Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 155
Filter
1.
Radiologie (Heidelb) ; 64(6): 453-455, 2024 Jun.
Article in German | MEDLINE | ID: mdl-38806751
2.
J Magn Reson Imaging ; 2024 May 11.
Article in English | MEDLINE | ID: mdl-38733369

ABSTRACT

BACKGROUND: Radiomics models trained on data from one center typically show a decline of performance when applied to data from external centers, hindering their introduction into large-scale clinical practice. Current expert recommendations suggest to use only reproducible radiomics features isolated by multiscanner test-retest experiments, which might help to overcome the problem of limited generalizability to external data. PURPOSE: To evaluate the influence of using only a subset of robust radiomics features, defined in a prior in vivo multi-MRI-scanner test-retest-study, on the performance and generalizability of radiomics models. STUDY TYPE: Retrospective. POPULATION: Patients with monoclonal plasma cell disorders. Training set (117 MRIs from center 1); internal test set (42 MRIs from center 1); external test set (143 MRIs from center 2-8). FIELD STRENGTH/SEQUENCE: 1.5T and 3.0T; T1-weighted turbo spin echo. ASSESSMENT: The task for the radiomics models was to predict plasma cell infiltration, determined by bone marrow biopsy, noninvasively from MRI. Radiomics machine learning models, including linear regressor, support vector regressor (SVR), and random forest regressor (RFR), were trained on data from center 1, using either all radiomics features, or using only reproducible radiomics features. Models were tested on an internal (center 1) and a multicentric external data set (center 2-8). STATISTICAL TESTS: Pearson correlation coefficient r and mean absolute error (MAE) between predicted and actual plasma cell infiltration. Fisher's z-transformation, Wilcoxon signed-rank test, Wilcoxon rank-sum test; significance level P < 0.05. RESULTS: When using only reproducible features compared with all features, the performance of the SVR on the external test set significantly improved (r = 0.43 vs. r = 0.18 and MAE = 22.6 vs. MAE = 28.2). For the RFR, the performance on the external test set deteriorated when using only reproducible instead of all radiomics features (r = 0.33 vs. r = 0.44, P = 0.29 and MAE = 21.9 vs. MAE = 20.5, P = 0.10). CONCLUSION: Using only reproducible radiomics features improves the external performance of some, but not all machine learning models, and did not automatically lead to an improvement of the external performance of the overall best radiomics model. TECHNICAL EFFICACY: Stage 2.

3.
Sci Rep ; 14(1): 7197, 2024 03 26.
Article in English | MEDLINE | ID: mdl-38531926

ABSTRACT

Cardiac Troponin I (cTnI) could be used to identify individuals at elevated risk of cardiac death in lung cancer (LC) screening settings. In a population-based, randomized LC screening trial in Germany ("LUSI" study) serum cTnI was measured by high-sensitivity assay in blood samples collected at baseline, and categorized into unquantifiable/low (< 6 ng/L), intermediate (≥ 6-15 ng/L), and elevated (≥ 16 ng/L). Cox proportional-hazard models were used to estimate risk of all-cause and cardiac mortality with cTnI levels. After exclusion criteria, 3653 participants were included for our analyses, of which 82.4% had low, 12.8% intermediate and 4.8% elevated cTnI, respectively. Over a median follow up of 11.87 years a total of 439 deaths occurred, including 67 caused by cardiac events. Within the first 5 years after cTnI measurement, intermediate or elevated cTnI levels showed approximately 1.7 (HR = 1.69 [95% CI 0.57-5.02) and 4.7-fold (HR = 4.66 [1.73-12.50]) increases in risk of cardiac death relative to individuals with unquantifiable/low cTnI, independently of age, sex, smoking and other risk factors. Within this time interval, a risk model based on age, sex, BMI, smoking history and cTnI showed a combined area under the ROC curve (AUC) of 73.6 (58.1-87.3), as compared to 70.4 (53.3-83.5) for a model without cTnI. Over the time interval of > 5-10 years after blood donation, the relative risk associations with cTnI and were weaker. cTnI showed no association with mortality from any other (non-cardiac) cause. Our findings show that cTnI may be of use for identifying individuals at elevated risk specifically of short-term cardiac mortality in the context of LC screening.


Subject(s)
Lung Neoplasms , Troponin I , Humans , Prognosis , Biomarkers , Early Detection of Cancer , ROC Curve , Predictive Value of Tests , Death
4.
Clin Transl Sci ; 16(12): 2483-2493, 2023 12.
Article in English | MEDLINE | ID: mdl-37920921

ABSTRACT

Expression of CYP3A5 protein is a basal and acquired resistance mechanism of pancreatic ductal adenocarcinoma cells conferring protection against the CYP3A and CYP2C8 substrate paclitaxel through metabolic degradation. Inhibition of CYP3A isozymes restores the cells sensitivity to paclitaxel. The combination of gemcitabine and nab-paclitaxel is an established regimen for the treatment of metastasized or locally advanced inoperable pancreatic cancer. Cobicistat is a CYP3A inhibitor developed for the pharmacoenhancement of protease inhibitors. The addition of cobicistat to gemcitabine and nab-paclitaxel may increase the antitumor effect. We will conduct a phase I dose escalation trial with a classical 3 + 3 design to investigate the safety, tolerability, and pharmacokinetics (PKs) of gemcitabine, nab-paclitaxel, and cobicistat. Although the doses of gemcitabine (1000 mg/m2 ) and cobicistat (150 mg) are fixed, three dose levels of nab-paclitaxel (75, 100, and 125 mg/m2 ) will be explored to account for a potential PK drug interaction. After the dose escalation phase, we will set the recommended dose for expansion (RDE) and treat up to nine patients in an expansion part of the trial. The trial is registered under the following identifiers EudraCT-Nr. 2019-001439-29, drks.de: DRKS00029409, and ct.gov: NCT05494866. Overcoming resistance to paclitaxel by CYP3A5 inhibition may lead to an increased efficacy of the gemcitabine and nab-paclitaxel regimen. Safety, efficacy, PK, and RDE data need to be acquired before investigating this combination in a large-scale clinical study.


Subject(s)
Carcinoma, Pancreatic Ductal , Cytostatic Agents , Pancreatic Neoplasms , Humans , Gemcitabine , Cytochrome P-450 CYP3A , Cytochrome P-450 CYP3A Inhibitors , Cytostatic Agents/therapeutic use , Deoxycytidine/adverse effects , Cobicistat , Antineoplastic Combined Chemotherapy Protocols/adverse effects , Paclitaxel/adverse effects , Pancreatic Neoplasms/drug therapy , Pancreatic Neoplasms/pathology , Carcinoma, Pancreatic Ductal/drug therapy , Carcinoma, Pancreatic Ductal/pathology , Clinical Trials, Phase I as Topic
5.
Nat Commun ; 14(1): 6761, 2023 10 24.
Article in English | MEDLINE | ID: mdl-37875494

ABSTRACT

Cancer of unknown primary has a dismal prognosis, especially following failure of platinum-based chemotherapy. 10-20% of patients have a high tumor mutational burden (TMB), which predicts response to immunotherapy in many cancer types. In this prospective, non-randomized, open-label, multicenter Phase II trial (EudraCT 2018-004562-33; NCT04131621), patients relapsed or refractory after platinum-based chemotherapy received nivolumab and ipilimumab following TMBhigh vs. TMBlow stratification. Progression-free survival (PFS) represented the primary endpoint; overall survival (OS), response rates, duration of clinical benefit and safety were the secondary endpoints. The trial was prematurely terminated in March 2021 before reaching the preplanned sample size (n = 194). Among 31 evaluable patients, 16% had a high TMB ( > 12 mutations/Mb). Overall response rate was 16% (95% CI 6-34%), with 7.7% (95% CI 1-25%) vs. 60% (95% CI 15-95%) in TMBlow and TMBhigh, respectively. Although the primary endpoint was not met, high TMB was associated with better median PFS (18.3 vs. 2.4 months) and OS (18.3 vs. 3.6 months). Severe immune-related adverse events were reported in 29% of cases. Assessing on-treatment dynamics of circulating tumor DNA using combined targeted hotspot mutation and shallow whole genome sequencing as part of a predefined exploratory analysis identified patients benefiting from immunotherapy irrespective of initial radiologic response.


Subject(s)
Lung Neoplasms , Neoplasms, Unknown Primary , Humans , Nivolumab/therapeutic use , Ipilimumab/therapeutic use , Neoplasms, Unknown Primary/drug therapy , Neoplasms, Unknown Primary/genetics , Prospective Studies , Lung Neoplasms/genetics , Antineoplastic Combined Chemotherapy Protocols/adverse effects
6.
Bone ; 175: 116857, 2023 10.
Article in English | MEDLINE | ID: mdl-37487861

ABSTRACT

PURPOSE: The presence of bone marrow focal lesions and osteolytic lesions in patients with multiple myeloma (MM) is of high prognostic significance for their individual outcome. It is not known yet why some focal lesions seen in MRI, reflecting localized bone marrow infiltration of myeloma cells, remain non-lytic, whereas others are associated with destruction of mineralized bone. In this study, we analyzed MRI characteristics of manually segmented focal lesions in MM patients to identify possible features that might discriminate lytic and non-lytic lesions. METHOD: The initial cohort included a total of 140 patients with different stages of MM who had undergone both whole-body MRI and whole-body low-dose CT within 30 days, and of which 29 satisfied the inclusion criteria for this study. Focal lesions in MRI and corresponding osteolytic areas in CT were segmented manually. Analysis of the lesions included volume, location and first order texture features analysis. RESULTS: There were significantly more lytic lesions in the axial skeleton than in the appendicular skeleton (p = 0.037). Out of 926 focal lesions in the axial skeleton seen on MRI, 544 (59.3 %) were osteolytic. Analysis of volume and first order texture features showed differences in texture and volume between focal lesions in MRI with and without local bone destruction in CT, but these findings were not statistically significant. CONCLUSIONS: Neither morphological imaging characteristics like size and location nor first order texture features could predict whether focal lesions seen in MRI would exhibit corresponding bone destruction in CT. Studies performing biopsies of such lesions are ongoing.


Subject(s)
Multiple Myeloma , Humans , Multiple Myeloma/diagnostic imaging , Multiple Myeloma/pathology , Bone Marrow/diagnostic imaging , Bone Marrow/pathology , Tomography, X-Ray Computed , Magnetic Resonance Imaging , Prognosis
7.
Skeletal Radiol ; 52(12): 2513-2518, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37300710

ABSTRACT

In multiple myeloma and its precursor stages, precise quantification of tumor load is of high importance for diagnosis, risk assessment, and therapy response evaluation. Both whole-body MRI, which allows to investigate the complete bone marrow of a patient, and bone marrow biopsy, which is commonly used to assess the histologic and genetic status, are relevant methods for tumor load assessment in multiple myeloma. We report on a series of striking mismatches between the plasma cell infiltration estimating the tumor load from unguided biopsies of the bone marrow at the posterior iliac crest and the tumor load assessment from whole-body MRI.


Subject(s)
Bone Marrow , Multiple Myeloma , Humans , Bone Marrow/diagnostic imaging , Bone Marrow/pathology , Multiple Myeloma/diagnostic imaging , Multiple Myeloma/pathology , Ilium/diagnostic imaging , Ilium/pathology , Tumor Burden , Magnetic Resonance Imaging/methods , Biopsy
8.
Invest Radiol ; 58(10): 754-765, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37222527

ABSTRACT

OBJECTIVES: In multiple myeloma and its precursor stages, plasma cell infiltration (PCI) and cytogenetic aberrations are important for staging, risk stratification, and response assessment. However, invasive bone marrow (BM) biopsies cannot be performed frequently and multifocally to assess the spatially heterogenous tumor tissue. Therefore, the goal of this study was to establish an automated framework to predict local BM biopsy results from magnetic resonance imaging (MRI). MATERIALS AND METHODS: This retrospective multicentric study used data from center 1 for algorithm training and internal testing, and data from center 2 to 8 for external testing. An nnU-Net was trained for automated segmentation of pelvic BM from T1-weighted whole-body MRI. Radiomics features were extracted from these segmentations, and random forest models were trained to predict PCI and the presence or absence of cytogenetic aberrations. Pearson correlation coefficient and the area under the receiver operating characteristic were used to evaluate the prediction performance for PCI and cytogenetic aberrations, respectively. RESULTS: A total of 672 MRIs from 512 patients (median age, 61 years; interquartile range, 53-67 years; 307 men) from 8 centers and 370 corresponding BM biopsies were included. The predicted PCI from the best model was significantly correlated ( P ≤ 0.01) to the actual PCI from biopsy in all internal and external test sets (internal test set: r = 0.71 [0.51, 0.83]; center 2, high-quality test set: r = 0.45 [0.12, 0.69]; center 2, other test set: r = 0.30 [0.07, 0.49]; multicenter test set: r = 0.57 [0.30, 0.76]). The areas under the receiver operating characteristic of the prediction models for the different cytogenetic aberrations ranged from 0.57 to 0.76 for the internal test set, but no model generalized well to all 3 external test sets. CONCLUSIONS: The automated image analysis framework established in this study allows for noninvasive prediction of a surrogate parameter for PCI, which is significantly correlated to the actual PCI from BM biopsy.


Subject(s)
Deep Learning , Multiple Myeloma , Male , Humans , Middle Aged , Multiple Myeloma/diagnostic imaging , Multiple Myeloma/genetics , Bone Marrow/diagnostic imaging , Retrospective Studies , Magnetic Resonance Imaging/methods , Biopsy , Chromosome Aberrations
9.
Radiologie (Heidelb) ; 63(5): 346-353, 2023 May.
Article in German | MEDLINE | ID: mdl-37186291

ABSTRACT

PROBLEM: If no obvious primary tumour is detectable in metastatic tumours (cancer of unknown primary, CUP), it should nevertheless be identified if possible, as specific therapy achieves better results than empirical, palliative treatment of CUP. METHODOLOGY: The new guideline of the European Society of Medical Oncology (ESMO) defines algorithms for the evaluation of CUP, in which radiological and nuclear imaging procedures play a central role. Important clues to a possible primary tumour are the size and morphology of foci and the presence of a dominant lesion, as well as the pattern of hematogeneous metastatic spread in affected organs, and the anatomical distribution of affected lymph nodes. CONCLUSION: In patients with metastases, imaging plays an important role in identifying a possible primary tumour, but the diagnosis must be made with knowledge of the clinical and immunohistochemical results. In difficult cases, there should be interdisciplinary consultation between reference oncology, radiology, and pathology on the presence of CUP.


Subject(s)
Diagnostic Imaging , Radiology , Humans , Diagnostic Imaging/methods , Radiography
10.
Br J Radiol ; 96(1145): 20220745, 2023 Apr 01.
Article in English | MEDLINE | ID: mdl-37001052

ABSTRACT

OBJECTIVE: To investigate the reproducibility of size measurements of focal bone marrow lesions (FL) in MRI in patients with monoclonal plasma cell disorders under variation of patient positioning and observer. METHODS: A data set from a prospective test-retest study was used, in which 37 patients with a total of 140 FL had undergone 2 MRI scans with identical parameters after patient repositioning. Two readers measured long and short axis diameter on the initial scan in T1 weighted, T2 weighted short tau inversion recovery and diffusion-weighted imaging sequences. The first reader additionally measured FL on the retest-scan. The Bland-Altman method was used to assess limits of agreement (LoA), and the frequencies of absolute size changes were calculated. RESULTS: In the simple test-retest experiment with one identical reader, a deviation of ≥1 mm / ≥2 mm / ≥3 mm for the long axis diameter in T1 weighted images was observed in 66% / 25% / 8% of cases. When comparing measurements of one reader on the first scan to the measurement of the other reader on the retest scan, a change of ≥1 mm / ≥3 mm / ≥5 mm for the long axis diameter in T1 weighted images was observed in 78% / 21% / 5% of cases. CONCLUSION: Small deviations in FL size are common and probably due to variation in patient positioning or inter-rater variability alone, without any actual biological change of the FL. Knowledge of the uncertainty associated with size measurements of FLs is critical for radiologists and oncologists when interpreting changes in FL size in clinical practice and in clinical trials. ADVANCES IN KNOWLEDGE: According to the MY-RADs criteria, size measurements of focal lesions in MRI are now of relevance for response assessment in patients with monoclonal plasma cell disorders.Size changes of 1 or 2 mm are frequently observed due to uncertainty of the measurement only, while the actual focal lesion has not undergone any biological change.Size changes of at least 6 mm or more in T1 weighted or T2 weighted short tau inversion recovery sequences occur in only 5% or less of cases when the focal lesion has not undergone any biological change.


Subject(s)
Bone Diseases , Multiple Myeloma , Humans , Multiple Myeloma/diagnostic imaging , Bone Marrow/diagnostic imaging , Prospective Studies , Reproducibility of Results , Retrospective Studies , Magnetic Resonance Imaging/methods
11.
Invest Radiol ; 58(4): 273-282, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36256790

ABSTRACT

OBJECTIVES: Diffusion-weighted magnetic resonance imaging (MRI) is increasingly important in patients with multiple myeloma (MM). The objective of this study was to train and test an algorithm for automatic pelvic bone marrow analysis from whole-body apparent diffusion coefficient (ADC) maps in patients with MM, which automatically segments pelvic bones and subsequently extracts objective, representative ADC measurements from each bone. MATERIALS AND METHODS: In this retrospective multicentric study, 180 MRIs from 54 patients were annotated (semi)manually and used to train an nnU-Net for automatic, individual segmentation of the right hip bone, the left hip bone, and the sacral bone. The quality of the automatic segmentation was evaluated on 15 manually segmented whole-body MRIs from 3 centers using the dice score. In 3 independent test sets from 3 centers, which comprised a total of 312 whole-body MRIs, agreement between automatically extracted mean ADC values from the nnU-Net segmentation and manual ADC measurements from 2 independent radiologists was evaluated. Bland-Altman plots were constructed, and absolute bias, relative bias to mean, limits of agreement, and coefficients of variation were calculated. In 56 patients with newly diagnosed MM who had undergone bone marrow biopsy, ADC measurements were correlated with biopsy results using Spearman correlation. RESULTS: The ADC-nnU-Net achieved automatic segmentations with mean dice scores of 0.92, 0.93, and 0.85 for the right pelvis, the left pelvis, and the sacral bone, whereas the interrater experiment gave mean dice scores of 0.86, 0.86, and 0.77, respectively. The agreement between radiologists' manual ADC measurements and automatic ADC measurements was as follows: the bias between the first reader and the automatic approach was 49 × 10 -6 mm 2 /s, 7 × 10 -6 mm 2 /s, and -58 × 10 -6 mm 2 /s, and the bias between the second reader and the automatic approach was 12 × 10 -6 mm 2 /s, 2 × 10 -6 mm 2 /s, and -66 × 10 -6 mm 2 /s for the right pelvis, the left pelvis, and the sacral bone, respectively. The bias between reader 1 and reader 2 was 40 × 10 -6 mm 2 /s, 8 × 10 -6 mm 2 /s, and 7 × 10 -6 mm 2 /s, and the mean absolute difference between manual readers was 84 × 10 -6 mm 2 /s, 65 × 10 -6 mm 2 /s, and 75 × 10 -6 mm 2 /s. Automatically extracted ADC values significantly correlated with bone marrow plasma cell infiltration ( R = 0.36, P = 0.007). CONCLUSIONS: In this study, a nnU-Net was trained that can automatically segment pelvic bone marrow from whole-body ADC maps in multicentric data sets with a quality comparable to manual segmentations. This approach allows automatic, objective bone marrow ADC measurements, which agree well with manual ADC measurements and can help to overcome interrater variability or nonrepresentative measurements. Automatically extracted ADC values significantly correlate with bone marrow plasma cell infiltration and might be of value for automatic staging, risk stratification, or therapy response assessment.


Subject(s)
Deep Learning , Multiple Myeloma , Humans , Magnetic Resonance Imaging/methods , Multiple Myeloma/diagnostic imaging , Multiple Myeloma/pathology , Bone Marrow/diagnostic imaging , Retrospective Studies , Whole Body Imaging/methods , Diffusion Magnetic Resonance Imaging/methods
12.
Invest Radiol ; 58(4): 253-264, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36165988

ABSTRACT

OBJECTIVES: Despite the extensive number of publications in the field of radiomics, radiomics algorithms barely enter large-scale clinical application. Supposedly, the low external generalizability of radiomics models is one of the main reasons, which hinders the translation from research to clinical application. The objectives of this study were to investigate reproducibility of radiomics features (RFs) in vivo under variation of patient positioning, magnetic resonance imaging (MRI) sequence, and MRI scanners, and to identify a subgroup of RFs that shows acceptable reproducibility across all different acquisition scenarios. MATERIALS AND METHODS: Between November 30, 2020 and February 16, 2021, 55 patients with monoclonal plasma cell disorders were included in this prospective, bi-institutional, single-vendor study. Participants underwent one reference scan at a 1.5 T MRI scanner and several retest scans: once after simple repositioning, once with a second MRI protocol, once at another 1.5 T scanner, and once at a 3 T scanner. Radiomics feature from the bone marrow of the left hip bone were extracted, both from original scans and after different image normalizations. Intraclass correlation coefficient (ICC) was used to assess RF repeatability and reproducibility. RESULTS: Fifty-five participants (mean age, 59 ± 7 years; 36 men) were enrolled. For T1-weighted images after muscle normalization, in the simple test-retest experiment, 110 (37%) of 295 RFs showed an ICC ≥0.8: 54 (61%) of 89 first-order features (FOFs), 35 (95%) of 37 volume and shape features, and 21 (12%) of 169 texture features (TFs). When the retest was performed with different technical settings, even after muscle normalization, the number of FOF/TF with an ICC ≥0.8 declined to 58/13 for the second protocol, 29/7 for the second 1.5 T scanner, and 49/7 for the 3 T scanner, respectively. Twenty-five (28%) of the 89 FOFs and 6 (4%) of the 169 TFs from muscle-normalized T1-weighted images showed an ICC ≥0.8 throughout all repeatability and reproducibility experiments. CONCLUSIONS: In vivo, only few RFs are reproducible with different MRI sequences or different MRI scanners, even after application of a simple image normalization. Radiomics features selected by a repeatability experiment only are not necessarily suited to build radiomics models for multicenter clinical application. This study isolated a subset of RFs, which are robust to variations in MRI acquisition observed in scanners from 1 vendor, and therefore are candidates to build reproducible radiomics models for monoclonal plasma cell disorders for multicentric applications, at least when centers are equipped with scanners from this vendor.


Subject(s)
Image Processing, Computer-Assisted , Plasma Cells , Male , Humans , Middle Aged , Aged , Prospective Studies , Reproducibility of Results , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods
13.
Transl Lung Cancer Res ; 12(12): 2460-2475, 2023 Dec 26.
Article in English | MEDLINE | ID: mdl-38205209

ABSTRACT

Background: Lung cancer (LC) screening can be optimized using individuals' estimated risks of having a detectable lung tumor, as well as of mortality risk by competing causes, to guide decisions on screening eligibility, ideal screening intervals and stopping ages. Besides age, sex and smoking history, blood-based biomarkers may be used to improve the assessment of LC risk and risk of mortality by competing causes. Methods: In the German randomized Lung Screening Intervention Trial (LUSI), we measured growth/differentiation factor-15 (GDF-15), interleukin-6 (IL-6), C-reactive protein (CRP) and N-terminal pro-brain natriuretic protein (NT-proBNP), in blood serum samples collected at start of the trial. Participants in the computed tomography (CT)-screening arm also had a pulmonary function test. Regression models were used to examine these markers as predictors for impaired lung function, LC risk and mortality due to LC or other causes, independently of age, sex and smoking history. Results: Our models showed increases in LC risk among participants with elevated serum levels of GDF-15 [odds ratio (OR)Q4-Q1 =2.47, 95% confidence interval (CI): 1.49-4.26], IL-6 [ORQ4-Q1 =2.36 (1.43-4.00)] and CRP [ORQ4-Q1 =1.81 (1.08-2.75)]. Likewise, proportional hazards models showed increased risks for LC-related mortality, hazard ratio (HR)Q4-Q1 of 4.63 (95% CI: 2.13-10.07) for GDF-15, 3.56 (1.72-7.37) for IL-6 and 2.34 (1.24-4.39) for CRP. All four markers were associated with increased risk of mortality by causes other than LC, with strongest associations for GDF-15 [HRQ4-Q1 =3.04 (2.09-4.43)] and IL-6 [HRQ4-Q1 =2.98 (2.08-4.28)]. Significant associations were also observed between IL-6, CRP, GDF-15 and impaired pulmonary function [chronic obstructive pulmonary disease (COPD), preserved ratio impaired spirometry (PRISm)]. Multi-marker models identified GDF-15 and IL-6 as joint risk predictors for risk of LC diagnosis, without further discrimination by CRP or NT-proBNP. A model based on age, sex, smoking-related variables, GFD-15 and IL-6 provided moderately strong discrimination for prediction of LC diagnoses within 9 years after blood sampling [area under the curve (AUC) =74.3% (57.3-90.2%)], compared to 67.0% (49.3-84.8%) for a model without biomarkers. For mortality by competing causes, a model including biomarkers resulted in an AUC of 76.2% (66.6-85.3%)], compared to 70.0% (60.9-77.9%) a model including age, sex and smoking variables. Conclusions: Serum GDF-15 and IL-6 may be useful indicators for estimating risks for LC and competing mortality among long-term smokers participating in LC screening, to optimize LC screening strategies.

14.
Transl Lung Cancer Res ; 11(9): 1896-1911, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36248328

ABSTRACT

Background: Lung cancer screening may provide a favorable opportunity for a spirometry examination, to diagnose participants with undiagnosed lung function impairments, or to improve targeting of computed tomography (CT) screening intensity in view of expected net benefit. Methods: Spirometry was performed in the CT screening arm (n=2,029) of the German Lung Cancer Screening Intervention Study (LUSI)-a trial examining the effects of annual CT screening on lung cancer mortality, in 50-69-year-old long-term smokers. Participants were classified as having chronic obstructive pulmonary disease (COPD) [forced expiration in one second (FEV1)/forced vital lung capacity (FVC) <0.7], preserved ratio impaired spirometry (PRISm; FEV1/FVC ≥0.7 and FEV1% predicted <80%), or normal spirometry. Descriptive statistics were used to examine associations of COPD or PRISm with respiratory symptoms, and self-reported medical diagnoses of respiratory and other morbidities. Logistic regression and proportional hazards regression were used to examine associations of COPD and PRISm, as well as their self-reported medical diagnoses, with risks of lung cancer and all-cause mortality. Results: A total of 1,987 screening arm participants (98%) provided interpretable spirometry measurements; of these, 34.3% had spirometric patterns consistent with either COPD (18.6%) or PRISm (15.7%). Two thirds of participants with COPD or PRISm were asymptomatic, and only 23% reported a previous medical diagnosis concordant with COPD. Participants reporting a diagnosis tended to be more often current and heavier smokers, and more often had respiratory symptoms, cardiovascular comorbidities, or more severe lung function impairments. Independently of smoking history, moderate-to-severe (GOLD 2-4) COPD (OR =2.14; 95% CI: 1.54-2.98), and PRISm (OR =2.68; 95% CI: 1.61-4.40), were associated with increased lung cancer risk. Lung cancer patients with PRISm less frequently had adenocarcinomas, and more often squamous cell or small cell tumors, compared to those with normal spirometry (n=45), and both PRISm and COPD were associated with more advanced lung cancer tumor stage for screen-detected cancers. PRISm and COPD, depending on GOLD stage, were also associated with about 2- to 4-fold increases in risk of overall mortality, which to 87 percent had causes other than lung cancer. Conclusions: About one third of smokers eligible for lung cancer screening in Germany have COPD or PRISm. As these conditions were associated with detection of lung cancer, spirometry may help identify populations at high risk for death of lung cancer or other causes, and who might particularly benefit from CT screening.

15.
Radiologie (Heidelb) ; 62(6): 465-466, 2022 06.
Article in German | MEDLINE | ID: mdl-35925063
17.
Invest Radiol ; 57(11): 752-763, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-35640004

ABSTRACT

OBJECTIVES: Disseminated bone marrow (BM) involvement is frequent in multiple myeloma (MM). Whole-body magnetic resonance imaging (wb-MRI) enables to evaluate the whole BM. Reading of such whole-body scans is time-consuming, and yet radiologists can transfer only a small fraction of the information of the imaging data set to the report. This limits the influence that imaging can have on clinical decision-making and in research toward precision oncology. The objective of this feasibility study was to implement a concept for automatic, comprehensive characterization of the BM from wb-MRI, by automatic BM segmentation and subsequent radiomics analysis of 30 different BM spaces (BMS). MATERIALS AND METHODS: This retrospective multicentric pilot study used a total of 106 wb-MRI from 102 patients with (smoldering) MM from 8 centers. Fifty wb-MRI from center 1 were used for training of segmentation algorithms (nnU-Nets) and radiomics algorithms. Fifty-six wb-MRI from 8 centers, acquired with a variety of different MRI scanners and protocols, were used for independent testing. Manual segmentations of 2700 BMS from 90 wb-MRI were performed for training and testing of the segmentation algorithms. For each BMS, 296 radiomics features were calculated individually. Dice score was used to assess similarity between automatic segmentations and manual reference segmentations. RESULTS: The "multilabel nnU-Net" segmentation algorithm, which performs segmentation of 30 BMS and labels them individually, reached mean dice scores of 0.88 ± 0.06/0.87 ± 0.06/0.83 ± 0.11 in independent test sets from center 1/center 2/center 3-8 (interrater variability between radiologists, 0.88 ± 0.01). The subset from the multicenter, multivendor test set (center 3-8) that was of high imaging quality was segmented with high precision (mean dice score, 0.87), comparable to the internal test data from center 1. The radiomic BM phenotype consisting of 8880 descriptive parameters per patient, which result from calculation of 296 radiomics features for each of the 30 BMS, was calculated for all patients. Exemplary cases demonstrated connections between typical BM patterns in MM and radiomic signatures of the respective BMS. In plausibility tests, predicted size and weight based on radiomics models of the radiomic BM phenotype significantly correlated with patients' actual size and weight ( P = 0.002 and P = 0.003, respectively). CONCLUSIONS: This pilot study demonstrates the feasibility of automatic, objective, comprehensive BM characterization from wb-MRI in multicentric data sets. This concept allows the extraction of high-dimensional phenotypes to capture the complexity of disseminated BM disorders from imaging. Further studies need to assess the clinical potential of this method for automatic staging, therapy response assessment, or prediction of biopsy results.


Subject(s)
Deep Learning , Neoplasms , Bone Marrow/diagnostic imaging , Feasibility Studies , Humans , Magnetic Resonance Imaging/methods , Pilot Projects , Precision Medicine , Retrospective Studies , Whole Body Imaging
18.
Br J Haematol ; 199(1): 65-75, 2022 10.
Article in English | MEDLINE | ID: mdl-35608264

ABSTRACT

The definition of multiple myeloma (MM) was updated in 2014, with the intent to enable earlier treatment and thereby avoid appearance of end-organ damage at progression from smouldering multiple myeloma (SMM) to MM. The purpose of this study was to investigate to which extent the development of end-organ damage at progression to MM was reduced under the updated guidelines. In this prospective observational cohort study (ClinicalTrials.gov Identifier: NCT01374412), between 2014 and 2020, 96 SMM patients prospectively underwent whole-body magnetic resonance imaging (wb-MRI) and serological follow-up at baseline and every 6 months thereafter. A total of 22 patients progressed into MM during follow-up, of which seven (32%) showed SLiM-criteria only but no end-organ damage. Four (57%) of the seven patients who progressed by SLiM-criteria only progressed with >1 focal lesion (FL) or a growing FL, and three (43%) due to serum free light-chain-ratio ≥100. Fifteen (68%) out of 22 patients who progressed still suffered from end-organ damage at progression. The updated disease definition reduced the proportion of SMM patients suffering from end-organ damage at progression to MM by one third. wb-MRI is an important tool for detection of SMM patients who progress to MM without end-organ damage.


Subject(s)
Multiple Myeloma , Smoldering Multiple Myeloma , Disease Progression , Follow-Up Studies , Humans , Magnetic Resonance Imaging , Multiple Myeloma/pathology , Prospective Studies , Smoldering Multiple Myeloma/diagnostic imaging , Whole Body Imaging
19.
Invest Radiol ; 57(4): 272-281, 2022 04 01.
Article in English | MEDLINE | ID: mdl-34839306

ABSTRACT

BACKGROUND/OBJECTIVES: Apparent diffusion coefficient (ADC) and signal intensity (SI) measurements play an increasing role in magnetic resonance imaging (MRI) of monoclonal plasma cell disorders. The purpose of this study was to assess interrater variability, repeatability, and reproducibility of ADC and SI measurements from bone marrow (BM) under variation of MRI protocols and scanners. PATIENTS AND METHODS: Fifty-five patients with suspected or confirmed monoclonal plasma cell disorder were prospectively included in this institutional review board-approved study and underwent several measurements after the standard clinical whole-body MR scan, including repeated scan after repositioning, scan with a second MRI protocol, scan at a second 1.5 T scanner with a harmonized MRI protocol, and scan at a 3 T scanner. For T1-weighted, T2-weighted STIR, B800 images, and ADC maps, regions of interest were placed in the BM of the iliac crest and sacral bone, and in muscle tissue for image normalization. Bland-Altman plots were constructed, and absolute bias, relative bias to mean, limits of agreement, and coefficients of variation were calculated. RESULTS: Interrater variability and repeatability experiments showed a maximal relative bias of -0.077 and a maximal coefficient of variation of 16.2% for all sequences. Although the deviations at the second 1.5 T scanner with harmonized MRI protocol to the first 1.5 T scanner showed a maximal relative bias of 0.124 for all sequences, the variation of the MRI protocol and scan at the 3 T scanner led to large relative biases of up to -0.357 and -0.526, respectively. When comparing the 3 T scanner to the 1.5 T scanner, normalization to muscle reduced the bias of T1-weighted and T2-weighted sequences, but not of ADC maps. CONCLUSIONS: The MRI scanners with identical field strength and harmonized MRI protocols can provide relatively stable quantitative measurements of BM ADC and SI. Deviations in MRI field strength and MRI protocol should be avoided when applying ADC cutoff values, which were established at other scanners or when performing multicentric imaging trials.


Subject(s)
Bone Marrow , Plasma Cells , Bone Marrow/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Humans , Magnetic Resonance Imaging , Prospective Studies , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...