Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Ann Vasc Surg ; 59: 119-126, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31034950

ABSTRACT

BACKGROUND: Acute type B aortic dissection (AoD) with malperfusion is a rare and complex disease. In this specific setting, invasive treatment is generally required to improve aortic branch vessel flow. Thoracic aorta stent grafting (TEVAR) of the proximal descending thoracic aorta to cover/exclude the proximal intimal entry tear would promote resolution of the dynamic component (the most prevalent) of the malperfusion conflict by redirecting the flow within the true lumen. The aim was to study outcomes of patients undergoing TEVAR for acute (<14 days) type B AoD complicated with malperfusion and to depict any preoperative and intraoperative predictors that could affect the prognosis of those patients. METHODS: From March 2005 to January 2016, all patients treated with TEVAR for acute type B AoD with malperfusion in 2 European high-volume aortic centers were retrospectively studied. Preoperative, intraoperative, and postoperative details were collected. Preoperative computed tomography angiogram was reanalyzed on a dedicated 3D workstation (Aquarius iNtuition Viewer, TeraRecon). Thirty-day malperfusion-related complication and mortality rates were determined. Logistic regression model was used to assess preoperative and intraoperative factors affecting postoperative outcomes; in particular, details on the mechanisms of malperfusion and organ(s) involved were entered into the model and tested. RESULTS: A total of 41 patients (60 years old [interquartile range (IQR): 51-68.5]; 78% men) have been included in the analysis. Patients were mostly (68.3%) affected by only 1 malperfusion syndrome, with renal ischemia being the most frequent (53.6%). The median length of aortic coverage was 197 mm (IQR: 157-209). Additional visceral/renal/iliac stentings were performed after stent graft implantation for 25 branches in 17 patients (41%). The 30-day mortality rate was 17.1%. All but 2 early deaths were related to malperfusion. The number of malperfusion syndromes was the only independent factor associated to increasing 30-day malperfusion-related complications or deaths (3 vs 1, HR = 30.3 [P = 0.001]; 3 vs 2, HR = 9.9 [P = 0.004]). CONCLUSIONS: Prognosis of patients with acute type B AoD complicated initially with malperfusion syndrome(s) is severe, especially if several territories are ischemic. Early identification of those complications can be lifesaving but still lacks hard criteria.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Ischemia/etiology , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/physiopathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Computed Tomography Angiography , Endovascular Procedures/instrumentation , Female , France , Hospitals, High-Volume , Humans , Ischemia/diagnostic imaging , Ischemia/physiopathology , Male , Middle Aged , Regional Blood Flow , Retrospective Studies , Risk Assessment , Risk Factors , Stents , Sweden , Time Factors , Treatment Outcome
2.
Eur J Vasc Endovasc Surg ; 55(4): 504-510, 2018 04.
Article in English | MEDLINE | ID: mdl-29501401

ABSTRACT

OBJECTIVES: To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. DESIGN: This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. METHODS: Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). RESULTS: Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). CONCLUSIONS: BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is required to confirm these promising results.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Computed Tomography Angiography , Databases, Factual , Endoleak/etiology , Endovascular Procedures/adverse effects , Female , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , Male , Prospective Studies , Prosthesis Design , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Duplex , Vascular Patency
3.
J Vasc Surg ; 67(3): 685-693, 2018 03.
Article in English | MEDLINE | ID: mdl-29153441

ABSTRACT

OBJECTIVE: We report our experience of the treatment of postdissection arch aneurysms and thoracoabdominal aortic aneurysms (TAAAs) by endovascular repair using fenestrated and branched endografts. METHODS: This study includes all patients presenting with chronic postdissection aneurysms >55 mm in diameter deemed unfit for open surgery and treated by complex endografting between October 2011 and April 2017. Where appropriate, staged management strategies including left subclavian artery revascularization, thoracic endografting, dissection flap fenestration, and tear enlargement were performed before the complex endovascular repair. Outcome data were collected prospectively, specifically including technical success, endoleaks, target vessel patency, aneurysm diameter, adverse events, reinterventions, and mortality. RESULTS: We treated 40 patients with a median age of 63 years (55-71 years). In total, 43 procedures were performed: 19 arch repairs using inner branch endografts (one to three branches) and 24 TAAA repairs using fenestrated or branched endografts. Three patients were treated using both arch and TAAA repair. The median time between initial presentation with acute dissection and the first complex aortic repair was 5 years (3.0-10.0 years). Staged procedures were performed in 33 of 40 patients (82.5%). The technical success rate was 93%, the median procedure length was 240 minutes (170-285 minutes), and the median dose-area product was 80 Gy · cm2 (54.3-138.4 Gy · cm2). The 30-day and in-hospital mortality rates were 2.3% (1/43) and 4.7% (2/43), respectively. The spinal cord ischemia rate was 7% and occurred only after TAAA repair. One stroke with partial recovery and one transient ischemic attack were observed (4.7%) after arch repair. Six early reinterventions (14%) were performed: three for access complications, two to treat acute hemorrhage, and one to treat a type II endoleak. Median follow-up was 25.5 months (11-42.25 months). The 1- and 5-year survival rates were 90% and 76.4%, respectively. Late reinterventions were required in eight patients, two in the arch group (to treat endoleaks at 3 and 33 months) and six in the TAAA group (2 iliac and 1 bifurcated endograft extensions, 2 additional renal stents, 1 inferior mesenteric artery embolization). Aneurysm diameter was stable (72%) or shrank (23%) during follow-up. Enlargement was shown in two patients with endoleaks. CONCLUSIONS: Complex endovascular repair of postdissection aneurysms is a safe procedure in patients deemed unfit for open surgery. Our experience suggests that close follow-up is mandatory as secondary procedures are frequently required to completely exclude the false lumen.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Postoperative Complications/mortality , Postoperative Complications/therapy , Prosthesis Design , Retrospective Studies , Risk Factors , Stents , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...