Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Radiol ; 89(1058): 20150603, 2016.
Article in English | MEDLINE | ID: mdl-26585543

ABSTRACT

OBJECTIVE: To determine if subsets of patients may benefit from smaller or larger margins when using laser setup and bony anatomy verification of breast tumour bed (TB) boost radiotherapy (RT). METHODS: Verification imaging data acquired using cone-beam CT, megavoltage CT or two-dimensional kilovoltage imaging on 218 patients were used (1574 images). TB setup errors for laser-only setup (dlaser) and for bony anatomy verification (dbone) were determined using clips implanted into the TB as a gold standard for the TB position. Cases were grouped by centre-, patient- and treatment-related factors, including breast volume, TB position, seroma visibility and surgical technique. Systematic (Σ) and random (σ) TB setup errors were compared between groups, and TB planning target volume margins (MTB) were calculated. RESULTS: For the study population, Σlaser was between 2.8 and 3.4 mm, and Σbone was between 2.2 and 2.6 mm, respectively. Females with larger breasts (p = 0.03), easily visible seroma (p ≤ 0.02) and open surgical technique (p ≤ 0.04) had larger Σlaser. Σbone was larger for females with larger breasts (p = 0.02) and lateral tumours (p = 0.04). Females with medial tumours (p < 0.01) had smaller Σbone. CONCLUSION: If clips are not used, margins should be 8 and 10 mm for bony anatomy verification and laser setup, respectively. Individualization of TB margins may be considered based on breast volume, TB and seroma visibility. ADVANCES IN KNOWLEDGE: Setup accuracy using lasers and bony anatomy is influenced by patient and treatment factors. Some patients may benefit from clip-based image guidance more than others.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Cone-Beam Computed Tomography/methods , Radiotherapy Setup Errors/prevention & control , Adult , Aged , Aged, 80 and over , Anatomic Landmarks , Breast Neoplasms/pathology , Female , Humans , Middle Aged , Neoplasm Recurrence, Local , Patient Positioning , Photons , Radiographic Image Interpretation, Computer-Assisted , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided , United Kingdom
2.
Radiother Oncol ; 109(3): 482-6, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24128804

ABSTRACT

BACKGROUND AND PURPOSE: To measure the geometric uncertainty resulting from intra-fraction motion and intra-observer image matching, for patients having image-guided prostate radiotherapy on TomoTherapy. MATERIAL AND METHODS: All patients had already been selected for prostate radiotherapy on TomoTherapy, with daily MV-CT imaging. The study involved performing an additional MV-CT image at the end of treatment, on 5 occasions during the course of 37 treatments. 54 patients were recruited to the study. A new formula was derived to calculate the PTV margin for intra-fraction motion. RESULTS: The mean values of the intra-fraction differences were 0.0mm, 0.5mm, 0.5mm and 0.0° for LR, SI, AP and roll, respectively. The corresponding standard deviations were 1.1mm, 0.8mm, 0.8mm and 0.6° for systematic uncertainties (Σ), 1.3mm, 2.0mm, 2.2mm and 0.3° for random uncertainties (σ). This intra-fraction motion requires margins of 2.2mm in LR, 2.1mm in SI and 2.1mm in AP directions. Inclusion of estimates of the effect of rotations and matching errors increases these margins to approximately 4mm in LR and 5mm in SI and AP directions. CONCLUSIONS: A new margin recipe has been developed to calculate margins for intra-fraction motion. This recipe is applicable to any measurement technique that is based on the difference between images taken before and after treatment.


Subject(s)
Prostatic Neoplasms/pathology , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Humans , Male , Motion , Radiotherapy Dosage , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...