ABSTRACT
We constructed internal controls (ICs) to provide assurance that clinical specimens are successfully amplified and detected. The IC nucleic acids contain primer binding regions identical to those of the target sequence and contain a unique probe binding region that differentiates the IC from amplified target nucleic acid. Because only 20 copies of the IC are introduced into each test sample, a positive IC signal indicates that amplification was sufficient to generate a positive signal from targets present at the limit of test sensitivity. The COBAS AMPLICOR Chlamydia trachomatis, Neisseria gonorrhoeae, Mycobacterium tuberculosis, and human hepatitis C virus tests exhibited inhibition rates ranging from 5 to 9%. Approximately 64% of these inhibitory specimens were not inhibitory when a second aliquot was tested. Because repeatedly inhibitory specimens were not reported as false negative and because additional infected specimens were detected during retesting, test sensitivities were 1 to 6% greater than they would have been if the IC had not been used.
Subject(s)
Polymerase Chain Reaction , False Negative Reactions , Humans , Sensitivity and SpecificityABSTRACT
A coamplification PCR test for the direct detection of Neisseria gonorrhoeae and Chlamydia trachomatis in urethral and endocervical swabs and urine samples from men and women was compared to standard culture techniques. Processed specimens were amplified in single reaction tubes containing primers for both organisms, and PCR products were detected by a colorimetric microwell plate hybridization assay specific for each pathogen. Of 344 specimens from men, 45 (13.1%) urine specimens were PCR positive for C. trachomatis, 51 (14.8%) urethral swab specimens were PCR positive, and 29 urethral swab specimens (8.4%) were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for C. trachomatis were 96.2 and 99.3%, respectively, in urethral swab specimens, compared to 88.2 and 98.6% for urine specimens. Of the 192 specimens from women, 28 (14.6%) urine specimens were PCR positive for C. trachomatis, 32 (16.7%) endocervical specimens were PCR positive, and 19 (9.9%) endocervical specimens were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for C. trachomatis for endocervical specimens were both 100% compared to 100 and 99.4%, respectively, for urine specimens from women. In men, 68 (19.8%) urine specimens were PCR positive for N. gonorrhoeae, 73 (21.2%) urethral swabs were PCR positive, and 59 (17.2%) urethral swabs were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for N. gonorrhoeae were 97.3 and 97.0%, respectively, for urethral specimens compared to 94.4 and 98.5% for urine specimens. In women, 18 (9.4%) urine specimens were PCR positive for N. gonorrhoeae, 23 (12.0%) were endocervical swab PCR positive, and 15 (7.8%) endocervical specimens were culture positive. After analysis of discrepancies, the resolved sensitivity and specificity of PCR for N. gonorrhoeae were 100 and 99.4%, respectively, for endocervical specimens compared to 90.0 and 95.9% for female urine specimens. These results indicate that a multiplex PCR is highly sensitive for detecting both C. trachomatis and N. gonorrhoeae from a single urine or genital swab, providing a more cost-effective way of screening multiple pathogens.