Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rapid Commun Mass Spectrom ; 20(5): 771-6, 2006.
Article in English | MEDLINE | ID: mdl-16470672

ABSTRACT

The development of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of 16 mycotoxins possibly related to the 'Sick Building Syndrome' on filters and in fungal cultures is described. Fungi-surface sampling as regards the 'Sick Building Syndrome' preferably happens by scraping off fungal material and vacuuming onto cellulose filters. Therefore, these two media were used as samples. They were spiked with nivalenol, deoxynivalenol, zearalenone, diacetoxyscirpenol, T-2 toxin, verrucarol, verrucarin A, neosolaniol, sterigmatocystin, roridin A, ochratoxin A, aflatoxin B1, aflatoxin B2, aflatoxin G1 and aflatoxin G2, which can be produced by isolates from fungi-damaged buildings. Deepoxy-deoxynivalenol was used as internal standard. Samples were extracted with organic solvents and the different mycotoxins were separated by high-performance liquid chromatography (HPLC) using a C18 reversed-phase SunFire analytical column and a mobile phase of variable mixtures of ammonium acetate (10 mM) and sodium acetate (20 microM) in water (solvent A) and in methanol (solvent B). The samples were run on-line with a Micromass Quattro Micro triple quadrupole mass spectrometer in positive electrospray ionisation mode using multiple reaction monitoring (MRM). The detection limits of the procedure varied from 50 to 0.009 pg/microL for filter samples and from 75 to 0.04 pg/microL for fungal culture samples. As the method includes few and non-labourious sample treatment steps, it should allow for a high throughput of samples.


Subject(s)
Chromatography, High Pressure Liquid , Environmental Monitoring/methods , Mycotoxins/analysis , Sick Building Syndrome , Spectrometry, Mass, Electrospray Ionization/methods , Biomass , Cellulose/chemistry , Filtration , Penicillium/chemistry , Penicillium/metabolism
2.
Mycotoxin Res ; 22(2): 100-4, 2006 Jun.
Article in English | MEDLINE | ID: mdl-23605581

ABSTRACT

Rapid antibody-based mycotoxin screening techniques are designed to be used outside a laboratory environment, at the place of sampling. Results are expected immediately, so that commodities can be further processed without delay. Because they are used for mycotoxin analysis, very low levels (ppb and ppt range) should be detected. A further requirement is that the obtained results are accurate with a false negative rate of <5% at the level of interest.At first, plastic microtiter plates were used as solid phase materials for immobilizing antibodies (enzyme-linked immunosorbent assays). However, to increase speed and user-friendliness, plastics were replaced by microporous membranes. As an example a flow-through enzyme immunoassay for the detection of fumonisins in cornflakes with a cut-off value of 275 µg/kg is described. No false negative results were observed and the false positive rate was 18%. However, enzyme labels, used to enable visual evaluation of results, did not seem to be completely satisfactory in terms of stability and repeatability of the generated signal. Therefore microparticle labels such as colloidal gold particles are used more and more,e.g. in a lateral flow dipstick immunoassay. When applied to the detection of aflatoxin B1 in pig feed a cut-off value of 5 µg/kg could be reached with no false negative results and a false positive rate of only 10%. Sample pretreatment for screening techniques should be rapid and simple. Preferably a simple solvent extraction is used, followed by a filtration and dilution step. However, for strongly coloured or complex food matrices, this did not seem to work. The combination of clean-up and detection in one single test device is a new approach. When using this clean-up tandem assay column for the detection of ochratoxin A in roasted coffee, a cut-off value of 6 µg/kg was reached. No false positive results were obtained, however, the false negative rate was 8%.