ABSTRACT

Results from a novel ion selective electrode (ISE) for ionized magnesium (Mg2+) correlate well with atomic absorption spectroscopy on aqueous solutions containing from 0.1-3.0 mmol MgCl2/L. Day to day precision (coefficient of variation) of the electrode on protein-based controls is < 4%; aqueous-based controls < 6%. The new ISE is selective for Mg2+ with a selectivity constant for Ca2+ (KMgCa) of 8 x 10(-2). Adding pathophysiologic concentrations of Cd2+, Ca2+, Cu2+, Fe3+, K+, Na+, or Zn2+ to serum and aqueous solutions gave negligible to minimal changes in measured Mg2+. Ligand binding studies in aqueous solution indicate that pathophysiologic concentrations of different anions (e.g. heparin, lactate, bicarbonate, phosphate, acetate and sulfate) bind to Mg2+, effectively reducing its concentration in solution. Likewise, silicon (as either found in Vacuutainer tubes or as chlorosilane) failed to exert any significant effect on measured Mg2+. Addition of Intralipid (up to 500 mg/dL) gave negligible to minimal changes in Mg2+. Mg2+ measurements on whole blood, plasma, and serum for a given human subject's samples are virtually identical, at least within the reference range for Mg2+. Typically, Mg2+ is 71% of TMg, but varies from subject to subject; i.e. Mg2+ cannot be predicted from TMg. Clinical studies revealed that the Mg2+/TMg ratio could be remarkably consistent in sequential samples (e.g., throughout the course of coronary bypass surgery) taken from one patient, but that this ratio could differ dramatically from the ratio in sequential samples taken from another. Mg2+ is held within a narrow range (0.53-0.67 mmol/L) in normal, healthy subjects when compared to TMg (0.70-0.96 mmol/L).


Subject(s)
Ion-Selective Electrodes , Magnesium/analysis , Adult , Aged , Aged, 80 and over , Calcium/analysis , Cardiopulmonary Bypass , Cations , Humans , Hydrogen-Ion Concentration , Ion-Selective Electrodes/statistics & numerical data , Magnesium/blood , Middle Aged , Quality Control , Reference Values , Sensitivity and Specificity , Spectrophotometry, Atomic , Water
2.
Methods Find Exp Clin Pharmacol ; 14(4): 297-304, 1992 May.
Article in English | MEDLINE | ID: mdl-1507932

ABSTRACT

A novel ion selective electrode (ISE) for ionized magnesium (IMg2+) in whole blood (WB), plasma (PL) and serum (S) has now been designed and characterized in normal human subjects, diseased and pregnant subjects. Using this ISE on various levels of aqueous Mg2+ solutions (0.1-3.0mM), mean Mg2+ values are within 94.6 and 99.2% of their targets. The linearity of the ISE (0.1-3.0mM) in aqueous solution and human PL and S ranges between 92.0 and 99.3%. The ISE is highly selective for IMg2+, yielding measurements in less than 2 min, and exhibiting no or negligible effects from physiologic concentrations of Ca2+,Na+,K+ or H+. Ligand binding studies indicate that pathophysiologic concentrations of most smaller molecular weight anions fail to interfere with IMg2+ measurements in aqueous solution, PL or S. Likewise, pathophysiologic concentrations of heavy metals or lipids do not interfere with measurements for IMg2+. Comparison of healthy, normal WB, PL and S IMg2+, using the ISE, with measurements of ultrafilterable Mg by atomic absorption spectroscopy (AAS) are excellent. The mean value for IMg2+ in normal WB, PL and S is 0.58-0.60mM (range = 0.53-0.67mM). Compared to total Mg (TMg) (0.75-0.96mM) and ICa2+ (1.10-1.30mM), IMg2+ is held in a narrow, tight range, representing 71% of TMg. Preliminary studies on plasma and serum IMg2+ during open heart surgery and term pregnancy demonstrate significant abnormalities in IMg2+ and % IMg2+. The new ISE for IMg2+ should prove invaluable and revolutionary in studies of Mg metabolism in both healthy and diseased states.


Subject(s)
Magnesium/blood , Plasma/chemistry , Adult , Aged , Aged, 80 and over , Cardiopulmonary Bypass , Female , Humans , Labor, Obstetric/blood , Male , Middle Aged , Pregnancy , Ultrafiltration