Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Imaging ; 56: 45-51, 2019 02.
Article in English | MEDLINE | ID: mdl-30344057

ABSTRACT

The tools for developing systems for NMR improve each year. Some firmware based designs based on Field Programmable Gate Arrays (FPGAs) have been developed to implement both the core and peripheral apparatus for NMR Relaxometers and NMR Cryoporometers. Hand held in size they are particularly suitable for desktop, mobile and field use. Software tools now enable the writing of firmware that enable the rapid design of digital and digitised R.F. data and control systems. This firmware can then be loaded into and run on hardware that often is only the size of a credit-card. These devices can include a single-chip Linux computer with an FPGA capable of processing digital RF on the same chip. These can generate RF signals digitally, process RF signals for up- and down-conversion, and can provide an on chip NMR pulse sequencer. An extremely well tested NMR digital transmitter has been upgraded to use the latest surface-mount Bipolar and Field Effect Transistors. The circuitry is now the size of a book of matches, and interfaces to credit-card sized FPGA modules for RF generation, phase shifting and drive signals. This NMR transmitter design uses digital logic principles rather than conventional tuned R.F. techniques Offering both active-damping and active-quench, a very square R.F. Pulse with fast turn off is achieved, with Mark 1 giving 2.6 µs π/2 and 4.8 µs π pulses into a 5 mm diameter NMR sample (2.7 mT B1) at 20 MHz for Protons. T1ρ pulses are stable and consistent.


Subject(s)
Magnetic Resonance Spectroscopy/instrumentation , Magnetic Resonance Spectroscopy/methods , Signal Processing, Computer-Assisted/instrumentation , Equipment Design
2.
Philos Trans A Math Phys Eng Sci ; 377(2137)2018 Dec 10.
Article in English | MEDLINE | ID: mdl-30530546

ABSTRACT

We report on the first steps in the development of a small-size muon telescope based on glass resistive plate chambers with small active area (16 × 16 cm2). The long-term goal of this project is to focus on applications of muography where the telescope may have to be operated underground and/or inside small rooms, and in challenging logistic situations. Driving principles in our design are therefore compact size, light weight, gas tightness and robustness. The first data-taking experiences have been encouraging, and we elaborate on the lessons learnt and future directions for development.This article is part of the Theo Murphy meeting issue 'Cosmic-ray muography'.

SELECTION OF CITATIONS
SEARCH DETAIL
...