Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Agric Food Chem ; 72(14): 7980-7990, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38562102

ABSTRACT

Prebiotic oligosaccharides have attracted immense interest in the infant formula (IF) industry due to their unique health benefits for infants. There is a need for the reasonable supplementation of prebiotics in premium IF products. Herein, we characterized the profile of galacto-oligosaccharides (GOS) in human milk (HM) and IF using ultrahigh-performance liquid chromatography-cyclic ion mobility-mass spectrometry (UPLC-cIM-MS) technique. Additionally, we further performed a targeted quantitative analysis of five essential HM oligosaccharides (HMOs) in HM (n = 196), IF (n = 50), and raw milk of IF (n = 10) by the high-sensitivity UPLC-MS/MS method. HM exhibited a more abundant and variable HMO composition (1183.19 to 2892.91 mg/L) than IF (32.91 to 56.31 mg/L), whereas IF contained extra GOS species and non-negligible endogenous 3'-sialyllactose. This also facilitated the discovery of secretor features within the Chinese population. Our study illustrated the real disparity in the prebiotic glycome between HM and IF and provided crucial reference for formula improvement.


Subject(s)
Infant Formula , Milk, Human , Infant , Humans , Milk, Human/chemistry , Infant Formula/chemistry , Prebiotics/analysis , Liquid Chromatography-Mass Spectrometry , Chromatography, Liquid , Chromatography, High Pressure Liquid , Tandem Mass Spectrometry , Oligosaccharides/chemistry
2.
J Chromatogr A ; 1710: 464435, 2023 Nov 08.
Article in English | MEDLINE | ID: mdl-37820461

ABSTRACT

Phospholipids (PLs) are important and complex trace lipids in milk, which have positive effects on the infants' nervous and immune system development. Herein, a new method for selective extraction of PLs using glass fabric @ MOF-808 was proposed. Based on Lewis acid-base interaction, MOF-808 containing abundant Zr-OH groups was selected as the adsorption body, and glass fabric was used as a substrate to make the adsorbent easy to remove and reuse. The influencing factors such as loading solution, extraction time, eluent and elution time were further investigated. The adsorbent showed high adsorption capacity (3.31-6.54 mg/g for PLs) and good reusability (reused at least five times). The method showed low detection limits (1.61 µg/L - 10.24 µg/L) and quantification limits (5.24 µg/L-51.21 µg/L) for eight classes of PLs. The analysis of PLs in human milk at different lactation stages by ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry could obtain up to 206 PLs, indicating that the method has extremely high extraction and anti-interference capabilities. This work is the first time to introduce MOF materials to selectively extract PLs and use glass fabric as a substrate for MOF-808, which has the advantages of easy recovery and high sensitivity. It provides technical support for the discovery of more PL species and has potential applications in phospholipidomics.


Subject(s)
Metal-Organic Frameworks , Milk, Human , Humans , Milk, Human/chemistry , Phospholipids/chemistry , Metal-Organic Frameworks/chemistry , Zirconium/chemistry , Chromatography, High Pressure Liquid/methods , Solid Phase Extraction/methods
3.
J Chromatogr A ; 1658: 462606, 2021 Nov 22.
Article in English | MEDLINE | ID: mdl-34656840

ABSTRACT

Milk lipids are one of the most complex materials in nature and are associated with many physiological functions, hence it is important to comprehensively characterize lipids profiles to evaluate the nutritional value of milk. A quick method was developed by ultra-high performance supercritical fluid chromatography coupled to electrospray ionization quadrupole time-of-flight mass spectrometry (UHPSFC-ESI-QTOF-MS) to analyze the non-polar and polar lipids profiles of cow, goat, buffalo, human milk, and infant formulas in 7 min. All chromatographic conditions were carefully optimized and their effect on the chromatographic behavior of lipid classes and species was discussed. Under optimized conditions, 12 lipid classes (triacylglycerols, diacylglycerols, monoglyceride, fatty acids, phosphatidylcholine, phosphatidylethanolamine, phosphatidylinositol, phosphatidylserine, phosphatidylglycerol, sphingomyelin, lyso-phosphatidylcholine, and lyso-phosphatidylethanolamine) were separated and each class was further separated in single analysis to facilitate the identification. 250 lipid species in real samples were characterized and quantified. This result demonstrates the applicability of the UHPSFC-ESI-QTOF-MS method in the high-throughput and comprehensive lipid analysis of milk, and will hopefully help to provide nutritionists with the lipid distribution in different types of milk, as well as help in the design of more suitable infant formula for babies.


Subject(s)
Chromatography, Supercritical Fluid , Animals , Cattle , Chromatography, High Pressure Liquid , Female , Milk, Human , Phosphatidylcholines , Spectrometry, Mass, Electrospray Ionization
4.
J Hazard Mater ; 419: 126422, 2021 10 05.
Article in English | MEDLINE | ID: mdl-34182426

ABSTRACT

The chemical constituents in food contact materials (FCMs) may transfer into food during the contact, which may pose potential risk to humans. So, it is important to evaluate the safety of FCMs. Due to the advantages of cost-effectiveness and high throughput, (Q)SAR tools have been gradually used for risk assessment. In this work, a risk classification strategy for migrants of food contact materials combined with three (Q)SAR tools was developed based on a single endpoint (Mutagenicity) assessment and risk matrix approach, respectively. 419 migrants existing in a self-built toxicology database beneficial from Python crawler technology were evaluated. 5 toxic hazard ranks and 4 risk ranks were obtained for single endpoint assessment and risk matrix respectively, with 21 substances assigned as Toxic hazard Class I and 43 substances assigned as RISK Ⅰ which need the highest safety concern. Besides, for the Toxic hazard Class I substances assessed by the single endpoint, 19 of them were confirmed experimentally, and all of them were overlapped in the RISK Ⅰ substances, which suggests the effectiveness and reliability of this strategy.


Subject(s)
Food Packaging , Mutagens , Computer Simulation , Humans , Mutagenicity Tests , Reproducibility of Results , Risk Assessment
5.
Food Chem ; 364: 130414, 2021 Dec 01.
Article in English | MEDLINE | ID: mdl-34175632

ABSTRACT

Phospholipids play a key role in infant nutrition and cognitive function. In this study, hydrophilic interaction liquid chromatography coupled to quadrupole time-of-flight mass spectrometry method was firstly developed to analyze the composition of phospholipids. Then we characterized and quantified phospholipids extracted from raw, pasteurized, homogenized, and spray-dried milk to investigate the effect of the technological process on the composition of the phospholipids. Results indicate that the composition of the phospholipids underwent minor changes after pasteurization, while the concentration of phospholipids was significantly affected by the spray-drying process, especially phosphatidylethanolamine and phosphatidylinositol. Multivariate data analysis further verified the results and indicated that phospholipids containing polyunsaturated fatty acids had undergone significant changes during the production chain, especially in spray-drying. This work reveals the changes of phospholipids composition during the production chain of infant formulas and serve as a reference for the subsequent optimization of infant formulas to meet nutritional need of infants.


Subject(s)
Infant Formula , Phospholipids , Chromatography, Liquid , Data Analysis , Humans , Infant , Mass Spectrometry
6.
Food Chem ; 345: 128625, 2021 May 30.
Article in English | MEDLINE | ID: mdl-33601649

ABSTRACT

Small molecules in food contact materials may migrate into food during their contact. To extensively analyze the migrants, non-targeted screening is needed to detect the migrants. The migrants' detection is difficult because of the complexity and the trace amount of the migrants. In this work, the dissolution precipitation method was used to extract small molecules in Polyamide (PA) kitchenware. The extract solutions were screened by ultra-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (UPLC-QTOF-MS) for non-targeted analysis and 64 different small molecules in materials were identified through the screening of a self-built database. Then, migration tests were performed to analyze migrants in food simulants. It suggests that the abundance of PA oligomers was the highest in migrants. The risk assessment of migrants revealed that the exposure of most migrants was at a safer level unlike the exposure of PA oligomers that exceeded their threshold of toxicological concern (TTC).


Subject(s)
Food Contamination/analysis , Nylons/analysis , Chromatography, High Pressure Liquid , Food Packaging , Mass Spectrometry/methods , Risk Assessment
7.
AAPS PharmSciTech ; 22(1): 50, 2021 Jan 17.
Article in English | MEDLINE | ID: mdl-33458791

ABSTRACT

Biological activity and pharmacological efficacy of protein drugs may be affected by the compatibility between drug and packaging materials. The compatibility of rubber closures seal cap has become the focus of many studies due to its complicated formulation. Despite of the significance of the issue, currently, there is little available data about organic leachables in drugs which is also not comprehensive. Since the concentration of migrants in drug is usually low and the matrix is complicated, the establishment of overall profile of extractables is crucial for the characterization of leachables. Herein, the supercritical fluid extraction (SFE) method was used because of its great extraction capacity and efficiency for low to medium polar extractables in rubber stoppers. The SFE conditions were optimized by response surface methodology (RSM). Experimental results of the extract yield were close to the predicted values (R2 = 0.95). Then the extractables were qualitatively and quantitatively analyzed with ultrahigh performance liquid chromatography quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS). Finally, risk assessment was made by comparing predicted exposure with injection permitted daily exposure (pPDE) limit or threshold recommended by threshold of toxicological concern (TTC). The results showed that there are many extractables such as glyceride, fatty acids and derivatives, antioxidants, and degradation products. Among them degradation products were in the majority and content of 17 substances exceeded corresponding limits. Considering their unknown toxicology, more experiments are therefore needed to provide information on their toxicology and risk assessment. The study provides a reference for the compatibility of drugs, and quality supervision of pharmaceuticals packaging.


Subject(s)
Chromatography, High Pressure Liquid/methods , Chromatography, Supercritical Fluid/methods , Drug Packaging/methods , Mass Spectrometry/methods , Rubber , Pharmaceutical Preparations
SELECTION OF CITATIONS
SEARCH DETAIL
...