Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anesthesiology ; 92(3): 646-56, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10719942

ABSTRACT

BACKGROUND: Risks associated with transfusion of allogeneic blood have prompted development of methods to avoid or reduce blood transfusions. New oxygen-carrying compounds such as diaspirin cross-linked hemoglobin (DCLHb) could enable more patients to avoid allogeneic blood transfusion. METHODS: The efficacy, safety, hemodynamic effects, and plasma persistence of DCLHb were investigated in a randomized, active-control, single-blind, multicenter study in post-cardiac bypass surgery patients. Of 1,956 screened patients, 209 were determined to require a blood transfusion and met the inclusion criteria during the 24-h post-cardiac bypass period. These patients were randomized to receive up to three 250-ml infusions of DCLHb (n = 104) or three units of packed erythrocytes (pRBCs; n = 105). Further transfusions of pRBCs or whole blood were permitted, if indicated. Primary efficacy end points were the avoidance of blood transfusion through hospital discharge or 7 days postsurgery, whichever came first, and a reduction in the number of units of pRBCs transfused during this same time period. Various laboratory, physiologic, and hemodynamic parameters were monitored to define the safety and pharmacologic effect of DCLHb in this patient population. RESULTS: During the period from the end of cardiopulmonary bypass surgery through postoperative day 7 or hospital discharge, 20 of 104 (19%) DCLHb recipients did not receive a transfusion of pRBCs compared with 100% of control patients (P < 0.05). The overall number of pRBCs administered during the 7-day postoperative period was not significantly different. Mortality was similar between the DCLHb (6 of 104 patients) and the control (8 of 105 patients) groups. Hypertension, jaundice/hyperbilirubinemia, increased serum glutamic oxalo-acetic transaminase, abnormal urine, and hematuria were reported more frequently in the DCLHb group, and there was one case of renal failure in each group. The hemodynamic effects of DCLHb included a consistent and slightly greater increase in systemic and pulmonary vascular resistance with associated increases in systemic and pulmonary arterial pressures compared with pRBC. Cardiac output values decreased more in the DCLHb group patients after the first administration than the control group patients. At 24 h postinfusion, the plasma hemoglobin level was less than one half the maximal level for any amount of DCLHb infused. CONCLUSIONS: Administration of DCLHb allowed a significant number (19%) of cardiac surgery patients to avoid exposure to erythrocytes postoperatively.


Subject(s)
Aspirin/analogs & derivatives , Blood Substitutes/therapeutic use , Blood Transfusion , Cardiac Surgical Procedures , Hemoglobins/therapeutic use , Aged , Aspirin/adverse effects , Aspirin/pharmacokinetics , Aspirin/therapeutic use , Blood Substitutes/pharmacokinetics , Female , Hematocrit , Hemodynamics/drug effects , Hemodynamics/physiology , Hemoglobins/adverse effects , Hemoglobins/pharmacokinetics , Humans , Isotonic Solutions , Male , Middle Aged , Myocardium/enzymology , Reticulocyte Count , Ringer's Solution , Single-Blind Method
2.
Ann Thorac Surg ; 55(5): 1141-6, 1993 May.
Article in English | MEDLINE | ID: mdl-8494423

ABSTRACT

Eighteen patients suffering from acute left heart failure were selected as candidates for Hemopump support. In 6 patients, peripheral atheromatosis prevented insertion of the device. Of the remaining 12 patients, 9 had postcardiotomy shock, 2 had acute rejection after orthotopic heart transplantation, and 1 had acute myocardial infarction complicated by a large postinfarction ventricular septal defect. During Hemopump support, hemodynamics recovered in all patients. Major complications were related to mechanical pump failure, such as fracture of the drive cable and expulsion of the cannula out of the ventricle, or to hemolysis of variable degree. Seven patients (58%) survived and were discharged from the hospital: the 2 patients bridged to heart transplantation and 5 of the 9 postcardiotomy patients, including 1 who could not be weaned but later underwent successful transplantation. The patient with the postinfarction ventricular septal defect died after removal of the device because of hemolysis. These results indicate that the Hemopump is a relatively noninvasive and efficacious left ventricular system of moderate power.


Subject(s)
Cardiac Output, Low/therapy , Heart-Assist Devices , Adult , Aged , Blood Pressure/physiology , Cardiac Output/physiology , Cardiac Output, Low/etiology , Cardiac Output, Low/physiopathology , Central Venous Pressure/physiology , Equipment Design , Equipment Failure , Female , Graft Rejection/complications , Heart Transplantation/adverse effects , Heart-Assist Devices/adverse effects , Hemolysis , Humans , Male , Middle Aged , Myocardial Infarction/complications , Shock, Cardiogenic/complications , Survival Rate , Treatment Outcome , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...