Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pediatr Diabetes ; 17(1): 28-35, 2016 Feb.
Article in English | MEDLINE | ID: mdl-25348683

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the safety and performance of the artificial pancreas (AP) in adolescents with type 1 diabetes (T1D) following insulin omission for food. RESEARCH DESIGN AND METHODS: In a randomized, cross-over trial, adolescents with T1D aged 13-18 yr were enrolled in a randomized, cross-over trial. On separate days, received either usual care (UC) through their home insulin pump or used an AP system (Diabetes Assistant platform, continuous glucose monitor, and insulin pump). Approximately 1 h after admission, participants in both groups received an unannounced snack of 30 g carbohydrate, and 4 h later they received an 80 g lunch, for which both groups only received 75% of the calculated insulin dose to cover carbohydrates. On the UC day (but not the AP day), they received their full high blood glucose (BG) correction factor at lunch. Each admission lasted approximately 8 h. RESULTS: A total of 16 participants completed the trial. On the AP day (compared to UC), mean BG was lower (197 ± 10 vs. 235 ± 14 mg/dL) and time in range 70-180 mg/dL was higher (43% ± 7 vs. 19% ± 7) (both p < 0.05) overall; these results held in the time following the snack and meal (also p < 0.05). During the trial, there were no differences between groups in the rate of hypoglycemia <70 mg/dL. CONCLUSIONS: The AP provided improvements in short-term glycemic control without increases in hypoglycemia following missed insulin for food in adolescents. Thus, the AP partly compensates for missed insulin boluses for food, a common occurrence in adolescent diabetes care. Further testing is needed in longer-term settings.


Subject(s)
Blood Glucose/metabolism , Diabetes Mellitus, Type 1/therapy , Meals , Pancreas, Artificial/statistics & numerical data , Adolescent , Cross-Over Studies , Diabetes Mellitus, Type 1/blood , Female , Humans , Male , Postprandial Period , Snacks , Treatment Outcome
2.
Diabetes ; 61(9): 2230-7, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22688340

ABSTRACT

Integrated closed-loop control (CLC), combining continuous glucose monitoring (CGM) with insulin pump (continuous subcutaneous insulin infusion [CSII]), known as artificial pancreas, can help optimize glycemic control in diabetes. We present a fundamental modular concept for CLC design, illustrated by clinical studies involving 11 adolescents and 27 adults at the Universities of Virginia, Padova, and Montpellier. We tested two modular CLC constructs: standard control to range (sCTR), designed to augment pump plus CGM by preventing extreme glucose excursions; and enhanced control to range (eCTR), designed to truly optimize control within near normoglycemia of 3.9-10 mmol/L. The CLC system was fully integrated using automated data transfer CGM→algorithm→CSII. All studies used randomized crossover design comparing CSII versus CLC during identical 22-h hospitalizations including meals, overnight rest, and 30-min exercise. sCTR increased significantly the time in near normoglycemia from 61 to 74%, simultaneously reducing hypoglycemia 2.7-fold. eCTR improved mean blood glucose from 7.73 to 6.68 mmol/L without increasing hypoglycemia, achieved 97% in near normoglycemia and 77% in tight glycemic control, and reduced variability overnight. In conclusion, sCTR and eCTR represent sequential steps toward automated CLC, preventing extremes (sCTR) and further optimizing control (eCTR). This approach inspires compelling new concepts: modular assembly, sequential deployment, testing, and clinical acceptance of custom-built CLC systems tailored to individual patient needs.


Subject(s)
Blood Glucose/metabolism , Diabetes Mellitus, Type 1/drug therapy , Insulin Infusion Systems , Pancreas, Artificial , Adolescent , Adult , Algorithms , Automation , Computer Simulation , Cross-Over Studies , Diabetes Mellitus, Type 1/blood , Humans , Hypoglycemic Agents/therapeutic use , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...