Implant Dent ; 23(2): 212-7, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24637531

ABSTRACT

PURPOSE: The purpose of this study was to compare the vertical fit of the castable abutment/implant and premachined base metal abutment/implant interface, before and after cyclic loading. MATERIALS AND METHODS: Ten UCLA abutments were distributed in 2 groups: castable and premachined with a cobalt-chromium metal base. The abutments were cast in cobalt-chromium alloy and were screwed onto implants (3.75 × 13 mm, external hexagon) with a 32 N·cm torque. The vertical gap (in micrometers) at the interface abutment/implant was evaluated by linear microscope 2 times: after torque and after cyclic load (1 million cycles, 400 N). RESULTS: The mean values of the vertical gap at the castable abutment/implant and premachined abutment/implant interfaces before and after cyclic load were 5.33 to 6.64 µm and 7.36 to 8.16 µm, respectively. The mean values of the vertical gap were statistically analyzed (ANOVA and t test, P ≤ 0.05). Vertical gap values of the castable abutment/implant interface were not significantly different from those of the premachined abutment/implant interface, before (P = 0.154) and after (P = 0.471) cyclical loading. CONCLUSION: Castable and premachined base metal abutments showed similar gaps at the implant/abutment interface, both after applying torque and after cyclic loading.


Subject(s)
Dental Implant-Abutment Design , Chromium Alloys/therapeutic use , Dental Abutments , Dental Casting Technique , Dental Implants , Dental Stress Analysis , Humans , Torque
2.
Rev. bras. odontol ; 58(2): 102-4, mar.-abr. 2001. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-296630

ABSTRACT

Este trabalho foi baseado na revisäo de literatura das causas e tratamentos das alteraçöes encontradas nos tecidos ao redor dos implantes osseointegrados, bem como a microflora envolvida. Foi observado neste relato de caso clínico periimplantite ao redor de dois implantes instalados em regiäo de pré-molares superiores. O tratamento se baseou em debridamento da ferida, aplicaçäo de tetraciclina por três minutos, enxerto autógeno e o uso de uma membrana reabsorvível. Os resultados observados demonstraram ser a regeneraçäo tecidual guiada uma técnica de grande previsibilidade no tratamento da periimplantite


Subject(s)
Humans , Female , Adult , Alveolar Bone Loss/complications , Alveolar Bone Loss/surgery , Alveolar Bone Loss/therapy , Amoxicillin/administration & dosage , Dental Implantation, Endosseous/adverse effects , Dental Implantation, Endosseous/microbiology , Guided Tissue Regeneration , Osseointegration , Tetracycline/administration & dosage