Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Orthop Surg Traumatol ; 34(2): 1183-1192, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38006463

ABSTRACT

PURPOSE: To determine the survival and patient-reported outcomes in non-oncological patients treated with proximal femoral resection (PFR) using MEG for femoral reconstruction. MATERIALS AND METHODS: This retrospective study included 16 patients. Demographic variables and complications developed were analyzed. Clinical-functional outcomes were measured using the modified Harris score (mHSS), numeric Pain Rating Scale (NPRS) and Musculoskeletal Tumor Society (MSTS) score. MEG survival was estimated using a Kaplan-Meier survival analysis. RESULTS: Average follow-up was 5 years (range, 1-9). The 75% of patients were overweight and women with an average age of 74.2 ± 5.9-years (BMI of 28.5 ± 4.2 kg/m2). The main cause of MEG was periprosthetic infection (43.7%). The 50% of patients had post-surgical complications regarding with MEG, being the most frequent seromas and MEG dislocation. Implant survival was 93.4% and 80.9% at 3 and 7 years of follow-up, respectively. The functional results at the end of the follow-up with respect to the pre-surgical state improved from 9.5 ± 2.6 to 3 ± 0.9 mean NPRS and 26.5 ± 6.8 to 69.5 ± 13.5 mean mHHS, p < 0.001, respectively. The mean MSTS score was 68.1% that these results were considered excellent. CONCLUSIONS: The MEG for reconstruct III-IV femoral defects is a good therapeutic option that offers an acceptable clinical-functional result. Short-term and medium-term survival was greater than 80%. The most frequent complications are seromas and MEG dislocation. The use of constrained liner and abductor system reconstruction is essential to prevent the dislocation.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Female , Aged , Aged, 80 and over , Prosthesis Design , Follow-Up Studies , Retrospective Studies , Seroma/pathology , Seroma/surgery , Treatment Outcome , Prosthesis Failure , Femur/pathology , Reoperation , Arthroplasty, Replacement, Hip/methods
2.
Arch Orthop Trauma Surg ; 144(1): 347-355, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37743356

ABSTRACT

INTRODUCTION: Few information has been published on the survival of unicompartmental knee arthroplasty (UKA) and fixed-bearing tibial components. The aim of this study is to analyze if UKA survival varies according to UKA model used and to analyze the possible risk factors for UKA revision. MATERIALS AND METHODS: A retrospective study analyzing 301 UKAs (ACCURIS, all-polyethylene tibial component, 152; Triathlon PKR, metal-backed tibial component, 149) was performed. Demographic parameters as well as implant survival and cause of prosthetic revision were analyzed. The Kaplan-Meier survival analysis, the log-rank test and the Cox multiple regression were used for the analysis. RESULTS: Average follow-up was 8.1 ± 3.08-years. Average age was 68.1 ± 8.6-years; 70.4% of subjects were women. The ACCURIS UKA group had a UKA revision rate higher compared to the Triathlon PKR group (16/152, 10.6% vs 5/149, 3.4%, respectively; p < 0.001). The main cause of prosthetic revision was aseptic loosening (5/21, 23.8%). All aseptic loosening cases and tibial component collapse were reported with the ACCURIS UKA group. Overall UKA survival was 98.01% (95% CI 95.62-99.1) at 1-year, 94.27% (95% CI 90.95-96.4) at 5-years and 92.38% (95% CI 88.48-94.99) at 10-years' follow-up. There were no differences in the Kaplan-Meier survival curves regarding operated side or affected tibiofemoral compartment (log-rank test = 0.614 and 0.763, respectively). However, Kaplan-Meier survival curve according to UKA model used was different (log-rank test = 0.033). The metal-backed component appeared to be a protector factor for UKA revision when adjusted for age, sex, operated side, and affected tibiofemoral compartment (Hazard Ratio 0.32, p = 0.031). CONCLUSION: Fixed-bearing UKAs showed excellent mid- and long-term survival rates. Aseptic loosening is the main cause of implant failure. PKR group (metal-backed component) seem to be a protector factor to UKA revision when it was compared with ACCURIS UKA group (all-polyethylene tibial component).


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Female , Middle Aged , Aged , Male , Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Retrospective Studies , Reoperation/adverse effects , Prosthesis Failure , Polyethylene , Metals , Osteoarthritis, Knee/surgery , Treatment Outcome , Knee Joint/surgery
3.
Arch Orthop Trauma Surg ; 142(8): 2093-2101, 2022 Aug.
Article in English | MEDLINE | ID: mdl-34302520

ABSTRACT

INTRODUCTION: Short stems seem to be a good alternative for young patients as they offer promising results, rapid recovery and preservation of metaphyseal bone stock. This is one of the few studies in the literature to report medium-term clinical-radiological results for short hip stems. MATERIALS AND METHODS: This prospective study evaluated 68 short femoral stems in 63 patients treated with total hip replacement. Clinical, functional and quality-of-life outcomes were measured at 6 and 12 months, and annually thereafter until the end of follow-up. The radiological analysis included measurements of potential leg length discrepancies, stem alignment and signs compatible with stress shielding. RESULTS: Fifty-four males (59 hips) and nine females (9 hips) of an average age of 44.3 years (range, 25-68) were studied. The most common diagnosis was osteoarthritis (51.5%). Mean overall follow-up was 7.8 years (range, 5.8-9.8). The overall survival rate was 97.1% (95% CI 88.7-99.7%). Surgery resulted in an increase of 42.3 ± 1.1 points in the modified Harris Hip Score and 21.9 ± 0.6 points in the Oxford Hip Score (p < 0.001, respectively). Moreover, the pain score as measured on a numerical rating scale (NRS) improved from 95.8 to 36.3. As regards function, an improvement was observed from 3.2 ± 0.8 points to 6.8 ± 1.14 points on the University of California at Los Angeles activity score (p < 0.001, respectively). The radiological analysis showed an absence of radiolucencies or stress-shielding throughout the series. The complications rate at the end of follow-up was 5.7%. CONCLUSIONS: The use of ultra-short cylindrical stems with complete anchorage in the femoral neck was shown to offer promising medium-term results. Such stems appear to be a good option for young patients, who are likely to require several revisions over their lifetime.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Adult , Arthroplasty, Replacement, Hip/adverse effects , Female , Follow-Up Studies , Humans , Male , Prospective Studies , Prosthesis Design , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...