Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Heart Rhythm ; 2024 Mar 10.
Article in English | MEDLINE | ID: mdl-38467355

ABSTRACT

BACKGROUND: Cardiac conduction disorder (CCD) in patients <50 years old is a rare and mostly unknown condition. OBJECTIVE: We aimed to assess clinical characteristics and genetic background of patients <50 years old with CCD of unknown origin. METHODS: We retrospectively reviewed a consecutive series of patients with a diagnosis of CCD before the age of 50 years referred to our center between January 2019 and December 2021. Patients underwent complete clinical examination and genetic evaluation. RESULTS: We enrolled 39 patients with a median age of 40 years (28-47 years) at the onset of symptoms. A cardiac implantable electronic device was implanted in 69% of the patients. In 15 of 39 CCD index patients (38%), we found a total of 13 different gene variations (3 pathogenic, 6 likely pathogenic, and 4 variants of uncertain significance), mostly in 3 genes (SCN5A, TRPM4, and LMNA). In our cohort, genetic testing led to the decision to implant an implantable cardioverter-defibrillator in 2 patients for the increased risk of sudden cardiac death. CONCLUSION: Patients with the occurrence of CCD before the age of 50 years present with a high rate of pathologic gene variations, mostly in 3 genes (SCN5A, TRPM4, and LMNA). The presence of pathogenic variations may add information about the prognosis and lead to an individualized therapeutic approach.

2.
Biology (Basel) ; 13(2)2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38392350

ABSTRACT

BACKGROUND: At the same conditions of delivered power and contact force, open-irrigated radiofrequency ablation catheters are believed to create deeper lesions, while non-irrigated ones produce shallower lesions. This ex vivo study aims to directly compare the lesion dimensions and characteristics of an irrigated ablation catheter with a flexible tip and a non-irrigated solid-tip catheter. METHODS: Radiofrequency lesions were induced on porcine myocardial slabs using both open-tip irrigated and non-irrigated standard 4 mm catheters at three power settings (20 W, 30 W, and 40 W), maintaining a fixed contact force of 10 gr. A lesion assessment was conducted including the lesion depth, depth at the maximum diameter, and lesion surface diameters, with the subsequent calculation of the lesion volume and area being undertaken. RESULTS: Irrigated catheters produced lesions with significantly higher superficial widths at all power levels (3.8 vs. 4.4 mm at 20 W; 3.9 mm vs. 4.4 mm at 30 W; 3.8 mm vs. 4.5 mm at 40 W; p = 0.001, p = 0.019, p = 0.003, respectively). Non-irrigated catheters resulted in significantly higher superficial areas at all power levels (23 mm2 vs. 18 mm2 at 20 W; 25 mm2 vs. 19 mm2 at 30 W; 26 mm2 vs. 19 mm2 at 40 W; p = 0.001, p = 0.005, p = 0.001, respectively). Irrigated catheters showed significantly higher values of lesion maximum depth at 40 W (4.6 mm vs. 5.5 mm; p = 0.007), while non-irrigated catheters had a significantly higher calculated volume at 20 W (202 µL vs. 134 µL; p = 0.002). CONCLUSIONS: Radiofrequency ablation using an irrigated catheter with a flexible tip has the potential to generate smaller superficial lesion areas compared with those obtained using a non-irrigated catheter.

3.
JACC Clin Electrophysiol ; 10(3): 554-565, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38243998

ABSTRACT

BACKGROUND: Axillary vein puncture (AVP) and cephalic vein surgical cutdown are recommended in international guidelines because of their low risk of pneumothorax and chronic lead complications. Directly visualizing and puncturing the axillary vein under ultrasound guidance reduces radiation exposure, provides direct needle visualization, and lowers periprocedural complications. Our hypothesis is that ultrasound-guided axillary access is safer and more feasible than the standard fluoroscopic technique. OBJECTIVES: The purpose of this study was to assess the efficacy and safety of ultrasound-guided axillary venous access during cardiac lead implantation for pacemakers (PMs) and implantable cardioverter-defibrillator (ICD) implantations. METHODS: Patients were randomized in a 1:1 fashion to either axillary venous access under fluoroscopic guidance or ultrasound-guided axillary venous access. The composite outcome, including pneumothorax, hemothorax, inadvertent arterial puncture, pocket hematoma, pocket infection, lead dislodgement, and death, was evaluated 30 days after implantation. RESULTS: We randomized 270 patients into 2 groups: the standard group for fluoroguided AVP (n = 134) and the experimental group for ultrasound-guided AVP (n = 136). No disparities in baseline characteristics were observed between the groups. The median age of the patients was 81 years, with women comprising 41% of the population. The majority of patients received single- and dual-chamber PMs (87% vs 88%; P = 1.00), and slightly over 10% in both groups received ICDs (13% vs 12%; P = 0.85). In total, we placed 357 leads in PMs and 48 leads in ICDs. Among these, 295 leads were inserted via axillary vein access and 110 via cephalic vein access. Notably, the subclavian vein was never used as a vascular access. The composite outcome was lower in the ultrasound group according to intention-to-treat analysis (OR: 0.55; 95% CI: 0.31-0.99; P = 0.034). The main difference within the composite outcome was the lower incidence of inadvertent axillary arterial puncture in the experimental group (17% vs 6%; P = 0.004). The ultrasound group also exhibited lower total procedural x-ray exposure (10,344 µGy × cm2 vs 7,119 µGy × cm2; P = 0.002) while achieving the same rate of success at the first attempt (61% vs 69%; P = 0.375). CONCLUSIONS: Ultrasound-guided AVP is safer than the fluoroscopy-guided approach because it achieves the same rate of acute success while maintaining low total procedural radiation exposure. Ultrasound AVP should be considered the optimal venous access method for cardiac lead implantation. (Ultrasound Guided Axillary Access vs Standard Fluoroscopic Technique for Cardiac Lead Implantation [ZEROFLUOROAXI]; NCT05101720).


Subject(s)
Pneumothorax , Humans , Female , Aged, 80 and over , Treatment Outcome , Axillary Vein/diagnostic imaging , Axillary Vein/surgery , Ultrasonography, Interventional/methods , Fluoroscopy/methods
4.
Article in English | MEDLINE | ID: mdl-38289824

ABSTRACT

AIMS: Update data regarding the atrial fibrillation (AF)-related mortality trend in Europe remains scant. We assess the age- and sex- specific trends in AF-related mortality in the European states between the years 2008 and 2019. METHODS AND RESULTS: Data on cause-specific deaths and population numbers by sex for European countries were retrieved through the publicly available World Health Organization (WHO) mortality dataset for the years 2008 to 2019. AF-related deaths were ascertained when the ICD-10 code I48 was listed as the underlying cause of death in the medical death certificate. To calculate annual trends, we assessed the average (AAPC) annual % change with relative 95% confidence intervals (CIs) using Joinpoint regression. During the study period, 773 750 AF-related deaths (202 552 males and 571 198 females) occurred in Europe. The age-adjusted mortality rate (AAMR) linearly increased from 12.3 (95% CI: 11.2 to 12.9) per 100 000 population in 2008 to 15.3 (95% CI: 14.7 to 15.7) per 100 000 population in 2019 [AAPC: +2.0% (95% CI: 1.6 to 3.5), p < 0.001] with a more pronounced increased among men [AAPC: +2.7% (95% CI: 1.9 to 3.5), p < 0.001] compared to women [AAPC: +1.7% (95% CI: 1.1 to 2.3), p < 0.001] (p for parallelism 0.01). The higher AAMR increased was observed in some eastern European countries such as Latvia, Lithuania and Poland while the lower were mainly clustered in the central Europe. CONCLUSIONS: Over the last decade, the age-adjusted AF-related mortality has increased in Europe especially among males. Disparities still exist between western and eastern European countries.

5.
J Cardiovasc Med (Hagerstown) ; 24(12): 864-870, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37942788

ABSTRACT

AIMS: Brugada syndrome (BrS) is an inherited arrhythmic disease characterized by a coved ST-segment elevation in the right precordial electrocardiogram leads (type 1 ECG pattern) and is associated with a risk of malignant ventricular arrhythmias and sudden cardiac death. In order to assess the predictive value of the Shanghai Score System for the presence of a SCN5A mutation in clinical practice, we studied a cohort of 125 patients with spontaneous or fever/drug-induced BrS type 1 ECG pattern, variably associated with symptoms and a positive family history. METHODS: The Shanghai Score System items were collected for each patient and PR and QRS complex intervals were measured. Patients were genotyped through a next-generation sequencing (NGS) custom panel for the presence of SCN5A mutations and the common SCN5A polymorphism (H558R). RESULTS: The total Shanghai Score was higher in SCN5A+ patients than in SCN5A- patients. The 81% of SCN5A+ patients and the 100% of patients with a SCN5A truncating variant exhibit a spontaneous type 1 ECG pattern. A significant increase in PR (P = 0.006) and QRS (P = 0.02) was detected in the SCN5A+ group. The presence of the common H558R polymorphism did not significantly correlate with any of the items of the Shanghai Score, nor with the total score of the system. CONCLUSION: Data from our study suggest the usefulness of Shanghai Score collection in clinical practice in order to maximize genetic test appropriateness. Our data further highlight SCN5A mutations as a cause of conduction impairment in BrS patients.


Subject(s)
Brugada Syndrome , Humans , Brugada Syndrome/diagnosis , Brugada Syndrome/genetics , China/epidemiology , NAV1.5 Voltage-Gated Sodium Channel/genetics , Arrhythmias, Cardiac , Mutation , Electrocardiography
6.
J Cardiovasc Dev Dis ; 10(11)2023 Oct 27.
Article in English | MEDLINE | ID: mdl-37998502

ABSTRACT

BACKGROUND: Physiological pacing has gained significant interest due to its potential to achieve optimal hemodynamic response. This study aimed to assess left ventricular performance in terms of electrical parameters, specifically QRS duration and mechanical performance, evaluated as myocardial work. We compared His Bundle Pacing (HBP) and Left Bundle Branch Area Pacing (LBBAP) to evaluate their effects. METHODS: Twenty-four patients with class I or IIa indications for pacing were enrolled in this study, with twelve patients undergoing HBP implantation and another twelve undergoing LBBAP implantation. A comprehensive analysis of myocardial work was conducted. RESULTS: Our findings indicate that there were no major differences in terms of spontaneous and HBP activation in myocardial work, except for global wasted work (217 mmHg% vs. 283 mmHg%; p 0.016) and global work efficiency (87 mmHg% vs. 82 mmHg%; p 0.049). No significant differences were observed in myocardial work between spontaneous activation and LBBAP. Similarly, no significant differences in myocardial work were found between HBP and LBBAP. CONCLUSIONS: Both pacing modalities provide physiological ventricular activation without significant differences when compared to each other. Moreover, there were no significant differences in QRS duration between HBP and LBBAP. However, LBBAP demonstrated advantages in terms of feasibility, as it achieved better lead electrical parameters compared to HBP (threshold@0.4 ms 0.6 V vs. 1 V; p = 0.045-sensing 9.4 mV vs. 2.4 mV; p < 0.001). Additionally, LBBAP required less fluoroscopy time (6 min vs. 13 min; p = 0.010) and procedural time (81 min vs. 125 min; p = 0.004) compared to HBP.

8.
G Ital Cardiol (Rome) ; 24(7): 521-527, 2023 Jul.
Article in Italian | MEDLINE | ID: mdl-37392117

ABSTRACT

Epicardial adipose tissue (EAT) has various metabolic functions aiming at heart protection. When abnormal, it is related to atherosclerotic plaque development and adverse cardiovascular outcome. Additionally, in recent years, several studies have demonstrated its role in other settings such as atrial fibrillation and heart failure with preserved ejection fraction. Future studies should aim to assess diagnostic role of EAT and the effect of medical therapy on EAT volume and attenuation.


Subject(s)
Cardiovascular Diseases , Heart Failure , Humans , Cardiovascular Diseases/etiology , Risk Factors , Heart , Heart Failure/etiology , Heart Disease Risk Factors
9.
J Cardiovasc Med (Hagerstown) ; 24(9): 604-611, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37409669

ABSTRACT

AIMS: We sought to assess the atrial fibrillation/flutter (AF/AFL) mortality rates and relative trends among the Italian population between 2003 and 2017. METHODS: Data regarding the cause-specific mortality and population size by sex in 5-year age groups were extracted from the World Health Organization (WHO) global mortality database. Decedents reporting the codes I48 were extracted accordingly to the International Classification of Disease-10 (ICD-10) coding system. The age-adjusted mortality rates (AAMRs), with relative 95% confidence intervals (CIs), also stratified by sex, were determined using the direct method. Joinpoint regression analyses were used to identify periods with statistically distinct log linear trends in AF/AFL-related death rates. To calculate nationwide annual trends in AF/AFL-related mortality, we assessed the average annual percentage change (AAPC) and relative 95% CIs. RESULTS: Over the study period, 90 623 (57 109 females) AF-related deaths were recorded. The AF/AFL AAMR increased from 8.1 (95% CI: 7.8-8.2) deaths per 100 000 to 18.7 (16.9-20.0) deaths per 100 000 population. Joinpoint regression analysis revealed a linear increase in age-standardized AF/AFL-related mortality [AAPC: +3.6 (95% CI: 3.0-4.3, P  < 0.0001)] in the entire Italian population. Moreover, the mortality rate increased with age, showing a seemingly exponential distribution with a similar trend between males and females. Although the increase was more pronounced among women [AAPC: +3.7 (95% CI: 3.1-4.3, P  < 0.0001)] compared with men [AAPC: +3.4 (95% CI: 2.8-4.0, P  < 0.0001)], the difference did not reach statistical significance ( P  = 0.16). CONCLUSIONS: In Italy, the AF/AFL-related mortality rates linearly increased from 2003 to 2017.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Male , Humans , Female , Atrial Fibrillation/epidemiology , Regression Analysis , Italy/epidemiology
10.
Biology (Basel) ; 12(4)2023 Apr 17.
Article in English | MEDLINE | ID: mdl-37106806

ABSTRACT

The aim of this review is to identify possible structural abnormalities of BrS and their potential association with symptoms, risk stratification, and prognosis. (1) Background: BrS has always been considered a purely electrical disease and imaging techniques do not currently play a specific role in the diagnosis of this arrhythmic syndrome. Some authors have recently hypothesized the presence of structural and functional abnormalities. Therefore, several studies investigated the presence of pathological features in echocardiography and cardiac magnetic resonance imaging (MRI) in patients with BrS, but results were controversial. (2) Methods: We performed a systematic review of the literature on the spectrum of features detected by echocardiography and cardiac MRI. Articles were searched in Pubmed, Cochrane Library, and Biomed Central. Only papers published in English and in peer-reviewed journals up to November 2021 were selected. After an initial evaluation, 596 records were screened; the literature search identified 19 relevant articles. (3) Results: The imaging findings associated with BrS were as follows: right ventricular dilation, right ventricular wall motion abnormalities, delayed right ventricular contraction, speckle and feature tracking abnormalities, late gadolinium enhancement, and fat infiltration in the right ventricle. Furthermore, these features emerged more frequently in patients carrying the genetic mutation on the sodium voltage-gated channel α-subunit 5 (SCN5A) gene. (4) Conclusions: Specific imaging features detected by echocardiography and cardiac magnetic resonance are associated with BrS. However, this population appears to be heterogeneous and imaging anomalies emerged to be more frequent in patients carrying genetic mutations of SCN5A. Future studies with an evaluation of BrS patients are needed to identify the specific association linking the Brugada pattern, imaging abnormalities and their possible correlation with prognosis.

11.
Life (Basel) ; 12(10)2022 Oct 15.
Article in English | MEDLINE | ID: mdl-36295047

ABSTRACT

BACKGROUND: Little evidence to date has described the feasibility and diagnostic accuracy of coronary computed tomography angiography (CCTA) with noninvasive fractional flow reserve (CT-FFR) in coronary vessels with resorbable magnesium scaffold (RMS). METHODS: The SHERPA-MAGIC is a prospective study enrolling patients receiving RMS. The present analysis considered patients undergoing CCTA 18 months after the index procedure. CCTA images were employed to investigate reabsorption status, luminal measurements, and noninvasive FFR. Three-year follow-up was available for all patients. RESULTS: Overall, 26 patients with a total of 29 coronary arteries treated with 35 RMS were considered. The most frequently involved vessel was left anterior descendent (LAD). Median stent length was 25 (20-25) mm, with a median diameter of 3 (3-3.5) mm. At 18-month CCTA, all scaffolded segments were patent. Complete RMS reabsorption was observed in 27 (93%, 95% CI 77-99%) cases. Median minimal lumen diameter (MLD) and area (MLA) of the scaffolded segments were 2.5 [2.1-2.8] mm and 6.4 [4.4-8.4] mm2, respectively. Median CT-FFR was 0.88 [0.81-0.91]. Only one (3.5%) vessel showed a flow-limiting CT-FFR value ≤0.80. During the 3-year follow-up, only one (4%) adverse event was observed. Conclusions: In patients undergoing RMS implantation, CCTA including noninvasive CT-FFR evaluation is feasible and allows investigation of long-term RMS performance.

12.
Europace ; 24(3): 413-420, 2022 03 02.
Article in English | MEDLINE | ID: mdl-34487163

ABSTRACT

AIMS: In patients undergoing cardiac implantable electronic device (CIED) intervention, routine pre-procedure antibiotic prophylaxis is recommended. A more powerful antibiotic protocol has been suggested in patients at high risk of infection. Stratification of individual infective risk could guide the prophylaxis before CIED procedure. METHODS AND RESULTS: Patients undergoing CIED surgery were stratified according to the Shariff score in low and high infective risk. Patients in the 'low-risk' group were treated with only two antibiotic administrations while patients in the 'high-risk' group were treated with a prolonged 9-day protocol, according to renal function and allergies. We followed-up patients for 250 days with clinical outpatient visit and electronic control of the CIED. As primary endpoint, we evaluated CIED-related infections. A total of 937 consecutive patients were enrolled, of whom 735 were stratified in the 'low-risk' group and 202 in the 'high-risk' group. Despite different risk profiles, CIED-related infection rate at 250 days was similar in the two groups (8/735 in 'low risk' vs. 4/202 in 'high risk', P = 0.32). At multivariate analysis, active neoplasia, haematoma, and reintervention were independently associated with CIED-related infection (HR 5.54, 10.77, and 12.15, respectively). CONCLUSION: In a large cohort of patients undergoing CIED procedure, an antibiotic prophylaxis based on individual stratification of infective risk resulted in similar rate of infection between groups at high and low risk of CIED-related infection.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Prosthesis-Related Infections , Anti-Bacterial Agents/therapeutic use , Antibiotic Prophylaxis/methods , Defibrillators, Implantable/adverse effects , Electronics , Humans , Pacemaker, Artificial/adverse effects , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/prevention & control , Risk Assessment , Risk Factors
13.
J Cardiovasc Dev Dis ; 8(9)2021 Sep 09.
Article in English | MEDLINE | ID: mdl-34564127

ABSTRACT

Left ventricular noncompaction (LVNC) is a structural abnormality of the left ventricle, usually described as an isolated condition, or sometimes associated with other structural cardiac diseases. LVNC is generally asymptomatic, although it may present conduction disorders, arrhythmias, and heart failure. Here, we present the case of a patient who came to our attention with a severe LVNC phenotype associated with advanced AV conduction disorder, and supraventricular and ventricular arrhythmias at young age, in which a novel MIB1, likely pathogenic, variation has been identified.

SELECTION OF CITATIONS
SEARCH DETAIL
...