Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Microbiol ; 35(4): 1027-9, 1997 Apr.
Article in English | MEDLINE | ID: mdl-9157125

ABSTRACT

The susceptibility of Pseudomonas aeruginosa to imipenem has been shown to vary according to zinc concentration in the media. MICs of imipenem for 68 unique clinical isolates of P. aeruginosa were determined in media supplemented with zinc at concentrations between 0.5 and 6.0 micrograms/ml. In agar containing up to 3 micrograms of zinc/ml, 75 to 82% of the strains were susceptible to imipenem at an MIC of < or = 4 micrograms/ml. In agar supplemented to contain 6 micrograms of zinc/ml, however, only 40% of the strains were susceptible to imipenem. Manufacturers should ensure that the concentration of zinc in commercial media is below 3 micrograms/ml to avoid false classification of isolates as resistant to imipenem.


Subject(s)
Imipenem/pharmacology , Microbial Sensitivity Tests , Pseudomonas aeruginosa/drug effects , Thienamycins/pharmacology , Agar , Zinc
2.
J Clin Microbiol ; 32(10): 2584-7, 1994 Oct.
Article in English | MEDLINE | ID: mdl-7814505

ABSTRACT

We performed a 15-month study using 11 clinical strains and 1 control strain (ATCC 27853) of Pseudomonas aeruginosa to determine whether changes in the manufacturing process of Sensititre predried panels result in a reliable test of susceptibility to imipenem. MIC and breakpoint susceptibility results remained stable during the manufacturer's recommended shelf life of 18 months and compared well with standard agar disk diffusion and broth macrodilution results. Imipenem concentrations measured by high-pressure liquid chromatography were acceptable through 15 months but declined in the breakpoint panels by approximately 50% at 18 months. Between 9 months and panel expiration, 13 of 141 (9%) of the MIC panel packages had moisture entry, as indicated by pink desiccants, with a resultant loss of imipenem activity of 32 to 100%. It appears that the new manufacturing process produces MIC panels that are reliable for imipenem susceptibility testing until the labeled expiration date, provided that packages containing pink desiccants are not used.


Subject(s)
Imipenem/chemistry , Imipenem/pharmacology , Chromatography, High Pressure Liquid , Drug Stability , Imipenem/analysis , Microbial Sensitivity Tests
SELECTION OF CITATIONS
SEARCH DETAIL
...