Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Radiol ; 73(2): 214.e1-214.e9, 2018 02.
Article in English | MEDLINE | ID: mdl-28911888

ABSTRACT

AIM: To prospectively investigate digital tomosynthesis (DTS) as an alternative to digital radiography (DR) for postoperative imaging of orthopaedic hardware after trauma or arthrodesis in the hand and wrist. MATERIALS AND METHODS: Thirty-six consecutive patients (12 female, median age 36 years, range 19-86 years) were included in this institutional review board approved clinical trial. Imaging was performed with DTS in dorso-palmar projection and DR was performed in dorso-palmar, lateral, and oblique views. Images were evaluated by two independent radiologists for qualitative and diagnosis-related imaging parameters using a four-point Likert scale (1=excellent, 4not diagnostic) and nominal scale. Interobserver agreement between the two readers was assessed with Cohen's kappa (k). Differences between DTS and CR were tested with Wilcoxon's signed-rank test. A p-value <0.05 was considered statistically significant. RESULTS: Regarding image quality, interobserver agreement was higher for DTS compared to DR, especially for fracture-related parameters (delineation osteosynthesis material [OSM]: KDTS0.96 versus KDR0.45; delineation fracture margins: KDTS0.78 versus KDR0.35). Delineation of fracture margins and delineation of adjacent joint spaces scored significant better for DTS compared to DR (delineation fracture margins: DTS1.54, DR2.28, p0.001; delineation adjacent joint spaces: DTS1.31, DR2.24, p0.001). Regarding diagnosis-related findings, interobserver agreement was almost equal. DTS showed a significant higher sharpness of fracture margins (DTS1.94, DR2.33, p0.04). Mean dose area product (DAP) for DTS was significant higher compared to DR (mean DR0.219 Gy·cm2, mean DTS0.903 Gy·cm2, p0.001). CONCLUSION: Fracture healing is more visible and interobserver agreement is higher for DTS compared to DR in the postoperative assessment of orthopaedic hardware in the hand and wrist.


Subject(s)
Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Hand/diagnostic imaging , Internal Fixators , Postoperative Care/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Fracture Healing , Hand/surgery , Hand Injuries/diagnostic imaging , Hand Injuries/surgery , Humans , Male , Middle Aged , Observer Variation , Prospective Studies , Wrist/diagnostic imaging , Wrist/surgery , Wrist Joint/diagnostic imaging , Wrist Joint/surgery , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...