Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 12(1): 2529, 2022 02 15.
Article in English | MEDLINE | ID: mdl-35169246

ABSTRACT

Although titanium dioxide (TiO2) is a suspected human carcinogen when inhaled, fiber-grade TiO2 (nano)particles were demonstrated in synthetic textile fibers of face masks intended for the general public. STEM-EDX analysis on sections of a variety of single use and reusable face masks visualized agglomerated near-spherical TiO2 particles in non-woven fabrics, polyester, polyamide and bi-component fibers. Median sizes of constituent particles ranged from 89 to 184 nm, implying an important fraction of nano-sized particles (< 100 nm). The total TiO2 mass determined by ICP-OES ranged from 791 to 152,345 µg per mask. The estimated TiO2 mass at the fiber surface ranged from 17 to 4394 µg, and systematically exceeded the acceptable exposure level to TiO2 by inhalation (3.6 µg), determined based on a scenario where face masks are worn intensively. No assumptions were made about the likelihood of the release of TiO2 particles itself, since direct measurement of release and inhalation uptake when face masks are worn could not be assessed. The importance of wearing face masks against COVID-19 is unquestionable. Even so, these results urge for in depth research of (nano)technology applications in textiles to avoid possible future consequences caused by a poorly regulated use and to implement regulatory standards phasing out or limiting the amount of TiO2 particles, following the safe-by-design principle.


Subject(s)
Masks , Spectrophotometry, Atomic , Titanium/analysis , COVID-19/prevention & control , COVID-19/virology , Humans , Inhalation Exposure/analysis , Metal Nanoparticles/chemistry , Microscopy, Electron, Transmission , Particle Size , SARS-CoV-2/isolation & purification , Social Control, Formal , Textiles/analysis
2.
Article in English | MEDLINE | ID: mdl-32946346

ABSTRACT

Silver (E174) is authorised as a food additive in the EU. The unknown particle size distribution of E174 is a specific concern for the E174 risk assessment. This study characterised the fraction of silver (nano)particles in 10 commercially available pristine E174 food additives and 10 E174-containing products by transmission electron microscopy (TEM) and single-particle inductively coupled plasma-mass spectrometry (spICP-MS). TEM analysis showed that all samples contained micrometre-sized flakes and also a fraction of (nano)particles. Energy-dispersive X-ray spectroscopy (EDX) and electron diffraction confirmed that the (nano)particles and micrometre-sized flakes consisted of silver. A higher amount of (nano)particles was observed in the products than in the food additives. In addition, the surface of the micrometre-sized flakes was rougher in products. The median of the minimum external dimension, assessed as minimal Feret diameter, of the fraction of (nano)particles determined by quantitative TEM analysis was 11 ± 4 nm and 18 ± 7 nm (overall mean ± standard deviation), for food additives and products, respectively. Similar size distributions were obtained by spICP-MS and TEM, considering the limit of detection of spICP-MS. The median of the equivalent spherical diameter of the fraction of (nano)particles determined by spICP-MS was 19 ± 4 nm and 21 ± 2 nm (overall mean ± standard deviation), for food additives and products, respectively. In all samples, independent of the choice of technique, the nano-sized particles represented more than 97% (by number) of the silver particles, even though the largest mass of silver was present as flakes.


Subject(s)
Food Additives/chemistry , Metal Nanoparticles/chemistry , Silver/chemistry , Acetone/chemistry , Candy , Mass Spectrometry , Microscopy, Electron, Transmission , Particle Size , Povidone/chemistry , Risk Assessment , Sodium Chloride/chemistry
3.
Nanomaterials (Basel) ; 10(3)2020 Mar 24.
Article in English | MEDLINE | ID: mdl-32213951

ABSTRACT

E171 (titanium dioxide) is a food additive that has been authorized for use as a food colorant in the European Union. The application of E171 in food has become an issue of debate, since there are indications that it may alter the intestinal barrier. This work applied standardized and validated methodologies to characterize representative samples of 15 pristine E171 materials based on transmission electron microscopy (TEM) and single-particle inductively coupled plasma mass spectrometry (spICP-MS). The evaluation of selected sample preparation protocols allowed identifying and optimizing the critical factors that determine the measurement of the particle size distribution by TEM. By combining optimized sample preparation with method validation, a significant variation in the particle size and shape distributions, the crystallographic structure (rutile versus anatase), and the physicochemical form (pearlescent pigments versus anatase and rutile E171) was demonstrated among the representative samples. These results are important for risk assessment of the E171 food additive and can contribute to the implementation of the European Food Safety Authority (EFSA) guidance on risk assessment of the application of nanoscience and nanotechnologies in the food and feed chain.

4.
Materials (Basel) ; 12(17)2019 Aug 22.
Article in English | MEDLINE | ID: mdl-31443380

ABSTRACT

E174 (silver) is a food additive that may contain silver nanoparticles (AgNP). Validated methods are needed to size and quantify these particles in a regulatory context. However, no validations have yet been performed with food additives or real samples containing food additives requiring a sample preparation step prior to analysis. A single-particle inductively coupled plasma mass spectrometry (spICP-MS) method was developed and validated for sizing and quantifying the fraction of AgNP in E174 and in products containing E174, and associated uncertainties related to sample preparation, analysis and data interpretation were unraveled. The expanded measurement uncertainty for AgNP sizing was calculated to be 16% in E174-containing food products and increased up to 23% in E174 itself. The E174 food additives showed a large silver background concentration combined with a relatively low number of nanoparticles, making data interpretation more challenging than in the products. The standard uncertainties related to sample preparation, analysis, and challenging data interpretation were respectively 4.7%, 6.5%, and 6.0% for triplicate performances. For a single replicate sample, the uncertainty related to sample preparation increased to 6.8%. The expanded measurement uncertainty related to the concentration determination was 25-45% in these complex samples, without a clear distinction between additives and products. Overall, the validation parameters obtained for spICP-MS seem to be fit for the purpose of characterizing AgNP in E174 or E174-containing products.

5.
J Vasc Res ; 45(1): 54-68, 2008.
Article in English | MEDLINE | ID: mdl-17901707

ABSTRACT

BACKGROUND/AIMS: Ligating the right lateral vitelline vein of chicken embryos (venous clip) results in cardiovascular malformations. These abnormalities are similar to malformations observed in knockout mice studies of components of the endothelin-1 (ET-1)/endothelin-converting enzyme-1/endothelin-A receptor pathway. In previous studies we demonstrated that cardiac ET-1 expression is decreased 3 h after clipping, and ventricular diastolic filling is disturbed after 2 days. Therefore, we hypothesise that ET-1-related processes are involved in the development of functional and morphological cardiovascular defects after venous clip. METHODS: In this study, ET-1 and endothelin receptor antagonists (BQ-123, BQ-788 and PD145065) were infused into the HH18 embryonic circulation. Immediate haemodynamic effects on the embryonic heart and extra-embryonic vitelline veins were examined by Doppler and micro-particle image velocimetry. Ventricular diastolic filling characteristics were studied at HH24, followed by cardiovascular morphologic investigation (HH35). RESULTS: ET-1 and its receptor antagonists induced haemodynamic effects at HH18. At HH24, a reduced diastolic ventricular passive filling component was demonstrated, which was compensated by an increased active filling component. Thinner ventricular myocardium was shown in 42% of experimental embryos. CONCLUSION: We conclude that cardiovascular malformations after venous clipping arise from a combination of haemodynamic changes and altered gene expression patterns and levels, including those of the endothelin pathway.


Subject(s)
Cardiovascular Abnormalities/metabolism , Endothelin-1/metabolism , Heart/physiopathology , Hemodynamics , Myocardium/metabolism , Receptors, Endothelin/metabolism , Signal Transduction , Yolk Sac/blood supply , Animals , Aspartic Acid Endopeptidases/genetics , Aspartic Acid Endopeptidases/metabolism , Blood Flow Velocity , Cardiac Output , Cardiovascular Abnormalities/genetics , Cardiovascular Abnormalities/pathology , Cardiovascular Abnormalities/physiopathology , Cells, Cultured , Chick Embryo , Echocardiography , Endothelin Receptor Antagonists , Endothelin-1/genetics , Endothelin-Converting Enzymes , Gene Expression Regulation, Developmental , Heart/embryology , Heart Rate , Hemodynamics/drug effects , Laser-Doppler Flowmetry , Ligation , Metalloendopeptidases/genetics , Metalloendopeptidases/metabolism , Myocardium/pathology , Oligopeptides/pharmacology , Peptides, Cyclic/pharmacology , Piperidines/pharmacology , RNA, Messenger/metabolism , Receptors, Endothelin/genetics , Signal Transduction/drug effects , Time Factors , Veins/physiopathology , Veins/surgery , Ventricular Function
6.
J Biomech ; 39(7): 1191-200, 2006.
Article in English | MEDLINE | ID: mdl-15896796

ABSTRACT

The measurement of blood-plasma velocity distributions with spatial and temporal resolution in vivo is inevitable for the determination of shear stress distributions in complex geometries at unsteady flow conditions like in the beating heart. A non-intrusive, whole-field velocity measurement technique is required that is capable of measuring instantaneous flow fields at sub-millimeter scales in highly unsteady flows. Micro particle image velocimetry (muPIV) meets these demands, but requires special consideration and methodologies in order to be utilized for in vivo studies in medical and biological research. We adapt muPIV to measure the blood-plasma velocity in the beating heart of a chicken embryo. In the current work, bio-inert, fluorescent liposomes with a nominal diameter of 400 nm are added to the flow as a tracer. Because of their small dimension and neutral buoyancy the liposomes closely follow the movement of the blood-plasma and allow the determination of the velocity gradient close to the wall. The measurements quantitatively resolve the velocity distribution in the developing ventricle and atrium of the embryo at nine different stages within the cardiac cycle. Up to 400 velocity vectors per measurement give detailed insight into the fluid dynamics of the primitive beating heart. A rapid peristaltic contraction accelerates the flow to peak velocities of 26 mm/s, with the velocity distribution showing a distinct asymmetrical profile in the highly curved section of the outflow tract. In relation to earlier published gene-expression experiments, the results underline the significance of fluid forces for embryonic cardiogenesis. In general, the measurements demonstrate that muPIV has the potential to develop into a general tool for instationary flow conditions in complex flow geometries encountered in cardiovascular research.


Subject(s)
Blood Flow Velocity/physiology , Coronary Circulation/physiology , Heart/embryology , Heart/physiology , Hemorheology/methods , Image Interpretation, Computer-Assisted/methods , Microscopy, Fluorescence/methods , Animals , Chick Embryo , Chickens , Microspheres
7.
Pediatr Res ; 57(1): 16-21, 2005 Jan.
Article in English | MEDLINE | ID: mdl-15531737

ABSTRACT

Cardiac pressure-volume relations enable quantification of intrinsic ventricular diastolic and systolic properties independent of loading conditions. The use of pressure-volume loop analysis in early stages of development could contribute to a better understanding of the relationship between hemodynamics and cardiac morphogenesis. The venous clip model is an intervention model for the chick embryo in which permanent obstruction of the right lateral vitelline vein temporarily reduces the mechanical load on the embryonic myocardium and induces a spectrum of outflow tract anomalies. We used pressure-volume loop analysis of the embryonic chick heart at stage 21 (3.5 d of incubation) to investigate whether the development of ventricular function is affected by venous clipping at stage 17, compared with normal control embryos. Steady state hemodynamic parameters demonstrated no significant differences between the venous clipped and control embryos. However, analysis of pressure-volume relations showed a significantly lower end-systolic elastance in the clipped embryos (slope of the end-systolic pressure-volume relation: 5.68 +/- 0.85 versus 11.76 +/- 2.70 mm Hg/microL, p < 0.05), indicating reduced contractility. Diastolic stiffness tended to be increased in the clipped embryos (slope of end-diastolic pressure-volume relation: 2.74 +/- 0.56 versus 1.67 +/- 0.21, p = 0.103), but the difference did not reach statistical significance. The results of the pressure-volume loop analysis show that 1 d after venous obstruction, development of ventricular function is affected, with reduced contractility. Pressure-volume analysis may be applied in the chick embryo and is a sensitive technique to detect subtle alterations in ventricular function.


Subject(s)
Blood Pressure/physiology , Embryo, Nonmammalian/physiology , Ventricular Function , Animals , Cardiac Volume , Chick Embryo , Diastole , Hemodynamics/drug effects , Models, Anatomic , Stroke Volume , Systole , Time Factors
8.
J Exp Biol ; 207(Pt 9): 1487-90, 2004 Apr.
Article in English | MEDLINE | ID: mdl-15037643

ABSTRACT

Alteration of extra-embryonic venous blood flow in stage-17 chick embryos results in well-defined cardiovascular malformations. We hypothesize that the decreased dorsal aortic blood volume flow observed after venous obstruction results in altered ventricular diastolic function in stage-24 chick embryos. A microclip was placed at the right lateral vitelline vein in a stage-17 (52-64 h of incubation) chick embryo. At stage 24 (4.5 days of incubation), we measured simultaneously dorsal aortic and atrioventricular blood flow velocities with a 20-MHz pulsed-Doppler velocity meter. The fraction of passive and active filling was integrated and multiplied by dorsal aortic blood flow to obtain the relative passive and active ventricular filling volumes. Data were summarized as means +/- S.E.M. and analyzed by t-test. At similar cycle lengths ranging from 557 ms to 635 ms (P>0.60), dorsal aortic blood flow and stroke volume measured in the dorsal aorta were similar in stage-24 clipped and normal embryos. Passive filling volume (0.07+/-0.01 mm(3)) was decreased, and active filling volume (0.40+/-0.02 mm(3)) was increased in the clipped embryo when compared with the normal embryo (0.15+/-0.01 mm(3), 0.30+/-0.01 mm(3), respectively) (P<0.003). In the clipped embryos, the passive/active ratio was decreased compared with that in normal embryos (P<0.001). Ventricular filling components changed after partially obstructing the extra-embryonic venous circulation. These results suggest that material properties of the embryonic ventricle are modified after temporarily reduced hemodynamic load.


Subject(s)
Aorta/physiology , Diastole/physiology , Heart/embryology , Ventricular Function/physiology , Animals , Blood Flow Velocity , Chick Embryo , Heart/physiology , Heart Ventricles/abnormalities , Regional Blood Flow , Stroke Volume
9.
J Exp Biol ; 206(Pt 6): 1051-7, 2003 Mar.
Article in English | MEDLINE | ID: mdl-12582147

ABSTRACT

In the venous clip model specific cardiac malformations are induced in the chick embryo by obstructing the right lateral vitelline vein with a microclip. Clipping alters venous return and intracardiac laminar blood flow patterns, with secondary effects on the mechanical load of the embryonic myocardium. We investigated the instantaneous effects of clipping the right lateral vitelline vein on hemodynamics in the stage-17 chick embryo. 32 chick embryos HH 17 were subdivided into venous clipped (N=16) and matched control embryos (N=16). Dorsal aortic blood flow velocity was measured with a 20 MHz pulsed Doppler meter. A time series of eight successive measurements per embryo was made starting just before clipping and ending 5h after clipping. Heart rate, peak systolic velocity, time-averaged velocity, peak blood flow, mean blood flow, peak acceleration and stroke volume were determined. All hemodynamic parameters decreased acutely after venous clipping and only three out of seven parameters (heart rate, time-averaged velocity and mean blood flow) showed a recovery to baseline values during the 5h study period. We conclude that the experimental alteration of venous return has major acute effects on hemodynamics in the chick embryo. These effects may be responsible for the observed cardiac malformations after clipping.


Subject(s)
Chick Embryo/physiology , Hemodynamics/physiology , Animals , Blood Flow Velocity/physiology , Heart/embryology , Heart/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...