandblasting of the inner surface of the metal copings with different granulations did not influence retention (p > 0.05). CONCLUSIONS: Zinc phosphate cements and RMGIC showed similar retention. Additionally, the retention of the cements was not influenced by either thermal cycling or the particle size of the aluminum oxide.


Subject(s)
Chromium Alloys/chemistry , Crowns , Dental Cements/chemistry , Dental Etching/methods , Aluminum Oxide/chemistry , Cementation/methods , Dental Casting Technique , Dental Prosthesis Retention , Dental Stress Analysis , Glass Ionomer Cements/chemistry , Humans , Materials Testing , Microscopy, Electron, Scanning , Particle Size , Resin Cements/chemistry , Stress, Mechanical , Surface Properties , Temperature , Tensile Strength , Zinc Phosphate Cement/chemistry
4.
Braz Dent J ; 26(6): 637-41, 2015.
Article in English | MEDLINE | ID: mdl-26963209

ABSTRACT

This research evaluated the influence of temporary cements (eugenol-containing [EC] or eugenol-free [EF]) on the tensile strength of Ni-Cr copings fixed with self-adhesive resin cement to the metal coronal substrate. Thirty-six temporary crowns were divided into 4 groups (n=9) according to the temporary cements: Provy, Dentsply (eugenol-containing), Temp Cem, Vigodent (eugenol-containing), RelyX Temp NE, 3M ESPE (eugenol-free) and Temp Bond NE, Kerr Corp (eugenol-free). After 24 h of temporary cementation, tensile strength tests were performed in a universal testing machine at a crosshead speed of 0.5 mm/min and 1 kN (100 kgf) load cell. Afterwards, the cast metal cores were cleaned by scraping with curettes and air jet. Thirty-six Ni-Cr copings were cemented to the cast metal cores with self-adhesive resin cement (RelyX U200, 3M ESPE). Tensile strength tests were performed again. In the temporary cementation, Temp Bond NE (12.91 ± 2.54) and Temp Cem (12.22 ± 2.96) presented the highest values of tensile strength and were statistically similar to each other (p>0.05). Statistically significant difference (p<0.05) was observed only between Provy (164.44 ± 31.23) and Temp Bond NE (88.48 ± 21.83) after cementation of Ni-Cr copings with self-adhesive resin cement. In addition, Temp Cem (120.68 ± 48.27) and RelyX Temp NE (103.04 ± 26.09) showed intermediate tensile strength values. In conclusion, the Provy eugenol-containing temporary cement was associated with the highest bond strength among the resin cements when Ni-Cr copings were cemented to cast metal cores. However, the eugenol cannot be considered a determining factor in increased bond strength, since the other tested cements (1 eugenol-containing and 2 eugenol-free) were similar.


Subject(s)
Dental Cements , Metals/chemistry , Chromium Alloys
5.
J Prosthodont Res ; 57(1): 24-9, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23200090

ABSTRACT

PURPOSE: The present study aimed to evaluate the retention and stress distribution of conventional (C) RPD and compare to RPD associated to implant for support (IS) and retention (IR). METHODS: Frameworks were cast from cp Ti (n=18) and Co-Cr alloy (n=18) by plasma and injected by vacuum-pressure. Conventional RPDs were compared to implant associated RPDs using a distal implant to support (IS) or to support and retain (IR) RPD. The specimens were subjected to insertion/removal cycles simulating 5 years of use and the retention force (N) was measured or evaluated. A mixed linear model was used to analyze the data (α=0.05). Photoelastic models were qualitatively examined for stress when an occlusal load of 15 kgf was applied over support teeth and RPD. RESULTS: Retention force of IR RPDs is greater than IS and C RPDs for both cp Ti and Co-Cr alloy specimens. Retention force of cp Ti RPDs increased initially and was maintained throughout 5 years of simulation test while Co-Cr RPDs presented a decrease at the beginning of the test and had their retention force maintained throughout the test. Implant placement at residual alveolar ridge decreased stress around teeth, mainly in the first premolar. Stress concentration in the IS RPD is slightly greater than in the IR RPD. CONCLUSION: The results suggest that implant placement at the distal extension improves retention and stress distribution of RPDs.


Subject(s)
Dental Implants , Denture Retention , Denture, Partial, Removable , Stress, Mechanical
6.
J Craniofac Surg ; 23(6): 1888-92, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23172434

ABSTRACT

This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.


Subject(s)
Alveolar Process/physiology , Crowns , Dental Implants , Dental Stress Analysis , Finite Element Analysis , Mandible/physiology , Alveolar Process/surgery , Biomechanical Phenomena , Humans , Mandible/surgery , Models, Dental , Software
7.
J Adv Prosthodont ; 4(3): 158-61, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22977724

ABSTRACT

PURPOSE: The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment. MATERIALS AND METHODS: Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their respective implants (3.5 × 11 mm) and after a 10 minute interval, implant/abutment assemblies were subjected to static compressive test, performed in a universal test machine with 1 mm/min displacement, at 45° inclination. The maximum deformation force was determined. Data were statistically analyzed by student t test. RESULTS: Maximum deformation force of 4.8 mm and 3.8 mm abutments was approximately 95.33 kgf and 95.25 kgf, respectively, but no fractures were noted after mechanical test. Statistical analysis demonstrated that the evaluated abutments were statistically similar (P=.230). CONCLUSION: Abutment measuring 3.8 mm in diameter (reduced) presented mechanical properties similar to 4.8 mm (conventional) abutments, enabling its clinical use as indicated.

8.
Braz Dent J ; 23(2): 141-8, 2012.
Article in English | MEDLINE | ID: mdl-22666772

ABSTRACT

The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the general alloy composition. Regarding the alloys containing nickel, the Ni-Cr and Ni-Cr-Ti alloys released 0.62 mg/L of Ni on average, while the Co-Cr dental alloy released ions between 0.01 and 0.03 mg/L of Co and Cr, respectively.The open-circuit potential stabilized at a higher level with lower deviation (standard deviation: Ni-Cr-6Ti = 32 mV/SCE and Co-Cr = 54 mV/SCE). The potenciodynamic curves of the dental alloys showed that the Ni-based dental alloy with >70 wt% of Ni had a similar curve and the Co-Cr dental alloy showed a low current density and hence a high resistance to corrosion compared with the Ni-based dental alloys. Some changes in microstructure were observed and this fact influenced the corrosion behavior for the alloys. The lower corrosion resistance also led to greater release of nickel ions to the medium. The quantity of Co ions released from the Co-Cr-Mo alloy was relatively small in the solutions. In addition, the quantity of Cr ions released into the artificial saliva from the Co-Cr alloy was lower than Cr release from the Ni-based dental alloys.


Subject(s)
Corrosion , Dental Alloys/chemistry , Saliva, Artificial/chemistry , Dielectric Spectroscopy , Electrochemistry , Ions , Potentiometry , Surface Properties
9.
J Adv Prosthodont ; 4(2): 89-92, 2012 May.
Article in English | MEDLINE | ID: mdl-22737313

ABSTRACT

PURPOSE: Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for casting implant-supported frameworks. MATERIALS AND METHODS: Three-unit implant-supported nickel-chromium (Ni-Cr) frameworks were tested for vertical misfit (n = 6). The frameworks were cast as one-piece (Group A) and later transversally sectioned through a diagonal axis (Group B) and compared to frameworks that were cast diagonally separated (Group C). All separated frameworks were laser welded. Only one side of the frameworks was screwed. RESULTS: The results on the tightened side were significantly lower in Group C (6.43 ± 3.24 µm) when compared to Groups A (16.50 ± 7.55 µm) and B (16.27 ± 1.71 µm) (P<.05). On the opposite side, the diagonal section of the one-piece castings for laser welding showed significant improvement in the levels of misfit of the frameworks (Group A, 58.66±14.30 µm; Group B, 39.48±12.03 µm; Group C, 23.13±8.24 µm) (P<.05). CONCLUSION: Casting diagonally sectioned frameworks lowers the misfit levels. Lower misfit levels for the frameworks can be achieved by diagonally sectioning one-piece frameworks.

10.
J Prosthodont Res ; 56(1): 58-64, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21324770

ABSTRACT

PURPOSE: The aim of the present study was to evaluate commercially pure titanium (CP Ti) casting quality when a specific to titanium and a conventional phosphate bonded investments were used under different mold temperatures. For this, the evaluated parameters were surface roughness, bending strength, Vickers microhardness, casting quality by radiographies and microstructure of CP Ti. METHODS: Wax patterns (28 mm × 3 mm × 1 mm) were invested using two phosphate bonded investments: Rematitan Plus (REM), specific to titanium, and Castorit Super C (CAS), a conventional investment, fired and cooled until reaching two mold temperatures: 430 °C (430) and room temperature (RT). Specimens were cast from CP Ti by plasma. After casting, specimens were radiographically examined and submitted to Vickers microhardness, roughness and bending strength evaluation. Microstructure was analyzed in the center and at the surface of specimen. RESULTS: Qualitative analysis of radiographs showed that specimens which were cast using CAS-RT presented more casting porosities while the specimens which were cast with REM-430 did not present any casting porosity. No significant difference was noted among the groups in the surface roughness and Vickers microhardness data, but the bending strength of the specimens cast using CAS was greater than REM groups. The microstructure of the specimens of the different groups was similar, presenting a feather-like aspect. CONCLUSION: Casting porosities found in the specimens cast using conventional investments (CAS) and lower mold temperatures would limit their use, even mechanical properties were similar than in specimens cast using specific to titanium investment (REM) at temperatures recommended by the manufacturer.


Subject(s)
Dental Casting Investment , Dental Casting Technique , Temperature , Titanium , Chemical Phenomena , Phosphates , Surface Properties , Titanium/chemistry
11.
J Prosthodont Res ; 56(1): 25-31, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21684233

ABSTRACT

PURPOSE: A digital image correlation (DIC) method for full-field surface strain measurement was used to analyze the effect of two veneering materials for implant supported crowns on the strain distribution within the surrounding bone. METHODS: An epoxy resin model of a bone block was made by housing acrylic resin replicas of a mandibular first premolar and second molar together with threaded implants replacing the second premolar and first molar. Porcelain-veneered (G1 and G3) and resin-veneered (G2 and G4) screw-retained splinted crowns were fabricated and loaded with (G1 and G2) and without (G3 and G4) the presence of the second molar replica. A 2-dimensional DIC measuring system was used to record surface deformation of the bone block model at a frequency of 1.0 Hz during application of a 250-N load. RESULTS: Maximum compressive strains (ɛ(XX), %) were found for the following regions: between molars, G1 (-0.21), G2 (-0.18), G3 (-0.26), and G4 (-0.25); between implants, G1 (-0.19), G2 (-0.13), G3 (-0.19), and G4 (-0.14). The magnitude of strains in the simulated bone block with the resin-veneered crowns was lower than that with porcelain-veneered crowns, irrespective of the presence or absence of the second molar. CONCLUSIONS: The softer resin veneer helped to spread the load more evenly amongst the supporting teeth and implants, thus reducing the strains in the simulant bone block. Conversely, using the harder porcelain veneer resulted in the load being concentrated within one or two teeth or implants, thus leading to higher strain values in the bone block.


Subject(s)
Bone and Bones/physiology , Crowns , Dental Implants , Dental Prosthesis, Implant-Supported , Dental Stress Analysis/methods , Stress, Mechanical , Dental Materials , Dental Veneers , Denture, Partial, Fixed , Humans , Resins, Synthetic
12.
J Biomech ; 44(9): 1735-9, 2011 Jun 03.
Article in English | MEDLINE | ID: mdl-21497352

ABSTRACT

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (τ), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey's test and correlation tests were performed using Pearson's rank correlation (α = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 ± 9.05 µm), Co-Cr (66.41 ± 35.47 µm) and Ni-Cr-Ti (32.20 ± 24.47 µm). Stresses generated by Co-Cr alloy (τ = 7.70 ± 2.16 kPa) were significantly higher than those generated by CP Ti (τ = 5.86 ± 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (τ = 5.74 ± 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials.


Subject(s)
Mandible/anatomy & histology , Metals/chemistry , Prosthesis Design/methods , Alloys/chemistry , Biomechanical Phenomena , Chromium/chemistry , Cobalt/chemistry , Dental Abutments , Dental Prosthesis, Implant-Supported , Elasticity , Humans , Materials Testing , Microscopy/methods , Nickel/chemistry , Pressure , Titanium/chemistry , Torque
13.
J Prosthodont Res ; 55(2): 69-74, 2011 Apr.
Article in English | MEDLINE | ID: mdl-20709618

ABSTRACT

The restoration of endodontically treated teeth is a topic that is extensively studied and yet remains controversial. This article emphasizes the characteristics of endodontically treated teeth and some principles to be observed when restorations of these teeth are planned. It was concluded that the amount of remaining coronal tooth structure and functional requirements determine the best way to restore these teeth, indicating the material to be used, direct or indirect restorations, associated or not to posts.


Subject(s)
Dental Restoration, Permanent/methods , Tooth, Nonvital , Humans , Post and Core Technique
14.
Braz Dent J ; 21(6): 515-9, 2010.
Article in English | MEDLINE | ID: mdl-21271041

ABSTRACT

This study compared vertical and passive fit of one-piece cast frameworks made with 3 different materials: commercially pure titanium (CP Ti - G1), cobalt-chromium alloy (Co-Cr - G2) and nickel-chromium-titanium alloy (Ni-Cr-Ti - G3). Fifteen frameworks were obtained simulating bars for fixed prosthesis in a model with 5 implants. The passive and vertical fit of the framework interface was measured using an optical microscope at x30 magnification. Data were statistically analyzed by ANOVA and LSD tests (α=0.05). Mean and standard deviation values for passive fit and vertical fit were, respectively: G1 [472.49 (109.88) µm and 29.9 (13.24) µm], G2 [584.84 (120.20) µm and 27.05 (10.30) µm], and G3 [462.70 (179.18) µm and 24.95 (11.14) µm]. For vertical fit, there were no significant differences among G1, G2 and G3 (p=0.285). There were no significant differences for passive fit between G1 and G3 (p=0.844), but both differed significantly from G2 (p=0.028 and p=0.035, respectively), which showed the highest misfit values. It may be concluded that the vertical fit of frameworks was not affected by the tested materials, and that one-piece cast frameworks resulted in inadequate passive fit. The Co-Cr alloy presented the worst values for passive fit.


Subject(s)
Chromium Alloys , Dental Prosthesis Design/adverse effects , Dental Prosthesis, Implant-Supported/adverse effects , Titanium , Analysis of Variance , Cobalt , Dental Abutments , Dental Casting Technique , Dental Implants , Endpoint Determination , Models, Dental , Nickel , Prosthesis Fitting
15.
J Appl Oral Sci ; 17(5): 421-6, 2009.
Article in English | MEDLINE | ID: mdl-19936519

ABSTRACT

UNLABELLED: Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. OBJECTIVE: The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system. MATERIAL AND METHODS: Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure. Discs were immersed in artificial saliva and subjected to different temperatures: 37 degrees C and thermocycling (37 degrees C/5 degrees C/37 degrees C/55 degrees C/37 degrees C). After thermocycling, extracts were put in a subconfluent culture during 6 h, and the number of cells and their viability were used to evaluate cytotoxicity in these temperatures. For each alloy, data from temperature conditions were compared by Student's t-test (alpha=0.05). RESULTS: The cytotoxicity tests with alloy/metal extracts showed that Ni-Cr, Co-Cr-Mo, Ti-6Al-4V and cp Ti extracts (p>0.05) did not affect cell number or cell viability, while Ni-Cr-Ti (p<0.05) extract decreased cell number and viability when the alloy was subjected to thermocycling. CONCLUSION: Within the limitations of the present study, the Ni-Cr-Ti alloy had cell number and viability decreased when subjected to temperature variation, while the other alloys/metal extracts did not show these results.


Subject(s)
Dental Alloys/toxicity , Dental Casting Investment/toxicity , Dental Materials/toxicity , Titanium/toxicity , Alloys/chemistry , Alloys/toxicity , Aluminum Oxide/chemistry , Biocompatible Materials/chemistry , Biocompatible Materials/toxicity , Carbon Compounds, Inorganic/chemistry , Cell Count , Cell Line, Tumor , Cell Survival/drug effects , Chromium Alloys/chemistry , Chromium Alloys/toxicity , Dental Alloys/chemistry , Dental Casting Investment/chemistry , Dental Casting Technique , Dental Etching , Dental Materials/chemistry , Dental Polishing/methods , Diamond/chemistry , Humans , Materials Testing , Saliva, Artificial/chemistry , Silicon Compounds/chemistry , Silicon Dioxide/chemistry , Temperature , Titanium/chemistry
16.
J Appl Oral Sci ; 17(5): 451-6, 2009.
Article in English | MEDLINE | ID: mdl-19936525

ABSTRACT

UNLABELLED: One of the most important properties of artificial teeth is the abrasion wear resistance, which is determinant in the maintenance of the rehabilitation's occlusal pattern. OBJECTIVES: This in vitro study aims to evaluate the abrasion wear resistance of 7 brands of artificial teeth opposed to two types of antagonists. MATERIAL AND METHODS: Seven groups were prepared with 12 specimens each (BIOLUX & BL, TRILUX & TR, BLUE DENT & BD, BIOCLER & BC, POSTARIS & PO, ORTHOSIT & OR, GNATHOSTAR & GN), opposed to metallic (M & nickel-chromium alloy), and to composite antagonists (C & Solidex indirect composite). A mechanical loading device was used (240 cycles/min, 4 Hz speed, 10 mm antagonist course). Initial and final contours of each specimen were registered with aid of a profile projector (20x magnification). The linear difference between the two profiles was measured and the registered values were subjected to ANOVA and Tukey's test. RESULTS: Regarding the antagonists, only OR (M = 10.45 +/- 1.42 microm and C = 2.77 +/- 0.69 microm) and BC (M = 6.70 +/- 1.37 microm and C = 4.48 +/- 0.80 microm) presented statistically significant differences (p < 0.05). Best results were obtained with PO (C = 2.33 +/- 0.91 microm and M = 1.78 +/- 0.42 microm), followed by BL (C = 3.70 +/- 1.32 microm and M = 3.70 +/- 0.61 microm), statistically similar for both antagonists (p>0.05). Greater result variance was obtained with OR, which presented the worse results opposed to Ni-Cr (10.45 +/- 1.42 microm), and results similar to the best ones against composite (2.77 +/- 0.69 microm). CONCLUSIONS: Within the limitations of this study, it may be concluded that the antagonist material is a factor of major importance to be considered in the choice of the artificial teeth to be used in the prosthesis.


Subject(s)
Composite Resins/chemistry , Dental Alloys/chemistry , Dental Materials/chemistry , Dental Restoration Wear , Tooth, Artificial , Acrylic Resins/chemistry , Chromium Alloys/chemistry , Humans , Materials Testing , Methacrylates/chemistry , Polymethyl Methacrylate/chemistry , Polyurethanes/chemistry , Stress, Mechanical , Surface Properties
17.
Clin Oral Implants Res ; 20(12): 1314-9, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19681968

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. MATERIAL AND METHODS: Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees , 7 degrees , and 14 degrees ). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). RESULTS: At 0 degrees , the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees , the retention force was statistically different at 0 and 24 months. At 14 degrees , significant differences were found from 6 and 12 to 24 months. CONCLUSIONS: Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners.


Subject(s)
Dental Prosthesis, Implant-Supported/instrumentation , Denture Retention/instrumentation , Denture, Overlay , Dental Prosthesis Design , Dental Stress Analysis , In Vitro Techniques , Linear Models , Materials Testing
18.
Int J Prosthodont ; 22(3): 283-6, 2009.
Article in English | MEDLINE | ID: mdl-19548411

ABSTRACT

The objective of this study was to verify if differences in the design of internal hex (IH) and internal conical (IC) connection implant systems influence fracture resistance under oblique compressive forces. Twenty implant-abutment assemblies were utilized: 10 with IH connections and 10 with IC connections. Maximum deformation force for IC implants (90.58 +/- 6.72 kgf) was statistically higher than that for IH implants (83.73 +/- 4.94 kgf) (P = .0182). Fracture force for the IH implants was 79.86 +/- 4.77 kgf. None of the IC implants fractured. The friction-locking mechanics and the solid design of the IC abutments provided greater resistance to deformation and fracture under oblique compressive loading when compared to the IH abutments.


Subject(s)
Dental Abutments , Dental Implants , Dental Prosthesis Design , Dental Restoration Failure , Dental Stress Analysis/instrumentation , Friction , Humans , Materials Testing , Stress, Mechanical , Surface Properties
19.
Clin Oral Implants Res ; 20(6): 624-32, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19281502

ABSTRACT

OBJECTIVES: Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. MATERIAL AND METHODS: Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P< or =0.05). RESULTS: Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased.


Subject(s)
Dental Abutments , Dental Implants , Dental Prosthesis Design , Dental Stress Analysis , Torque , Compressive Strength , Dental Restoration Failure , Stress, Mechanical , Surface Properties , Tensile Strength
20.
Braz Dent J ; 20(5): 403-9, 2009.
Article in English | MEDLINE | ID: mdl-20126909

ABSTRACT

The aim of this study was to analyze the shear bond strength between commercially pure titanium, with and without laser welding, after airbone-particle abrasion (Al(2)O(3)) and 2 indirect composites. Sixty-four specimens were cast and divided into 2 groups with and without laser welding. Each group was divided in 4 subgroups, related to Al(2)O(3) grain size: A - 250 microm; B - 180 microm; C- 110 microm; and D - 50 microm. Composite rings were formed around the rods and light polymerized using UniXS unit. Specimens were invested and their shear bond strength at failure was measured with a universal testing machine at a crosshead speed of 2.0 mm/min. Statistical analysis was carried out with ANOVA and Tukey's test (alpha=0.05). The highest bond strength means were recorded in 250 microm group without laser welding. The lowest shear bond strength means were recorded in 50 microm group with laser welding. Statistically significant differences (p<0.05) were found between all groups. In conclusion, airborne particle abrasion yielded significantly lower bond strength as the Al(2)O(3) particle size decreased. Shear bond strength decreased in the laser welded specimens.


Subject(s)
Composite Resins , Dental Alloys , Dental Soldering/methods , Light-Curing of Dental Adhesives , Titanium , Air Abrasion, Dental , Analysis of Variance , Dental Stress Analysis , Lasers , Materials Testing , Particle Size , Shear Strength , Statistics, Nonparametric , Welding/methods
SELECTION OF CITATIONS
SEARCH DETAIL