Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Parasit Vectors ; 11(1): 606, 2018 Nov 27.
Article in English | MEDLINE | ID: mdl-30482239

ABSTRACT

BACKGROUND: Decisions on when vector control can be withdrawn after malaria is eliminated depend on the receptivity or potential of an area to support vector populations. To guide malaria control and elimination programmes, the potential of biting rates, sporozoite rates, entomological inoculation rates and parity rates to estimate malaria receptivity and transmission were compared within and among geographically localised villages of active transmission in the Western Province of the Solomon Islands. RESULTS: Malaria transmission and transmission potential was heterogeneous in both time and space both among and within villages as defined by anopheline species composition and biting densities. Biting rates during the peak biting period (from 18:00 to 00:00 h) of the primary vector, Anopheles farauti, ranged from less than 0.3 bites per person per half night in low receptivity villages to 26 bites per person in highly receptive villages. Within villages, sites with high anopheline biting rates were significantly clustered. Sporozoite rates provided evidence for continued transmission of Plasmodium falciparum, P. vivax and P. ovale by An. farauti and for incriminating An. hinesorum, as a minor vector, but were unreliable as indicators of transmission intensity. CONCLUSIONS: In the low transmission area studied, sporozoite, entomological inoculation and parity rates could not be measured with the precision required to provide guidance to malaria programmes. Receptivity and potential transmission risk may be most reliably estimated by the vector biting rate. These results support the meaningful design of operational research programmes to ensure that resources are focused on providing information that can be utilised by malaria control programmes to best understand both transmission, transmission risk and receptivity across different areas.


Subject(s)
Anopheles/physiology , Disease Eradication/methods , Insect Bites and Stings , Malaria/transmission , Mosquito Control/methods , Mosquito Vectors/physiology , Animals , Anopheles/parasitology , Female , Humans , Longitudinal Studies , Malaria/epidemiology , Malaria/prevention & control , Malaria, Vivax/parasitology , Malaria, Vivax/prevention & control , Malaria, Vivax/transmission , Melanesia/epidemiology , Mosquito Vectors/parasitology , Plasmodium falciparum/isolation & purification , Plasmodium falciparum/physiology , Plasmodium vivax/isolation & purification , Plasmodium vivax/physiology , Seasons , Sporozoites/isolation & purification
2.
Malar J ; 16(1): 230, 2017 05 31.
Article in English | MEDLINE | ID: mdl-28569159

ABSTRACT

BACKGROUND: Molecular tools for detecting malaria-infected mosquitoes with improved practicality, sensitivity and specificity, and high-throughput are required. A common PCR technique used to detect mosquitoes infected with Plasmodium spp. is a nested PCR assay based on the 18s-rRNA gene. However, this technique has several technical limitations, is laborious and time consuming. METHODS: In this study, a PCR-based on the Plasmodium cytochrome oxidase I (COX-I) gene was compared with the 18s-rRNA nested PCR using serial dilutions (330-0.0012 pg) of DNA from Plasmodium vivax, Plasmodium falciparum and Plasmodium knowlesi and with DNA from 48 positive and negative Kenyan mosquitoes (previously detected by using both ELISA and PCR). This assay for Plasmodium spp. DNA detection using the fast COX-I PCR assay was then performed individually on 2122 field collected mosquitoes (from the Solomon Islands) in which DNA was extracted from head and thorax. RESULTS: The fast COX-I PCR assay took 1 h to run and consistently detected as low as to 0.043 pg of parasite DNA (equivalent to two parasites) in a single PCR, while analyses with the 18s-rRNA nested PCR required 4 h to complete with a consistent detection threshold of 1.5 pg of DNA. Both assays produced concordant results when applied to the 48 Kenyan control samples with known Plasmodium spp. infection status. The fast COX-I PCR identified 23/2122 Plasmodium-infected mosquitoes from the Solomon Islands. CONCLUSIONS: This new COX-I PCR adapted for a single PCR reaction is a faster, simpler, cheaper, more sensitive technique amenable to high-throughput analyses for Plasmodium DNA detection in mosquitoes and is comparable to the 18s-rRNA nested PCR. The improved sensitivity seen with the fast COX-I PCR will improve the accuracy of mosquito infection rate determination.


Subject(s)
High-Throughput Nucleotide Sequencing/methods , Plasmodium falciparum/isolation & purification , Plasmodium knowlesi/isolation & purification , Plasmodium vivax/isolation & purification , Polymerase Chain Reaction/methods , Protozoan Proteins/analysis , Animals , Anopheles/parasitology , Electron Transport Complex IV/analysis , Female , Melanesia , Plasmodium falciparum/enzymology , Plasmodium knowlesi/enzymology , Plasmodium vivax/enzymology , RNA, Ribosomal, 18S/analysis , Sensitivity and Specificity , Sporozoites/enzymology , Sporozoites/isolation & purification
3.
Malar J ; 15: 128, 2016 Feb 29.
Article in English | MEDLINE | ID: mdl-26928594

ABSTRACT

BACKGROUND: Nested PCRs based on the Plasmodium 18s-rRNA gene have been extensively used for human malaria diagnosis. However, they are not practical when large quantities of samples need to be processed, further there have been challenges in the performance and when interpreting results, especially when submicroscopic infections are analysed. Here the use of "direct PCR" was investigated with the aim of improving diagnosis in the malaria elimination era. METHODS: The performance of the Plasmodium cytochrome oxidase III gene (COX-III) based novel malaria detection strategies (direct nested PCR and direct single PCR) were compared using a 18s-rRNA direct nested PCR as a reference tool. Evaluations were based on sensitivity, specificity and the ability to detect mixed infections using control blood spot samples and field collected blood samples with final species diagnosis confirmation by sequencing. RESULTS: The COX-III direct PCR (limit of detection: 0.6-2 parasites/µL) was more sensitive than the 18s-rRNA direct nested PCR (limit of detection: 2-10 parasites/µL). The COX-III direct PCR identified all 21 positive controls (no mixed infections detected) while the 18s-rRNA direct nested PCR identified 18/21 (including four mixed infections). Different concentrations of simulated mixed infections (Plasmodium vivax and Plasmodium falciparum) suggest that the COX-III direct PCR detects only the predominant species. When the 18s-rRNA direct nested PCR was used to detect Plasmodium in field collected bloods spots (n = 3833), there was discrepancy in the results from the genus PCR (16 % positive) and the species-specific PCR (5 % positive). Further, a large portion of a subset of these positive samples (93 % for genus and 60 % for P. vivax), did not align with Plasmodium sequences. In contrast, the COX-III direct PCR clearly identified (single bands confirmed with sequencing) 2 % positive Plasmodium samples including P. vivax, P. falciparum, Plasmodium malariae and Plasmodium ovale wallikeri. CONCLUSIONS: The COX-III single direct PCR is an alternative method for accurate detection of Plasmodium microscopic and submicroscopic infections in humans, especially when a large number of samples require screening. This PCR does not require DNA isolation, is sensitive, quick, produces confident/clear results, identifies all the Plasmodium species infecting humans, and is cost-effective.


Subject(s)
Electron Transport Complex IV/genetics , Malaria/diagnosis , Plasmodium/genetics , Protozoan Proteins/genetics , Base Sequence , DNA, Protozoan/blood , DNA, Protozoan/genetics , Dried Blood Spot Testing , Humans , Limit of Detection , Malaria/parasitology , Molecular Sequence Data , Parasitemia/diagnosis , Polymerase Chain Reaction , Sequence Alignment
4.
Sci Rep ; 5: 17952, 2015 Dec 09.
Article in English | MEDLINE | ID: mdl-26648001

ABSTRACT

The understanding of malaria vector species in association with their bionomic traits is vital for targeting malaria interventions and measuring effectiveness. Many entomological studies rely on morphological identification of mosquitoes, limiting recognition to visually distinct species/species groups. Anopheles species assignments based on ribosomal DNA ITS2 and mitochondrial DNA COI were compared to morphological identifications from Luangwa and Nyimba districts in Zambia. The comparison of morphological and molecular identifications determined that interpretations of species compositions, insecticide resistance assays, host preference studies, trap efficacy, and Plasmodium infections were incorrect when using morphological identification alone. Morphological identifications recognized eight Anopheles species while 18 distinct sequence groups or species were identified from molecular analyses. Of these 18, seven could not be identified through comparison to published sequences. Twelve of 18 molecularly identified species (including unidentifiable species and species not thought to be vectors) were found by PCR to carry Plasmodium sporozoites - compared to four of eight morphological species. Up to 15% of morphologically identified Anopheles funestus mosquitoes in insecticide resistance tests were found to be other species molecularly. The comprehension of primary and secondary malaria vectors and bionomic characteristics that impact malaria transmission and intervention effectiveness are fundamental in achieving malaria elimination.


Subject(s)
Anopheles/classification , Biodiversity , Animals , Anopheles/drug effects , Anopheles/genetics , Behavior, Animal , DNA, Intergenic , Genes, Insect , Insect Vectors , Insecticide Resistance , Mosquito Control/methods , Phylogeny , Sequence Analysis, DNA , Zambia
SELECTION OF CITATIONS
SEARCH DETAIL
...