Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Beijing Da Xue Xue Bao Yi Xue Ban ; 55(5): 843-850, 2023 Oct 18.
Article in Chinese | MEDLINE | ID: mdl-37807738

ABSTRACT

OBJECTIVE: To investigate the imaging effect of a near-infrared fluorescent targeted probe ICG-NP41 on the neurovascular bundles (NVB) around the prostate in rats. METHODS: A near-infrared fluorescent targeted probe ICG-NP41 was synthesized. An animal model for NVB imaging was established using Sprague-Dawley rats (250-400 g). Experiments were conducted using a custom-built near-infrared windowⅡ(NIR-Ⅱ) small animal in vivo imaging system, and images collected were processed using ImageJ and Origin. The fluorescence signal data were statistically analyzed using GraphPad Prism. The signal-to-background ratio (SBR) for NVB was quantitatively calculated to explore the effective dosage and imaging time points. Finally, paraffin pathology sections and HE staining were performed on the imaging structures. RESULTS: Except for rats in the control group (n=2), right-sided NVB of the rats injected with ICG-NP41 (n=2 per group) were all observed in NIR-Ⅱ fluorescence mode 2 h and 4 h after administration. At 2 h and 4 h, average SBR of cavernous nerve in 2 mg/kg group in fluorescence mode was 1.651±0.142 and 1.619±0.110, respectively, both higher than that in white light mode (1.111±0.036), with no significant difference (P>0.05); average SBR of 4 mg/kg group in fluorescence mode were 1.168±0.066 and 1.219±0.118, respectively, both higher than that in white light mode (1.081±0.040), with no significant difference (P>0.05). At 2 h and 4 h, the average SBR of 2 mg/kg and 4 mg/kg groups in fluorescence mode were higher than that of the control group (SBR=1), the average SBR of the 2 mg/kg group was higher than that of the 4 mg/kg group, and all the above with no significant difference (P>0.05). The average diameter of the nerve measured by full width at half maxima method was about (178±15) µm. HE staining of paraffin sections showed the right major pelvic ganglion. CONCLUSION: The near-infrared fluorescent targeted probe ICG-NP41 can be used for real-time imaging of the NVB around the prostate in rats, providing a potential feasible solution for localizing NVB in real time during nerve-sparing radical prostatectomy.


Subject(s)
Paraffin , Prostate , Male , Rats , Animals , Prostate/diagnostic imaging , Indocyanine Green , Rats, Sprague-Dawley , Fluorescent Dyes
2.
Front Surg ; 9: 930160, 2022.
Article in English | MEDLINE | ID: mdl-35937604

ABSTRACT

Background: Anastomosing hemangioma (AH) is a rare vascular tumor and occurs in various organs. It is difficult to distinguish AH from malignant tumors even through multimodal imaging examination. AH located in the inguinal region is even rare. We present the diagnosis and treatment of a patient with spermatic cord AH in detail and conduct a literature review. Case Report: An 84-year-old Chinese man had swelling pain in his right scrotum. A hard and fixed mass was palpable in the right inguinal region. Preoperative radiological examination considered it a neurogenic or vascular tumor. Malignant soft tissue sarcoma could not be excluded. He underwent radical inguinal right orchiectomy under intraspinal anesthesia. The diagnosis of spermatic cord AH was confirmed by pathological examination. The patient recovered uneventfully and remained disease-free during an 18-month follow-up. Conclusion: Spermatic cord AH is quite rare and could be misdiagnosed as a malignant tumor. Pathological evidence might be necessary. The optimal choice of treatment should be determined through a comprehensive assessment of both tumor and patient factors.

3.
RSC Adv ; 12(33): 21609-21620, 2022 Jul 21.
Article in English | MEDLINE | ID: mdl-35975058

ABSTRACT

The therapeutic effect of photodynamic therapy (PDT) is highly dependent on the intracellular production of reactive oxygen species (ROS). However, the ROS generated by photosensitizers can be consumed by the highly concentrated glutathione (GSH) in tumor cells, severely impairing the therapeutic effect of PDT. Herein, we synthesized a GSH-scavenging copolymer to deliver photosensitizer chlorin e6 (Ce6). The pyridyl disulfide groups, which have faster reactivity with the thiol groups of GSH than other disulfide groups, were grafted onto a hydrophobic block to encapsulate the Ce6. Under NIR irradiation, the Ce6 generated ROS to kill tumor cells, and the pyridyl disulfide groups depleted the GSH to prevent ROS consumption, which synergistically enhanced the therapeutic effect of PDT. In vitro and in vivo experiments confirmed the combinatory antitumor effect of Ce6-induced ROS generation and the pyridyl disulfide group-induced GSH depletion. Therefore, the pyridyl disulfide group-grafted amphiphilic copolymer provides a more efficient strategy for enhancing PDT and has promising potential for clinical application.

SELECTION OF CITATIONS
SEARCH DETAIL
...