Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 217
Filter
1.
Lab Chip ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38952211

ABSTRACT

Paper-based rapid diagnostic tests (RDTs) are an essential component of modern healthcare, particularly for the management of infectious diseases. Despite their utility, these capillary-driven RDTs are compromised by high failure rates, primarily caused by user error. This limits their utility in complex assays that require multiple user operations. Here, we demonstrate how this issue can be directly addressed through continuous electrochemical monitoring of reagent flow inside an RDT using embedded graphenized electrodes. Our method relies on applying short voltage pulses and measuring variations in capacitive discharge currents to precisely determine the flow times of injected samples and reagents. This information is reported to the user, guiding them through the testing process, highlighting failure cases and ultimately decreasing errors. Significantly, the same electrodes can be used to quantify electrochemical signals from immunoassays, providing an integrated solution for both monitoring assays and reporting results. We demonstrate the applicability of this approach in a serology test for the detection of anti-SARS-CoV-2 IgG in clinical serum samples. This method paves the way towards "smart" RDTs able to continuously monitor the testing process and improve the robustness of point-of-care diagnostics.

2.
ACS Sens ; 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38978209

ABSTRACT

Clustered Regularly Interspaced Short Palindromic Repeats-CRISPR-Associated Protein (CRISPR-Cas) systems have evolved several mechanisms to specifically target foreign DNA. These properties have made them attractive as biosensors. The primary drawback associated with contemporary CRISPR-Cas biosensors is their weak signaling capacity, which is typically compensated for by coupling the CRISPR-Cas systems to nucleic acid amplification. An alternative strategy to improve signaling capacity is to engineer the reporter, i.e., design new signal-generating substrates for Cas proteins. Unfortunately, due to their reliance on custom synthesis, most of these engineered reporter substrates are inaccessible to many researchers. Herein, we investigate a substrate based on a fluorescein (FAM)-tetramethylrhodamine (TAMRA) Förster resonant energy-transfer (FRET) pair that functions as a seamless "drop-in" replacement for existing reporters, without the need to change any other aspect of a CRISPR-Cas12a-based assay. The reporter is readily available and employs FRET to produce two signals upon cleavage by Cas12a. The use of both signals in a ratiometric manner provides for improved assay performance and a decreased time-to-result for several CRISPR-Cas12a assays when compared to a traditional FAM-Black Hole Quencher (BHQ) quench-based reporter. We comprehensively characterize this reporter to better understand the reasons for the improved signaling capacity and benchmark it against the current standard CRISPR-Cas reporter. Finally, to showcase the real-world utility of the reporter, we employ it in a Recombinase Polymerase Amplification (RPA)-CRISPR-Cas12a DNA Endonuclease-Targeted CRISPR Trans Reporter (DETECTR) assay to detect Human papillomavirus in patient-derived samples.

3.
Anal Chem ; 96(25): 10443-10450, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38864271

ABSTRACT

Due to their ability to selectively target pathogen-specific nucleic acids, CRISPR-Cas systems are increasingly being employed as diagnostic tools. "One-pot" assays that combine nucleic acid amplification and CRISPR-Cas systems (NAAT-CRISPR-Cas) in a single step have emerged as one of the most popular CRISPR-Cas biosensing formats. However, operational simplicity comes at a cost, with one-pot assays typically being less sensitive than corresponding two-step NAAT-CRISPR-Cas assays and often failing to detect targets at low concentrations. It is thought that these performance reductions result from the competition between the two enzymatic processes driving the assay, namely, Cas-mediated cis-cleavage and polymerase-mediated amplification of the target DNA. Herein, we describe a novel one-pot RPA-Cas12a assay that circumvents this issue by leveraging in situ complexation of the target-specific sgRNA and Cas12a to purposefully limit the concentration of active Cas12a during the early stages of the assay. Using a clinically relevant assay against a DNA target for HPV-16, we show how this in situ format reduces competition between target cleavage and amplification and engenders significant improvements in detection limit when compared to the traditional one-pot assay format, even in patient-derived samples. Finally, to gain further insight into the assay, we use experimental data to formulate a mechanistic model describing the competition between the Cas enzyme and nucleic acid amplification. These findings suggest that purposefully limiting cis-cleavage rates of Cas proteins is a viable strategy for improving the performance of one-pot NAAT-CRISPR-Cas assays.


Subject(s)
CRISPR-Associated Proteins , CRISPR-Cas Systems , RNA, Guide, CRISPR-Cas Systems , CRISPR-Cas Systems/genetics , CRISPR-Associated Proteins/metabolism , RNA, Guide, CRISPR-Cas Systems/metabolism , Humans , Endodeoxyribonucleases/metabolism , Endodeoxyribonucleases/chemistry , Bacterial Proteins/metabolism , Bacterial Proteins/genetics , Bacterial Proteins/chemistry , Nucleic Acid Amplification Techniques , Replication Protein A/metabolism , Biosensing Techniques/methods
4.
Chem Sci ; 15(23): 8982-8992, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38873052

ABSTRACT

Affinity protein-oligonucleotide conjugates are increasingly being explored as diagnostic and therapeutic tools. Despite growing interest, these probes are typically constructed using outdated, non-selective chemistries, and little has been done to investigate how conjugation to oligonucleotides influences the function of affinity proteins. Herein, we report a novel site-selective conjugation method for furnishing affinity protein-oligonucleotide conjugates in a 93% yield within fifteen minutes. Using SPR, we explore how the choice of affinity protein, conjugation strategy, and DNA length impact target binding and reveal the deleterious effects of non-specific conjugation methods. Furthermore, we show that these adverse effects can be minimised by employing our site-selective conjugation strategy, leading to improved performance in an immuno-PCR assay. Finally, we investigate the interactions between affinity protein-oligonucleotide conjugates and live cells, demonstrating the benefits of site-selective conjugation. This work provides critical insight into the importance of conjugation strategy when constructing affinity protein-oligonucleotide conjugates.

5.
Adv Healthc Mater ; : e2400800, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38808536

ABSTRACT

A major challenge for the regeneration of chronic wounds is an underlying dysregulation of signaling molecules, including inflammatory cytokines and growth factors. To address this, it is proposed to use granular biomaterials composed of jammed microgels, to enable the rapid uptake and delivery of biomolecules, and provide a strategy to locally sequester and release biomolecules. Sequestration assays on model biomolecules of different sizes demonstrate that granular hydrogels exhibit faster transport than comparable bulk hydrogels due to enhanced surface area and decreased diffusion lengths. To demonstrate the potential of modular granular hydrogels to modulate local biomolecule concentrations, microgel scaffolds are engineered that can simultaneously sequester excess pro-inflammatory factors and release pro-healing factors. To target specific biomolecules, microgels are functionalized with affinity ligands that bind either to interleukin 6 (IL-6) or to vascular endothelial growth factor A (VEGF-A). Finally, disparate microgels are combined into a single granular biomaterial for simultaneous sequestration of IL-6 and release of VEGF-A. Overall, the potential of modular granular hydrogels is demonstrated to locally tailor the relative concentrations of pro- and anti-inflammatory factors.

6.
Small ; : e2401148, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38801400

ABSTRACT

Electrochemical paper-based microfluidics has attracted much attention due to the promise of transforming point-of-care diagnostics by facilitating quantitative analysis with low-cost and portable analyzers. Such devices harness capillary flow to transport samples and reagents, enabling bioassays to be executed passively. Despite exciting demonstrations of capillary-driven electrochemical tests, conventional methods for fabricating electrodes on paper impede capillary flow, limit fluidic pathways, and constrain accessible device architectures. This account reviews recent developments in paper-based electroanalytical devices and offers perspective by revisiting key milestones in lateral flow tests and paper-based microfluidics engineering. The study highlights the benefits associated with electrochemical sensing and discusses how the detection modality can be leveraged to unlock novel functionalities. Particular focus is given to electrofluidic platforms that embed electrodes into paper for enhanced biosensing applications. Together, these innovations pave the way for diagnostic technologies that offer portability, quantitative analysis, and seamless integration with digital healthcare, all without compromising the simplicity of commercially available rapid diagnostic tests.

7.
Small ; : e2301074, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38659180

ABSTRACT

The coating of filter media with silver is typically achieved by chemical deposition and aerosol processes. Whilst useful, such approaches struggle to provide uniform coating and are prone to blockage. To address these issues, an in situ method for coating glass fibers is presented via the dopamine-mediated electroless metallization method, yielding filters with low air resistance and excellent antibacterial performance. It is found that the filtration efficiency of the filters is between 94 and 97% and much higher than that of silver-coated filters produced using conventional dipping methods (85%). Additionally, measured pressure drops ranged between 100 and 150 Pa, which are lower than those associated with dipped filters (171.1 Pa). Survival rates of Escherichia coli and Bacillus subtilis bacteria exposed to the filters decreased to 0 and 15.7%±1.49, respectively after 2 h, with no bacteria surviving after 6 h. In contrast, survival rates of E. coli and B. subtilis bacteria on the uncoated filters are 92.5% and 89.5% after 6 h. Taken together, these results confirm that the in situ deposition of silver onto fiber surfaces effectively reduces pore clogging, yielding low air resistance filters that can be applied for microbial filtration and inhibition in a range of environments.

8.
Curr Opin Biotechnol ; 87: 103097, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38430713

ABSTRACT

Enzymes are widely used as catalysts in the chemical and pharmaceutical industries. While successful in many situations, they must usually be adapted to operate efficiently under nonnatural conditions. Enzyme engineering allows the creation of novel enzymes that are stable at elevated temperatures or have higher activities and selectivities. Current enzyme engineering techniques require the production and testing of enzyme variant libraries to identify members with desired attributes. Unfortunately, traditional screening methods cannot screen such large mutagenesis libraries in a robust and timely manner. Droplet-based microfluidic systems can produce, process, and sort picoliter droplets at kilohertz rates and have emerged as powerful tools for library screening and thus enzyme engineering. We describe how droplet-based microfluidics has been used to advance directed evolution.


Subject(s)
Directed Molecular Evolution , Microfluidics , Directed Molecular Evolution/methods , Microfluidics/methods , Enzymes/metabolism , Enzymes/genetics , Enzymes/chemistry , Protein Engineering/methods
9.
Langmuir ; 40(12): 6304-6316, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38494636

ABSTRACT

Freezing and freeze-drying processes are commonly used to extend the shelf life of drug products and to ensure their safety and efficacy upon use. When designing a freezing process, it is beneficial to characterize multiple physicochemical properties of the formulation, such as nucleation rate, crystal growth rate, temperature and concentration of the maximally freeze-concentrated solution, and melting point. Differential scanning calorimetry has predominantly been used in this context but does have practical limitations and is unable to quantify the kinetics of crystal growth and nucleation. In this work, we introduce a microfluidic technique capable of quantifying the properties of interest and use it to investigate aqueous sucrose solutions of varying concentration. Three freeze-thaw cycles were performed on droplets with 75-µm diameters at cooling and warming rates of 1 °C/min. During each cycle, the visual appearance of the droplets was optically monitored as they experienced nucleation, crystal growth, formation of the maximally freeze-concentrated solution, and melting. Nucleation and crystal growth manifested as increases in droplet brightness during the cooling phase. Heating was associated with a further increase as the temperature associated with the maximally freeze-concentrated solution was approached. Heating beyond the melting point corresponded to a decrease in brightness. Comparison with the literature confirmed the accuracy of the new technique while offering new visual data on the maximally freeze-concentrated solution. Thus, the microfluidic technique presented here may serve as a complement to differential scanning calorimetry in the context of freezing and freeze-drying. In the future, it could be applied to a plethora of mixtures that undergo such processing, whether in pharmaceutics, food production, or beyond.

10.
Angew Chem Int Ed Engl ; 63(17): e202401080, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38421342

ABSTRACT

The role of monoclonal antibodies as vehicles to deliver payloads has evolved as a powerful tool in cancer therapy in recent years. The clinical development of therapeutic antibody conjugates with precise payloads holds great promise for targeted therapeutic interventions. The use of affinity-peptide mediated functionalization of native off-the-shelf antibodies offers an effective approach to selectively modify IgG antibodies with a drug-antibody ratio (DAR) of 2. Here, we report the traceless, peptide-directed attachment of two hydroxylamines to native IgGs followed by chemoselective potassium acyltrifluoroborate (KAT) ligation with quinolinium acyltrifluoroborates (QATs), which provide enhanced ligation rates with hydroxylamines under physiological conditions. By applying KAT ligation to the modified antibodies, conjugation of small molecules, proteins, and oligonucleotides to off-the-shelf IgGs proceeds efficiently, in good yields, and with simultaneous cleavage of the affinity peptide-directing moiety.


Subject(s)
Immunoglobulin G , Lysine , Hydroxylamines , Peptides/chemistry , Antibodies, Monoclonal/chemistry
11.
ACS Sens ; 9(1): 474-482, 2024 01 26.
Article in English | MEDLINE | ID: mdl-38171016

ABSTRACT

We present an ultrahigh-throughput, real-time fluorescence cytometer comprising a viscoelastic microfluidic system and a complementary metal-oxide-semiconductor (CMOS) linear image sensor-based detection system. The flow cytometer allows for real-time quantification of a variety of fluorescence species, including micrometer-sized particles and cells, at analytical throughputs in excess of 400,000 species per second. The platform integrates a custom C++ control program and graphical user interface (GUI) to allow for the processing of raw signals, adjustment of processing parameters, and display of fluorescence intensity histograms in real time. To demonstrate the efficacy of the platform for rare event detection and its utility as a basic clinical tool, we measure and quantify patient-derived circulating tumor cells (CTCs) in peripheral blood, realizing that detection has a sensitivity of 6 CTCs per million blood cells (0.000006%) with a volumetric throughput of over 3 mL/min.


Subject(s)
Microfluidics , Neoplastic Cells, Circulating , Humans , Flow Cytometry/methods
13.
Chimia (Aarau) ; 77(5): 312-318, 2023 May 31.
Article in English | MEDLINE | ID: mdl-38047827

ABSTRACT

Microfluidic methods for the synthesis of nanomaterials allow the generation of high-quality products with outstanding structural, electronic and optical properties. At a fundamental level, this is engendered by the ability to control both heat and mass transfer in a rapid and precise manner, but also by the facile integration of in-line characterization tools and machine learning algorithms. Such integrated platforms provide for exquisite control over material properties during synthesis, accelerate the optimization of electronic and optical properties and bestow new insights into the optoelectronic properties of nanomaterials. Herein, we present a brief perspective on the role that microfluidic technologies can play in nanomaterial synthesis, with a particular focus on recent studies that incorporate in-line optical characterization and machine learning. We also consider the importance and challenges associated with integrating additional functional components within experimental workflows and the upscaling of microfluidic platforms for production of industrial-scale quantities of nanomaterials.

14.
ACS Sens ; 8(11): 3986-3987, 2023 11 24.
Article in English | MEDLINE | ID: mdl-37997657

Subject(s)
DNA , Base Sequence
15.
Chem Soc Rev ; 52(24): 8531-8579, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37882143

ABSTRACT

Human-infecting pathogens that transmit through the air pose a significant threat to public health. As a prominent instance, the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that caused the COVID-19 pandemic has affected the world in an unprecedented manner over the past few years. Despite the dissipating pandemic gloom, the lessons we have learned in dealing with pathogen-laden aerosols should be thoroughly reviewed because the airborne transmission risk may have been grossly underestimated. From a bioanalytical chemistry perspective, on-site airborne pathogen detection can be an effective non-pharmaceutic intervention (NPI) strategy, with on-site airborne pathogen detection and early-stage infection risk evaluation reducing the spread of disease and enabling life-saving decisions to be made. In light of this, we summarize the recent advances in highly efficient pathogen-laden aerosol sampling approaches, bioanalytical sensing technologies, and the prospects for airborne pathogen exposure measurement and evidence-based transmission interventions. We also discuss open challenges facing general bioaerosols detection, such as handling complex aerosol samples, improving sensitivity for airborne pathogen quantification, and establishing a risk assessment system with high spatiotemporal resolution for mitigating airborne transmission risks. This review provides a multidisciplinary outlook for future opportunities to improve the on-site airborne pathogen detection techniques, thereby enhancing the preparedness for more on-site bioaerosols measurement scenarios, such as monitoring high-risk pathogens on airplanes, weaponized pathogen aerosols, influenza variants at the workplace, and pollutant correlated with sick building syndromes.


Subject(s)
COVID-19 , Pandemics , Humans , Pandemics/prevention & control , Respiratory Aerosols and Droplets , COVID-19/diagnosis , COVID-19/prevention & control , SARS-CoV-2
16.
Sci Adv ; 9(40): eadi5296, 2023 10 06.
Article in English | MEDLINE | ID: mdl-37801500

ABSTRACT

Small extracellular vesicles (sEVs; <200 nm) that contain lipids, nucleic acids, and proteins are considered promising biomarkers for a wide variety of diseases. Conventional methods for sEV isolation from blood are incompatible with routine clinical workflows, significantly hampering the utilization of blood-derived sEVs in clinical settings. Here, we present a simple, viscoelastic-based microfluidic platform for label-free isolation of sEVs from human blood. The separation performance of the device is assessed by isolating fluorescent sEVs from whole blood, demonstrating purities and recovery rates of over 97 and 87%, respectively. Significantly, our viscoelastic-based microfluidic method also provides for a remarkable increase in sEV yield compared to gold-standard ultracentrifugation, with proteomic profiles of blood-derived sEVs purified by both methods showing similar protein compositions. To demonstrate the clinical utility of the approach, we isolate sEVs from blood samples of 20 patients with cancer and 20 healthy donors, demonstrating that elevated sEV concentrations can be observed in blood derived from patients with cancer.


Subject(s)
Extracellular Vesicles , Neoplasms , Humans , Microfluidics , Proteomics , Coloring Agents
17.
J Photochem Photobiol B ; 247: 112783, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37688839

ABSTRACT

In 2018, Ashwin and co-workers presented a method for the selective and sensitive detection of Pd2+ based on variations in the fluorescence of coumarin (C460). Herein, we re-evaluate the ability of C460 to probe Pd2+ concentration via a systematic reproduction of the experiments reported in the original publication and the performance of additional control experiments. Our analysis indicates that C460 is in fact not a fluorescence sensor for Pd2+, but rather can act as a pH sensor over a restricted pH range. Furthermore, we are of the opinion that the experimental procedures described in the original paper were inaccurately or incompletely presented, particularly with regard to sample preparation. To support our conclusions, we provide a detailed assessment of the fluorescence properties of C460 in aqueous media as a function of pH. To summarize, our analysis suggests that reductions in fluorescence are not due to molecular interactions with palladium species, but instead result from the inhibition of intramolecular charge transfer (ICT) caused by the protonation of the amine group at low pH values.

18.
Anal Chem ; 95(39): 14526-14532, 2023 10 03.
Article in English | MEDLINE | ID: mdl-37733469

ABSTRACT

We present a portable imaging flow cytometer comprising a smartphone, a small-footprint optical framework, and a PDMS-based microfluidic device. Flow cytometric analysis is performed in a sheathless manner via elasto-inertial focusing with a custom-written Android program, integrating a graphical user interface (GUI) that provides a high degree of user control over image acquisition. The proposed system offers two different operational modes. First, "post-processing" mode enables particle/cell sizing at throughputs of up to 67 000 particles/s. Alternatively, "real-time" mode allows for integrated cell/particle classification with machine learning at throughputs of 100 particles/s. To showcase the efficacy of our platform, polystyrene particles are accurately enumerated within heterogeneous populations using the post-processing mode. In real-time mode, an open-source machine learning algorithm is deployed within a custom-developed Android application to classify samples containing cells of similar size but with different morphologies. The flow cytometer can extract high-resolution bright-field images with a spatial resolution <700 nm using the developed machine learning-based algorithm, achieving classification accuracies of 97% and 93% for Jurkat and EL4 cells, respectively. Our results confirm that the smartphone imaging flow cytometer (sIFC) is capable of both enumerating single particles in flow and identifying morphological features with high resolution and minimal hardware.


Subject(s)
Diagnostic Imaging , Smartphone , Flow Cytometry/methods , Algorithms , Single-Cell Analysis
19.
ACS Sens ; 8(10): 3964-3972, 2023 10 27.
Article in English | MEDLINE | ID: mdl-37756250

ABSTRACT

The development of low-cost, disposable electrochemical sensors is an essential step in moving traditionally inaccessible quantitative diagnostic assays toward the point of need. However, a major remaining limitation of current technologies is the reliance on standardized reference electrode materials. Integrating these reference electrodes considerably restricts the choice of the electrode substrate and drastically increases the fabrication costs. Herein, we demonstrate that adoption of two-electrode detection systems can circumvent these limitations and allow for the development of low-cost, paper-based devices. We showcase the power of this approach by developing a continuous flow assay for urinary creatinine enabled by an embedded graphenic two-electrode detector. The detection system not only simplifies sensor fabrication and readout hardware but also provides a robust sensing performance with high detection efficiencies. In addition to enabling high-throughput analysis of clinical urine samples, our two-electrode sensors provide unprecedented insights into the fundamental mechanism of the ferricyanide-mediated creatinine reaction. Finally, we developed a simplified circuitry to drive the detector. This forms the basis of a smart reader that guides the user through the measurement process. This study showcases the potential of affordable capillary-driven cartridges for clinical analysis within primary care settings.


Subject(s)
Electrochemical Techniques , Urinalysis , Creatinine , Electrodes
20.
Nat Methods ; 20(10): 1479-1482, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37749213

ABSTRACT

Probing non-equilibrium dynamics with single-molecule spectroscopy is important for dissecting biomolecular mechanisms. However, existing microfluidic rapid-mixing systems for this purpose are incompatible with surface-adhesive biomolecules, exhibit undesirable flow dispersion and are often demanding to fabricate. Here we introduce droplet-based microfluidic mixing for single-molecule spectroscopy to overcome these limitations in a wide range of applications. We demonstrate its robust functionality with binding kinetics of even very surface-adhesive proteins on the millisecond timescale.

SELECTION OF CITATIONS
SEARCH DETAIL
...