Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Neuroimage ; 58(2): 469-80, 2011 Sep 15.
Article in English | MEDLINE | ID: mdl-21718788

ABSTRACT

BACKGROUND: Medial temporal lobe (MTL) atrophy is one of the key biomarkers to detect early neurodegenerative changes in the course of Alzheimer's disease (AD). There is active research aimed at identifying automated methodologies able to extract accurate classification indexes from T1-weighted magnetic resonance images (MRI). Such indexes should be fit for identifying AD patients as early as possible. SUBJECTS: A reference group composed of 144AD patients and 189 age-matched controls was used to train and test the procedure. It was then applied on a study group composed of 302 MCI subjects, 136 having progressed to clinically probable AD (MCI-converters) and 166 having remained stable or recovered to normal condition after a 24month follow-up (MCI-non converters). All subjects came from the ADNI database. METHODS: We sampled the brain with 7 relatively small volumes, mainly centered on the MTL, and 2 control regions. These volumes were filtered to give intensity and textural MRI-based features. Each filtered region was analyzed with a Random Forest (RF) classifier to extract relevant features, which were subsequently processed with a Support Vector Machine (SVM) classifier. Once a prediction model was trained and tested on the reference group, it was used to compute a classification index (CI) on the MCI cohort and to assess its accuracy in predicting AD conversion in MCI patients. The performance of the classification based on the features extracted by the whole 9 volumes is compared with that derived from each single volume. All experiments were performed using a bootstrap sampling estimation, and classifier performance was cross-validated with a 20-fold paradigm. RESULTS: We identified a restricted set of image features correlated with the conversion to AD. It is shown that most information originate from a small subset of the total available features, and that it is enough to give a reliable assessment. We found multiple, highly localized image-based features which alone are responsible for the overall clinical diagnosis and prognosis. The classification index is able to discriminate Controls from AD with an Area Under Curve (AUC)=0.97 (sensitivity ≃89% at specificity ≃94%) and Controls from MCI-converters with an AUC=0.92 (sensitivity ≃89% at specificity ≃80%). MCI-converters are separated from MCI-non converters with AUC=0.74(sensitivity ≃72% at specificity ≃65%). FINDINGS: The present automated MRI-based technique revealed a strong relationship between highly localized baseline-MRI features and the baseline clinical assessment. In addition, the classification index was also used to predict the probability of AD conversion within a time frame of two years. The definition of a single index combining local analysis of several regions can be useful to detect AD neurodegeneration in a typical MCI population.


Subject(s)
Alzheimer Disease/diagnosis , Image Processing, Computer-Assisted/classification , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/classification , Magnetic Resonance Imaging/methods , Aged , Aged, 80 and over , Algorithms , Alzheimer Disease/pathology , Area Under Curve , Artificial Intelligence , Cognitive Dysfunction/chemically induced , Cognitive Dysfunction/pathology , Data Interpretation, Statistical , Databases, Factual , Disease Progression , Female , Follow-Up Studies , Hippocampus/physiology , Humans , Male , Reproducibility of Results
2.
J Digit Imaging ; 24(1): 11-27, 2011 Feb.
Article in English | MEDLINE | ID: mdl-19826872

ABSTRACT

A fully automated and three-dimensional (3D) segmentation method for the identification of the pulmonary parenchyma in thorax X-ray computed tomography (CT) datasets is proposed. It is meant to be used as pre-processing step in the computer-assisted detection (CAD) system for malignant lung nodule detection that is being developed by the Medical Applications in a Grid Infrastructure Connection (MAGIC-5) Project. In this new approach the segmentation of the external airways (trachea and bronchi), is obtained by 3D region growing with wavefront simulation and suitable stop conditions, thus allowing an accurate handling of the hilar region, notoriously difficult to be segmented. Particular attention was also devoted to checking and solving the problem of the apparent 'fusion' between the lungs, caused by partial-volume effects, while 3D morphology operations ensure the accurate inclusion of all the nodules (internal, pleural, and vascular) in the segmented volume. The new algorithm was initially developed and tested on a dataset of 130 CT scans from the Italung-CT trial, and was then applied to the ANODE09-competition images (55 scans) and to the LIDC database (84 scans), giving very satisfactory results. In particular, the lung contour was adequately located in 96% of the CT scans, with incorrect segmentation of the external airways in the remaining cases. Segmentation metrics were calculated that quantitatively express the consistency between automatic and manual segmentations: the mean overlap degree of the segmentation masks is 0.96 ± 0.02, and the mean and the maximum distance between the mask borders (averaged on the whole dataset) are 0.74 ± 0.05 and 4.5 ± 1.5, respectively, which confirms that the automatic segmentations quite correctly reproduce the borders traced by the radiologist. Moreover, no tissue containing internal and pleural nodules was removed in the segmentation process, so that this method proved to be fit for the use in the framework of a CAD system. Finally, in the comparison with a two-dimensional segmentation procedure, inter-slice smoothness was calculated, showing that the masks created by the 3D algorithm are significantly smoother than those calculated by the 2D-only procedure.


Subject(s)
Algorithms , Lung Neoplasms/diagnosis , Lung/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Humans , Lung Neoplasms/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed
3.
Med Phys ; 36(8): 3737-47, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19746807

ABSTRACT

The purpose of this study is to develop a software for the extraction of the hippocampus and surrounding medial temporal lobe (MTL) regions from T1-weighted magnetic resonance (MR) images with no interactive input from the user, to introduce a novel statistical indicator, computed on the intensities in the automatically extracted MTL regions, which measures atrophy, and to evaluate the accuracy of the newly developed intensity-based measure of MTL atrophy to (a) distinguish between patients with Alzheimer disease (AD), patients with amnestic mild cognitive impairment (aMCI), and elderly controls by using established criteria for patients with AD and aMCI as the reference standard and (b) infer about the clinical outcome of aMCI patients. For the development of the software, the study included 61 patients with mild AD (17 men, 44 women; mean age +/- standard deviation (SD), 75.8 years +/- 7.8; Mini Mental State Examination (MMSE) score, 24.1 +/- 3.1), 42 patients with aMCI (11 men, 31 women; mean age +/- SD, 75.2 years +/- 4.9; MMSE score, 27.9 +/- 1.9), and 30 elderly healthy controls (10 men, 20 women; mean age +/- SD, 74.7 years +/- 5.2; MMSE score, 29.1 +/- 0.8). For the evaluation of the statistical indicator, 150 patients with mild AD (62 men, 88 women; mean age +/- SD, 76.3 years +/- 5.8; MMSE score, 23.2 +/- 4.1), 247 patients with aMCI (143 men, 104 women; mean age +/- SD, 75.3 years +/- 6.7; MMSE score, 27.0 +/- 1.8), and 135 elderly healthy controls (61 men, 74 women; mean age +/- SD, 76.4 years +/- 6.1). Fifty aMCI patients were evaluated every 6 months over a 3 year period to assess conversion to AD. For each participant, two subimages of the MTL regions were automatically extracted from T1-weighted MR images with high spatial resolution. An intensity-based MTL atrophy measure was found to separate control, MCI, and AD cohorts. Group differences were assessed by using two-sample t test. Individual classification was analyzed by using receiver operating characteristic (ROC) curves. Compared to controls, significant differences in the intensity-based MTL atrophy measure were detected in both groups of patients (AD vs controls, 0.28 +/- 0.03 vs 0.34 +/- 0.03, P < 0.001; aMCI vs controls, 0.31 +/- 0.03 vs 0.34 +/- 0.03, P < 0.001). Moreover, the subgroup of aMCI converters was significantly different from controls (0.27 +/- 0.034 vs 0.34 +/- 0.03, P < 0.001). Regarding the ROC curve for intergroup discrimination, the area under the curve was 0.863 for AD patients vs controls, 0.746 for all aMCI patients vs controls, and 0.880 for aMCI converters vs controls. With specificity set at 85%, the sensitivity was 74% for AD vs controls, 45% for aMCI vs controls, and 83% for aMCI converters vs controls. The automated analysis of MTL atrophy in the segmented volume is applied to the early assessment of AD, leading to the discrimination of aMCI converters with an average 3 year follow-up. This procedure can provide additional useful information in the early diagnosis of AD.


Subject(s)
Alzheimer Disease/diagnosis , Alzheimer Disease/pathology , Atrophy , Subtraction Technique , Temporal Lobe/pathology , Aged , Automation , Female , Hippocampus/pathology , Humans , Magnetic Resonance Imaging , Male , Software , Time Factors
4.
Stud Health Technol Inform ; 112: 157-66, 2005.
Article in English | MEDLINE | ID: mdl-15923725

ABSTRACT

The main purpose of the MAGIC-5 collaboration is the development of Computer Aided Detection (CAD) software for Medical Applications on distributed databases by means of a GRID Infrastructure Connection. A prototype of the system, based on the AliEn GRID Services is already available with a central Server running common services and several clients connecting to it. It has been already successfully used for applications in mammography together with a specific CAD developed within the collaboration. Applications to the case of malignant nodule detection in lung CT scans are now being implemented, while a use of the GRID services is also being applied to PET image analysis aiming at early Alzheimer disease. One of the future prospect of our project is the migration from AliEn to the EGEE/gLite middleware which is likely to become a European standard and will certainly provide more sophisticated tools with respect to the present AliEn functionality. In this work the status of the project and its future prospects will be given, with particular attention to the data management and processing aspects. Medical applications carried on by the collaboration will be also described together with the analysis of the results so far obtained.


Subject(s)
Computer Systems , Diagnosis, Computer-Assisted/instrumentation , Neoplasms/pathology , Radiology Information Systems/instrumentation , Early Diagnosis , Europe , Female , Humans , Lung Neoplasms/diagnostic imaging , Mammography/methods , Neoplasms/prevention & control , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...