Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Lett ; 41(22): 5170-5173, 2016 Nov 15.
Article in English | MEDLINE | ID: mdl-27842085

ABSTRACT

We present a table-top coherent diffractive imaging (CDI) experiment based on high-order harmonics generated at 18 nm by a high average power femtosecond fiber laser system. The high photon flux, narrow spectral bandwidth, and high degree of spatial coherence allow for ultrahigh subwavelength resolution imaging at a high numerical aperture. Our experiments demonstrate a half-pitch resolution of 15 nm, close to the actual Abbe limit of 12 nm, which is the highest resolution achieved from any table-top extreme ultraviolet (XUV) or x-ray microscope. In addition, sub-30 nm resolution was achieved with only 3 s of integration time, bringing live diffractive imaging and three-dimensional tomography on the nanoscale one step closer to reality. The current resolution is solely limited by the wavelength and the detector size. Thus, table-top nanoscopes with only a few-nanometer resolutions are in reach and will find applications in many areas of science and technology.

2.
Sci Rep ; 4: 7356, 2014 Dec 08.
Article in English | MEDLINE | ID: mdl-25483626

ABSTRACT

Coherent Diffraction Imaging is a technique to study matter with nanometer-scale spatial resolution based on coherent illumination of the sample with hard X-ray, soft X-ray or extreme ultraviolet light delivered from synchrotrons or more recently X-ray Free-Electron Lasers. This robust technique simultaneously allows quantitative amplitude and phase contrast imaging. Laser-driven high harmonic generation XUV-sources allow table-top realizations. However, the low conversion efficiency of lab-based sources imposes either a large scale laser system or long exposure times, preventing many applications. Here we present a lensless imaging experiment combining a high numerical aperture (NA = 0.8) setup with a high average power fibre laser driven high harmonic source. The high flux and narrow-band harmonic line at 33.2 nm enables either sub-wavelength spatial resolution close to the Abbe limit (Δr = 0.8λ) for long exposure time, or sub-70 nm imaging in less than one second. The unprecedented high spatial resolution, compactness of the setup together with the real-time capability paves the way for a plethora of applications in fundamental and life sciences.

3.
Opt Lett ; 37(23): 4910-2, 2012 Dec 01.
Article in English | MEDLINE | ID: mdl-23202087

ABSTRACT

It is shown that timing jitter in optical parametric chirped-pulse amplification induces spectral drifts that transfer to carrier-envelope phase (CEP) instabilities via dispersion. Reduction of this effect requires temporal synchronization, which is realized with feedback obtained from the angularly dispersed idler. Furthermore, a novel method to measure the CEP drifts by utilizing parasitic second harmonic generation within parametric amplifiers is presented. Stabilization of the timing allows the obtainment of a CEP stability of 86 mrad over 40 min at 150 kHz repetition rate.

4.
Opt Express ; 19(20): 19374-83, 2011 Sep 26.
Article in English | MEDLINE | ID: mdl-21996878

ABSTRACT

The process of high harmonic generation allows for coherent transfer of infrared laser light to the extreme ultraviolet spectral range opening a variety of applications. The low conversion efficiency of this process calls for optimization or higher repetition rate intense ultrashort pulse lasers. Here we present state-of-the-art fiber laser systems for the generation of high harmonics up to 1 MHz repetition rate. We perform measurements of the average power with a calibrated spectrometer and achieved µW harmonics between 45 nm and 61 nm (H23-H17) at a repetition rate of 50 kHz. Additionally, we show the potential for few-cycle pulses at high average power and repetition rate that may enable water-window harmonics at unprecedented repetition rate.


Subject(s)
Amplifiers, Electronic , Energy Transfer , Lasers , Light , Models, Theoretical , Oscillometry/methods , Scattering, Radiation , Computer Simulation , Equipment Design , Signal Processing, Computer-Assisted/instrumentation
5.
Opt Express ; 19(18): 16797-808, 2011 Aug 29.
Article in English | MEDLINE | ID: mdl-21935041

ABSTRACT

The influence of parasitic processes on the performance of ultra-broadband noncollinear optical parametric amplifiers (NOPA's) is investigated for walk-off and non-walk-off compensating configurations. Experimental results with a white-light-seeded NOPA agree well with numerical simulations. The same model shows that 10% of the output energy of an amplified signal can be transferred into a parasitic second harmonic of the signal. These findings are supported by quantitative measurements on a few-cycle NOPA, where a few percent of the signal energy is converted to its second harmonic in the walk-off compensating case. This effect is reduced by an order of magnitude in the non-walk-off compensating configuration. A detailed study of the phase-matching conditions of the most common nonlinear crystals provides guidelines for designing NOPA systems.

SELECTION OF CITATIONS
SEARCH DETAIL
...