Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
3.
Eur Radiol ; 26(1): 1-8, 2016 Jan.
Article in English | MEDLINE | ID: mdl-25956937

ABSTRACT

OBJECTIVES: To analyze the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) of thyroid nodules. METHODS: Of 3517 CNBs performed using an 18G spring-loaded device in one institution, we retrospectively reviewed 676 nodules in 629 consecutive patients who underwent surgery. CNB and pathological examination were compared. CNB diagnosis was standardized in four categories: insufficient (I), benign (B), follicular lesion (FOL), and malignant (M). Main outcome measures were predictive positive values (PPV), false positives (FP), and false negatives (FN). RESULTS: CNB showed a low rate of insufficient and FOL diagnoses (5.8 % and 4.5 %). On surgery, there were eight FNs in 374 benign CNBs and three FPs in 148 malignant CNBs. The 154 nodules classified as FOL in CNB included, at surgery, 122 neoplasms; 28 of them malignant. PPV for malignancy of a malignant CNB was 98 %, and for a CNB diagnosis of FOL 18.2 %. Sensitivity for malignancy if CNB of FOL and M are considered positive was 95.6. Only one major complication was observed. CONCLUSIONS: CNB is reliable, safe, and accurate to evaluate thyroid nodules and can be an alternative technique to FNA. It has low rate of non-diagnostic and undetermined cases, with high sensitivity and PPV. KEY POINTS: Thyroid core-needle biopsy (CNB) has high sensitivity and PPV. Pitfalls of CNB are rare. Pitfalls are due to cystic cancer, histological heterogeneity, and mistakes in analysis. CNB is a reliable, safe, and accurate method to approach thyroid nodules. CNB can be used primarily or after insufficient or indeterminate FNA.


Subject(s)
Thyroid Neoplasms/pathology , Thyroid Nodule/pathology , Biopsy, Fine-Needle/methods , Biopsy, Large-Core Needle/methods , Female , Humans , Image-Guided Biopsy , Male , Middle Aged , Retrospective Studies , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/surgery , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/surgery , Ultrasonography, Interventional/methods
4.
Eur Urol ; 57(3): 459-65, 2010 Mar.
Article in English | MEDLINE | ID: mdl-19926208

ABSTRACT

BACKGROUND: Radiofrequency ablation (RFA) is a minimally aggressive, therapeutic alternative for renal tumors. It can be an alternative to nephrectomy in patients with previous nephrectomy, bilateral tumors, von Hippel-Lindau disease, or small renal carcinomas and in those with contraindications for surgery. OBJECTIVE: To assess the effectiveness of the treatment of renal tumors by RFA in the short and medium term and to identify the possible complications and the factors that determine therapeutic success. DESIGN, SETTING, AND PARTICIPANTS: A retrospective review of patients with renal tumors treated with RFA between May 2005 and December 2008 was performed in a tertiary academic hospital. Patients were selected among those with previous nephrectomy, bilateral neoplasms, von Hippel-Lindau disease, surgical risk, comorbidity, advanced age, or patient's refusal to surgery. Tumors with evidence of extrarenal extension were excluded. Patients were followed up for 10-50 mo using computed tomography and magnetic resonance imaging. INTERVENTION: Ultrasound-guided RFA was performed on 65 tumors (range: 1.2-5.3 cm) of 58 patients using multitined electrodes. MEASUREMENTS: Incomplete ablation rate, therapeutic success rate, and complications rate. RESULTS AND LIMITATIONS: Therapeutic success was achieved in 59 of 65 tumors (91%): 53 in a single session, 5 in two sessions, and 1 in three sessions. A significant relationship was observed between size and growth pattern of the tumor and both therapeutic success and incomplete ablation rates. Therapeutic success in tumors >5 cm was 60%. Complications were detected in 10 patients (13%); 5% were considered major complications. Limitations include the lack of pathologic studies to confirm a complete ablation and the lack of a control group to compare with the results of those who underwent nephrectomy. CONCLUSIONS: RFA is safe and effective in renal tumors. Corticomedullary lesions and tumors >3 cm have greater possibility of incomplete ablation. In tumors >5 cm, RFA has a significant failure rate.


Subject(s)
Catheter Ablation/instrumentation , Catheter Ablation/methods , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/surgery , Adult , Aged , Aged, 80 and over , Catheter Ablation/adverse effects , Electrodes/adverse effects , Equipment Design , Female , Humans , Male , Middle Aged , Retrospective Studies , Time Factors , Ultrasonography
5.
Can Assoc Radiol J ; 60(5): 263-72, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19931132

ABSTRACT

Calcific tendinitis is caused by the pathologic deposition of calcium hydroxyapatite crystals in tendons and is a common cause of joint pain. The disease typically affects the shoulder and hip, with characteristic imaging findings; however, any joint can be involved. Occasionally, calcific tendinitis can mimic aggressive disorders, such as infection and neoplasm, especially on magnetic resonance imaging. Radiologists should be familiar with the imaging findings to distinguish calcific tendinitis from more aggressive processes. Image-guided percutaneous needle aspiration and steroid injection of calcific tendinitis are useful techniques performed by the radiologist for the treatment of symptomatic cases. Familiarity with these procedures and their imaging appearance is an important aspect in the management of this common disease.


Subject(s)
Calcinosis/diagnostic imaging , Tendinopathy/diagnostic imaging , Finger Joint/diagnostic imaging , Foot/diagnostic imaging , Hip Joint/diagnostic imaging , Humans , Shoulder Joint/diagnostic imaging , Tendons/diagnostic imaging , Tomography, X-Ray Computed/methods , Wrist Joint/diagnostic imaging
7.
Emerg Radiol ; 14(6): 403-9, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17653779

ABSTRACT

To assess the reliability of indirect computed tomography venography (CTV) in the detection of deep venous thrombosis (DVT) in patients with clinical suspicion of pulmonary embolism (PE). 235 consecutive patients with suspicion of PE underwent an imaging protocol composed of a CT pulmonary angiography (CTPA), a CTV and an ultrasound study of the deep venous system, which was considered the "gold standard." Sensitivity, specificity, and predictive values were calculated for CTV. ith CTV, 30 (12.8%) cases of DVT were detected, 9 (3.8%) of them without pulmonary embolism in CTPA, increasing the diagnosis of thromboembolic disease in 3.8%. However, six of these nine diagnoses were false positives, and CTV missed six cases of DVT. CTV rendered a sensitivity of 58.8%, specificity of 95.0%, a positive predictive value of 66.7%, and a negative predictive value of 93.2%. In patients with clinical suspicion of pulmonary embolism, ultrasound is preferred to CTV for the detection of DVT.


Subject(s)
Angiography/methods , Pulmonary Embolism/diagnostic imaging , Thromboembolism/diagnostic imaging , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Contrast Media , Female , Humans , Iohexol , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Pulmonary Embolism/etiology , Sensitivity and Specificity , Thromboembolism/complications , Ultrasonography
8.
APMIS ; 114(7-8): 492-9, 2006.
Article in English | MEDLINE | ID: mdl-16907854

ABSTRACT

Core biopsy has not traditionally been recommended in the study of spleen nodules due to the supposed fragility of this organ leading to a high risk of post-core biopsy complications. A total of 13 patients who presented solid spleen nodules, diffuse splenomegaly, or both on imaging studies (CT, MR, US) were biopsied under ultrasound control with 18G BioPince needles. Cytological (imprints and cytocentrifugates) and histological material were obtained for diagnosis in every case. Malignant lymphomas were the most commonly found pathology (four diffuse large B-cell lymphomas, two follicular lymphomas, one Hodgkin's disease, one B-cell lymphoma, NOS). In addition, there was one littoral-cell angioma, one well-differentiated neuroendocrine carcinoma, metastatic, and one haemangioma. The remaining two cases showed congestive features, and supposed spleen involvement by lymphoma in one of them was ruled out. On follow up, there were no complications related to the core biopsy. Splenectomy was performed in six cases, two diagnostic and four therapeutic. We conclude that core biopsy is a safe and efficient method in the diagnosis of spleen nodules that could be considered in the routine diagnostic algorithm of these lesions.


Subject(s)
Spleen/diagnostic imaging , Spleen/pathology , Splenic Neoplasms/diagnostic imaging , Splenic Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Biopsy, Needle , Female , Humans , Male , Middle Aged , Ultrasonography
9.
APMIS ; 113(5): 353-60, 2005 May.
Article in English | MEDLINE | ID: mdl-16011662

ABSTRACT

Ultrasound-guided needle biopsy is a safe and efficient diagnostic method increasingly used in the initial approach to superficial and deep musculoskeletal tumours. However, so far no general consensus has been reached regarding its reliability. During a 6-year period (1999-2004), biopsies were taken from 188 patients (100 females, 88 males; age average 55.8 years) with musculoskeletal tumours under ultrasound guidance using 18G BioPince or 14G ProMag 2.2 true-cut type needles. Cytological (imprints and cytocentrifugates) and histological material was obtained for diagnosis in every case. The lower extremity (59 cases) and the abdominal wall (29 cases) were the most commonly affected sites. Benign/reactive tumours (77 cases), metastatic epithelial malignancies (40 cases), and sarcomas (36 cases) were most frequently diagnosed. In 180 (95.75%) cases, core needle results were concordant with the definitive diagnosis (97 true positives and 83 true negatives). Relevant diagnostic discordance was seen in 8 (4.25%) cases (8 false negatives and 0 false positives). Sensitivity, specificity and positive and negative predictive values were 92%, 100%, 100%, and 91%, respectively. Ultrasound-guided core biopsy is thus a useful method in the initial approach to musculoskeletal tumours that allows correct patient management in the vast majority of cases.


Subject(s)
Biopsy, Needle/methods , Bone Neoplasms/diagnostic imaging , Bone Neoplasms/pathology , Muscle Neoplasms/diagnostic imaging , Muscle Neoplasms/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Humans , Male , Middle Aged , Muscle, Skeletal/pathology , Ultrasonography
10.
AJR Am J Roentgenol ; 184(6): 1788-94, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15908531

ABSTRACT

OBJECTIVE: The objectives of our study were to investigate differences in Doppler sonography features between benign and malignant breast lesions and between malignant lesions with different prognostic factors and to propose diagnostic criteria for Doppler sonography of breast lesions. SUBJECTS AND METHODS: We performed power and duplex Doppler sonography examinations in 826 breast lesions scheduled for sonographically guided core needle biopsy. Lesion vascularity, pulsatility index (PI), and resistive index (RI) of the vessels detected were analyzed and correlated with histologic results. RESULTS: Color flow was more frequently seen in malignant (237/348 lesions, 68%) than in benign (171/478, 36%) lesions (p < 0.001). However, sensitivity, specificity, and positive and negative predictive values for this sign were low (68%, 64%, 58%, and 73%, respectively). The RI and PI values were significantly higher (p < 0.001) in cancers. Although an overlap in these values between benign and malignant lesions was observed, all but one nodule with an RI of greater than 0.99 (those with null or inverted diastolic flow) or a PI of greater than 4 were malignant. No significant relationship was found between PI, RI, or flow visualization on power Doppler sonography and tumor grade or lymph node involvement in cancers. CONCLUSION: Flow visualization on power Doppler sonography indicates a higher possibility of malignancy but is not useful as the main sign for malignancy. However, any lesion with a vessel that has an RI value greater than 0.99 or a PI value greater than 4 within it must be considered as probably malignant regardless of any other sonography sign present. Doppler findings are not useful to predict tumor grade or lymph node involvement.


Subject(s)
Breast Neoplasms/diagnostic imaging , Adult , Aged , Biopsy, Needle , Breast/blood supply , Breast/pathology , Breast Neoplasms/blood supply , Female , Humans , Middle Aged , Neovascularization, Pathologic , Predictive Value of Tests , Prognosis , Prospective Studies , Sensitivity and Specificity , Ultrasonography, Doppler , Ultrasonography, Mammary
SELECTION OF CITATIONS
SEARCH DETAIL
...