Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Interv Neuroradiol ; : 15910199221142097, 2022 Dec 15.
Article in English | MEDLINE | ID: mdl-36523190

ABSTRACT

MATERIALS AND METHODS: We performed a retrospective review of our prospectively maintained database to identify all patients treated with the Embotrap 3 stent-retriever between January 2021 and January 2022. We recorded the baseline demographics, NIHSS, ASPECT score and clot characteristics, first pass and final eTICI scores, complications and 90 day mRS. RESULTS: One hundred and ten patients met the inclusion criteria, average age 69 ± 14 years, 50% were male (n = 55). The median NIHSS at presentation was 18 (range 3-30) and 58.2% received IV tPA prior to MT. The median ASPECT score on plain CT was 8 with average clot length 20.2 ± 14.8 mm (n = 93). The first pass effect (FPE) was seen in 41.8% of cases with modified FPE seen in 59.1%. A 24-hour CT scan (n = 97) showed median ASPECTs of 7. 43.8% of patients achieve mRS ≤ 2 at 90-day mRS (n = 64). CONCLUSION: The Embotrap 3 stent-retriever has a high rate of FPE and final recanalization in this real world cohort of patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...