Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(13)2024 Jul 07.
Article in English | MEDLINE | ID: mdl-39001178

ABSTRACT

Wearable resistance training is widely applied to enhance running performance, but how different placements of wearable resistance across various body parts influence running efficiency remains unclear. This study aimed to explore the impacts of wearable resistance placement on running efficiency by comparing five running conditions: no load, and an additional 10% load of individual body mass on the trunk, forearms, lower legs, and a combination of these areas. Running efficiency was assessed through biomechanical (spatiotemporal, kinematic, and kinetic) variables using acceleration-based wearable sensors placed on the shoes of 15 recreational male runners (20.3 ± 1.23 years) during treadmill running in a randomized order. The main findings indicate distinct effects of different load distributions on specific spatiotemporal variables (contact time, flight time, and flight ratio, p ≤ 0.001) and kinematic variables (footstrike type, p < 0.001). Specifically, adding loads to the lower legs produces effects similar to running with no load: shorter contact time, longer flight time, and a higher flight ratio compared to other load conditions. Moreover, lower leg loads result in a forefoot strike, unlike the midfoot strike seen in other conditions. These findings suggest that lower leg loads enhance running efficiency more than loads on other parts of the body.


Subject(s)
Running , Wearable Electronic Devices , Humans , Running/physiology , Male , Pilot Projects , Biomechanical Phenomena , Young Adult , Adult , Resistance Training/methods , Resistance Training/instrumentation
2.
Sports (Basel) ; 12(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38393265

ABSTRACT

Stability during running has been recognized as a crucial factor contributing to running performance. This study aimed to investigate the effects of wearable equipment containing external loads on different body parts on running stability. Fifteen recreational male runners (20.27 ± 1.23 years, age range 19-22 years) participated in five treadmill running conditions, including running without loads and running with loads equivalent to 10% of individual body weight placed on four different body positions: forearms, lower legs, trunk, and a combination of all three (forearms, lower legs, and trunk). A tri-axial accelerometer-based smartphone sensor was attached to the participants' lumbar spine (L5) to record body accelerations. The largest Lyapunov exponent (LyE) was applied to individual acceleration data as a measure of local dynamic stability, where higher LyE values suggest lower stability. The effects of load distribution appear in the mediolateral (ML) direction. Specifically, running with loads on the lower legs resulted in a lower LyE_ML value compared to running without loads (p = 0.001) and running with loads on the forearms (p < 0.001), trunk (p = 0.001), and combined segments (p = 0.005). These findings suggest that running with loads on the lower legs enhances side-to-side local dynamic stability, providing valuable insights for training.

SELECTION OF CITATIONS
SEARCH DETAIL
...