Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Interv Aging ; 14: 1379-1386, 2019.
Article in English | MEDLINE | ID: mdl-31447550

ABSTRACT

BACKGROUND: Both aortic valve stenosis and aortic stiffness are moderators of arterio ventricular coupling and independent predictors of cardiovascular morbidity and mortality. Studies on the effect of transcatheter aortic valve implantation (TAVI) on aortic functional properties are limited. We performed a study to investigate the possible short-term changes in aortic stiffness and other aortic functional properties after TAVI in older patients. METHODS: TAVI Care&Cure is an observational ongoing study including consecutive patients undergoing a TAVI procedure. Central and peripheral hemodynamic measurements were measured non invasively 1 day before (T-1) and 1 day after (T+1) TAVI using a validated oscillometric method using a brachial cuff (Mobil-O-Graph). RESULTS: 40 patients were included. Mean aortic valve area at baseline was 0.76±0.24 cm2. Indices of severity of aortic valve stenosis improved significantly. Systolic blood pressure (SBP) dropped by 8.5%, from 130.3±22.9 mmHg to 119.5±15.8 mmHg (p=0.005). Diastolic blood pressure (DBP) dropped by 13.1% from 74.8±14.5 mmHg to 65.0±11.3 mmHg (p<0.001). The arterial pulse wave velocity (aPWV) decreased from 12.05±1.99 m/s to 11.6±1.56 m/s (p=0.006). Patients with high aPWV at baseline showed a significantly larger reduction in SBP in comparison to patients with low aPWV: - 20.3 mmHg (-14.1%) vs - 3.1 mmHg (-2.6%), respectively (p=0.033). The same trend was found for the DBP: -16.2 (-20.4%) vs -4.5 mmHg (-6.3%) for high vs low aPWV at baseline (p=0.037). CONCLUSION: We found short-term changes in blood pressure and aortic stiffness after TAVI. The amplitude of the changes was the largest in patients with elevated aortic stiffness at baseline.


Subject(s)
Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve/physiology , Blood Pressure/physiology , Transcatheter Aortic Valve Replacement/methods , Vascular Stiffness/physiology , Aged , Aged, 80 and over , Aorta , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation , Hemodynamics , Humans , Male , Pulse Wave Analysis , Severity of Illness Index , Time Factors , Treatment Outcome
2.
J Geriatr Cardiol ; 15(4): 261-267, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29915615

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become the standard treatment for patients with severe symptomatic aortic stenosis (AS) considered at very high risk for surgical aortic valve replacement. The purpose of this sub-study was to evaluate long-term (> 4 years) health-related quality of life (QoL) in octogenarians who underwent TAVI. METHODS: A single center observational registry in twenty patients who underwent frame analysis assessment ≥ 4 years after TAVI. Health-related QoL was evaluated, using the Short Form-36 (SF-36), the EuroQoL-5D (EQ-5D) and the visual analogue score (EQ-VAS) questionnaires. RESULTS: The mean SF-36 subscale scores at follow-up were physical functioning 40.8 ± 26.3, role physical functioning 67.7 ± 34.9, vitality 54.6 ± 21.6, general health 52.1 ± 20.4, social functioning 63.8 ± 37.7, role emotional functioning 70.2 ± 36.0, mental health 73.2 ± 23.3 and bodily pain 80.9 ± 22.9. The mean EQ-VAS score > 4 years after TAVI was 64.7 ± 15.1. With respect to functional class, 80% of the patients were in NYHA class I/II at follow-up compared to 15% prior to TAVI. CONCLUSIONS: This sub-study reports a significant improvement in functional class (NYHA) in a selected group of very elderly patients > 4 years after TAVI. Furthermore, all patients showed a satisfactory QoL despite their age and multiple comorbidities. In addition, our study reveals a lower QoL when compared with the general age matched Dutch population.

SELECTION OF CITATIONS
SEARCH DETAIL
...