Heliyon ; 10(6): e28142, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38533048

ABSTRACT

Rationale and objectives: Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). Methods: CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated. Additionally, readers had to assign the scans to reduced or regular CMD. Regions-of-interest (ROIs) were placed in defined segments of portal vein, inferior vena cava, liver, spleen, kidneys, abdominal aorta and muscular tissue. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Results: Overall 158 CT scans performed on a PCD-CT and 68 examinations on an EID-CT were analyzed. Overall diagnostic quality showed no significant differences for PCD-CT with standard CMD which scored a median 5 (IQR:5-5) and PCD-CT with 70% CMD scoring 5 (4-5). (For PCD-CT, 71.69% of the examinations with reduced CMD were assigned to regular CMD by the readers, for EID-CT 9.09%. Averaged for all measurements SNR for 50% CMD was reduced by 19% in PCD-CT (EID-CT 34%) and CNR by 48% (EID-CT 56%). Virtual monoenergetic images (VMI)50keV for PCD-CT images acquired with 50% CMD showed an increase in SNR by 72% and CNR by 153%. Conclusions: Diagnostic interpretability of PCD-CT examinations with reduction of up to 50% CMD is maintained. PCD-CT deducted scans especially with 70% CMD were often not recognized as CMD reduced scans. Compared to EID-CT less decline in SNR and CNR is observed for CMD reduced PCD-CT images. Employing VMI50keV for CMD-reduced PCD-CT images compensated for the effects.

2.
Sci Rep ; 14(1): 497, 2024 01 04.
Article in English | MEDLINE | ID: mdl-38177651

ABSTRACT

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV: - 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans.


Subject(s)
Dental Implants , Artifacts , Retrospective Studies , Tomography, X-Ray Computed/methods , Cheek , Signal-To-Noise Ratio , Radiographic Image Interpretation, Computer-Assisted/methods
3.
J Clin Med ; 12(18)2023 Sep 12.
Article in English | MEDLINE | ID: mdl-37762868

ABSTRACT

Uterine fibroids are the most common benign tumors of the uterus. Approximately 20-50% of women with myomas experience a variety of symptoms such as vaginal bleeding, abdominal pain, pelvic pain and pressure, and urological problems, possibly interfering with fertility and pregnancy. Although surgery remains the standard treatment option for fibroids, non-invasive therapeutic options, such as high-intensity focused ultrasound (HIFU), have emerged over the last dec ade. During HIFU, ultrasound is focused on the target tissue causing coagulation necrosis. HIFU has, meanwhile, become an established method for treating uterine fibroids in many countries. Clinical data have shown that it effectively alleviates fibroid-related symptoms and reduces fibroid size with a very low rate of side effects. However, there is a lack of data on how this treatment affects laboratory parameters and structural features of uterine tissue. As our center is the only one in German-speaking countries where ultrasound-guided HIFU technology is currently established, the aim of this prospective, monocentric, single-arm trial is not only to evaluate the safety and efficacy of local US-guided HIFU in symptomatic uterine fibroid patients according to GCP standards but also to explore its effects on blood parameters and the structural integrity of uterine tissue using elastographic methods.

4.
Sci Rep ; 13(1): 8955, 2023 06 02.
Article in English | MEDLINE | ID: mdl-37268675

ABSTRACT

Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100-190 keV with and without IMAR, and compared to polychromatic images. Qualitatively, artifact extent and assessment of adjacent soft tissue were rated by two radiologists using 5-point Likert items. Quantitative assessment was performed measuring attenuation and standard deviation in most pronounced hypodense and hyperdense artifacts, artifact-impaired bone, muscle, vessels, bladder and artifact-free corresponding tissue. To quantify artifacts, an adjusted attenuation was calculated as the difference between artifact-impaired tissue and corresponding tissue without artifacts. Qualitative assessment improved for all investigated image reconstructions compared to polychromatic images (PI). VMI100keV in combination with IMAR achieved best results (e.g. diagnostic quality of the bladder: median PI: 1.5 (range 1-4); VMI100keV+IMAR: 5 (3-5); p < 0.0001). In quantitative assessment VMI100keV with IMAR provided best artifact reduction with an adjusted attenuation closest to 0 (e.g. bone: PI: 302.78; VMI100keV+IMAR: 51.18; p < 0.0001). The combination of VMI and IMAR significantly reduces hip prosthesis-associated artifacts in PCD-CT and improves the diagnostic quality of surrounding tissue.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Retrospective Studies , Metals , Tomography, X-Ray Computed/methods , Artifacts , Algorithms
5.
Radiologie (Heidelb) ; 63(7): 497-506, 2023 Jul.
Article in German | MEDLINE | ID: mdl-37289254

ABSTRACT

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a CT technology that overcomes many limitations of conventional detectors. Direct conversion of photons hitting the detector into electrical signals combined with more sensitive and accurate photon detection simultaneously allows spectral evaluation and also potential reduction in radiation exposure to the patient. The combination of energy thresholds and elimination of detector septa allows for a reduction of electronic noise, an increase of spatial resolution, and an improvement of dose efficiency. ACHIEVEMENTS: Recent research has confirmed significantly reduced image noise, reduced radiation dose, increased spatial resolution, improved iodine signal, and a reduction in artifacts. Spectral imaging potentiates these effects and also allows retrospective calculation of virtual monoenergetic images, virtual noncontrast images or iodine maps. Thus, the photon-counting technique offers the possibility of using various contrast agents, with the prospect of single-scan multiphase imaging or visualization of specific metabolic processes. Therefore, further research and complementary approval processes are necessary for clinical application. Likewise, further research is needed to develop and validate optimal settings and reconstructions for a wide variety of situations, as well as to test new application possibilities. CONCLUSIONS: The only photon-counting detector CT device available on the market to date received clinical approval in 2021. It remains to be seen which other applications will become possible through improvements in hardware and software. This technology has already demonstrated an impressive superiority compared with the current standard of CT imaging, especially regarding high-resolution imaging of detailed structures and examinations with high radiation exposure.


Subject(s)
Iodine , Tomography, X-Ray Computed , Humans , Retrospective Studies , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Contrast Media
6.
Cardiovasc Intervent Radiol ; 46(5): 658-663, 2023 May.
Article in English | MEDLINE | ID: mdl-36826490

ABSTRACT

PURPOSE: To investigate and compare the physical properties of the new generation Gore VIATORR-Controlled Expansion Endoprosthesis (VCX) to those of the predecessor VIATORR stent in an in vitro experimental setup. MATERIALS AND METHODS: A total of 12 stents (8 VCX; 4 VIATORR; GORE, USA) were examined. Radial resistive force (RRF) and chronic outward force (COF) were assessed using a radial force testing machine (RX-650, Machine Solutions Inc., USA). To assess the radial forces of the VCX above 8 mm, balloon expansion was performed between cycles. RESULTS: All VCX stents show an abrupt decrease in COF at an external diameter of 8.3 mm; RRF decreases likewise at an external diameter of 8.5 mm. The predecessor VIATORR stent without the "controlled expansion" feature shows linear radial force reduction until full expansion at a diameter of 10 mm. The physical properties of the VCX can be altered by balloon modulation. Point of COF (RRF) reduction shifts to 8.5 mm (8.6 mm), 8.6 mm (8.8 mm) and 9.3 mm (9.6 mm) following modulation with a 8 mm, 9 mm and 10 mm balloon. CONCLUSIONS: The VCX shows an abrupt and disproportionate decrease in COF and RRF at an external diameter of 8.3 mm, thus passive expansion to its nominal diameter of 10 mm is not to be expected. By means of balloon dilatation the physical properties of the stent can be altered, enabling customized TIPS creation. The previous VIATORR stent shows continuous COF and RRF until total expansion.


Subject(s)
Portasystemic Shunt, Transjugular Intrahepatic , Humans , Stents , Prosthesis Design
7.
Radiologie (Heidelb) ; 63(1): 30-37, 2023 Jan.
Article in German | MEDLINE | ID: mdl-36413258

ABSTRACT

BACKGROUND: A variety of transhepatic percutaneous biliary procedures are appropriate for the treatment of pathologies of the biliary system. OBJECTIVES: The aim of this article is to describe best practices for performing percutaneous transhepatic cholangiography with placement of a biliary drain (PTCD), percutaneous transhepatic removal of bile duct stones, percutaneous stenting of the bile ducts, and percutaneous treatment of postoperative bilioma. MATERIALS AND METHODS: The authors reviewed existing literature on relevant current recommendations and presented them based on their own facility's approach. RESULTS: Biliary interventions are mostly aimed at treating some form of cholestasis of benign or malignant etiology. The technical success rate is up to 90%. CONCLUSION: Percutaneous biliary interventions are safe and effective procedures in the treatment of pathologies of the biliary system, preferably used when endoscopic access is not possible due to anatomical conditions.


Subject(s)
Cholestasis , Drainage , Humans , Drainage/adverse effects , Drainage/methods , Bile Ducts , Cholangiography/adverse effects , Cholestasis/diagnostic imaging , Cholestasis/etiology , Cholestasis/surgery , Endoscopy/adverse effects
8.
CVIR Endovasc ; 5(1): 28, 2022 Jun 22.
Article in English | MEDLINE | ID: mdl-35731309

ABSTRACT

PURPOSE: To report the safety and efficacy of percutaneous transfemoral venous recanalization of occluded intrahepatic portosystemic stents (TIPS) in cases where the transjugular approach is not feasible. MATERIALS AND METHODS: Between 2000 and 2020, 8 patients with occluded TIPS underwent recanalization via a percutaneous transfemoral venous access. Prior recanalization via a typical transjugular approach was attempted in all cases. Primary technical success was defined as successful crossing of the occlusion. Secondary technical success was defined as the rate of successful TIPS recanalization. Periprocedural complications were evaluated to assess procedural safety. RESULTS: In 8/8 patients transfemoral venous TIPS recanalization was successful. No procedure-related complications were observed. CONCLUSIONS: The transfemoral venous approach is a safe and efficient alternative for TIPS recanalization in cases where the transjugular approach is not feasible.

9.
Biomedicines ; 10(5)2022 May 21.
Article in English | MEDLINE | ID: mdl-35625930

ABSTRACT

To evaluate the embolic properties of different acrylic adhesive/iodized oil mixtures for lymphatic interventions. Polymerization of histoacryl (HA) (Bayer Healthcare) and glubran 2 (GL) (GEM) mixed with iodized oil (ratios 1:0-1:7) were investigated in lymphatic fluids with low and high triglyceride (low TG & high TG) contents. Static polymerization time and dynamic polymerization experiments with different volumes of glucose flush (1, 2 and 5 mL) were performed to simulate thoracic duct embolization. For both glues, static polymerization times were longer when the iodized oil content was increased and when performed in high TG lymphatic fluid. In the dynamic experiments, the prolongation of polymerization due to the oil content and TG levels was less pronounced for both glue types. Increased lymphatic flow rates decreased embolization times for low glue/oil ratios while preventing embolization for high glue/oil ratios. Higher glucose flush volumes increased occlusion times. Polymerization times of acrylic glue in a lymphatic fluid are prolonged by increasing the iodized oil concentration and triglyceride concentration as well as by using larger volumes of glucose flush. Increased lymphatic flow rates decrease embolization times for low glue/oil ratios and may prevent embolization for high glue/oil ratios.