Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
ACS Appl Mater Interfaces ; 16(24): 30755-30765, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38847111

ABSTRACT

In recent years, enveloped micro-nanobubbles have garnered significant attention in research due to their commendable stability, biocompatibility, and other notable properties. Currently, the preparation methods of enveloped micro-nanobubbles have limitations such as complicated preparation process, large bubble size, wide distribution range, low yield, etc. There exists an urgent demand to devise a simple and efficient method for the preparation of enveloped micro-nanobubbles, ensuring both high concentration and a uniform particle size distribution. Magnetic lipid bubbles (MLBs) are a multifunctional type of enveloped micro-nanobubble combining magnetic nanoparticles with lipid-coated bubbles. In this study, MLBs are prepared simply and efficiently by a magneto internal heat bubble generation process based on the interfacial self-assembly of iron oxide nanoparticles induced by the thermogenic effect in an alternating magnetic field. The mean hydrodynamic diameter of the MLBs obtained was 384.9 ± 8.5 nm, with a polydispersity index (PDI) of 0.248 ± 0.021, a zeta potential of -30.5 ± 1.0 mV, and a concentration of (7.92 ± 0.46) × 109 bubbles/mL. Electron microscopy results show that the MLBs have a regular spherical stable core-shell structure. The superparamagnetic iron oxide nanoparticles (SPIONs) and phospholipid layers adsorbed around the spherical gas nuclei of the MLBs, leading the particles to demonstrate commendable superparamagnetic and magnetic properties. In addition, the effects of process parameters on the morphology of MLBs, including phospholipid concentration, phospholipid proportiona, current intensity, magnetothermal time, and SPION concentration, were investigated and discussed to achieve controlled preparation of MLBs. In vitro imaging results reveal that the higher the concentration of MLBs loaded with iron oxide nanoparticles, the better the in vitro ultrasound (US) imaging and magnetic resonance imaging (MRI) results. This study proves that the magneto internal heat bubble generation process is a simple and efficient technique for preparing MLBs with high concentration, regular structure, and commendable properties. These findings lay a robust foundation for the mass production and application of enveloped micro-nanobubbles, particularly in biomedical fields and other related domains.


Subject(s)
Phospholipids , Phospholipids/chemistry , Particle Size , Magnetic Iron Oxide Nanoparticles/chemistry , Magnetite Nanoparticles/chemistry , Gases/chemistry , Microbubbles , Magnetic Fields
2.
World J Gastrointest Surg ; 15(7): 1388-1396, 2023 Jul 27.
Article in English | MEDLINE | ID: mdl-37555112

ABSTRACT

BACKGROUND: As ultrasound-guided percutaneous liver biopsy (PLB) has become a standard and important method in the management of liver disease in our country, a periodical audit of the major complications is needed. AIM: To determine the annual incidence of major complications following ultrasound-guided PLB and to identify variables that are significantly associated with an increased risk of major complications. METHODS: A total of 1857 consecutive cases of PLB were included in our hospital from January 2021 to December 2021. The major complication rate and all-cause 30-d mortality rate were determined. Multivariate analyses were performed by logistic regression to investigate the risk factors associated with major complications and all-cause 30-d mortality following ultrasound-guided PLB. RESULTS: In this audit of 1857 liver biopsies, 10 cases (0.53%) of major complications occurred following ultrasound-guided PLB. The overall all-cause mortality rate at 30 d after PLB was 0.27% (5 cases). Two cases (0.11%) were attributed to major hemorrhage within 7 d after liver biopsy. Fibrinogen less than 2 g/L [odds ratio (OR): 17.226; 95% confidence interval (CI): 2.647-112.102; P = 0.003], post-biopsy hemoglobin level (OR: 0.963; 95%CI: 0.942-0.985; P = 0.001), obstructive jaundice (OR: 6.698; 95%CI: 1.133-39.596; P = 0.036), application of anticoagulants/antiplatelet medications (OR: 24.078; 95%CI: 1.678-345.495; P = 0.019) and age (OR: 1.096; 95%CI: 1.012-1.187; P = 0.025) were statistically associated with the incidence of major complications after PLB. CONCLUSION: In conclusion, the results of this annual audit confirmed that ultrasound-guided PLB can be performed safely, with a major complication rate within the accepted range. Strict patient selection and peri-biopsy laboratory assessment are more important than procedural factors for optimizing the safety outcomes of this procedure.

3.
Scand J Gastroenterol ; 58(5): 558-564, 2023 05.
Article in English | MEDLINE | ID: mdl-36415178

ABSTRACT

OBJECTIVES: Liver tumor in the caudate lobe is challenging to treat, partly due to its deep location. Endoscopic ultrasound-guided laser ablation (EUS-LA) is a new attractive option for tumors in high-risk or difficult-to-reach locations. This prospective study investigated the long-term efficacy of EUS-LA for tumors in the caudate lobe, and factors that predict outcomes. METHODS: From June 2016 to July 2021, twenty consecutive patients (aged 56.95 ± 10.06 years) with 25 caudate lobe tumors (15.64 ± 6.37 mm) underwent EUS-LA. Treatment outcomes were assessed and predictive factors were calculated via univariate and multivariate analyses. RESULTS: Twenty-five tumors achieved complete ablation after the first or second session of EUS-LA. The treatment effectiveness was 100%. During a median follow up of 27 months (3-60), four tumors (16%) developed local tumor progression and 15 patients (75%) experienced intrahepatic distant recurrence. According to univariate and multivariate analyses, the significant prognostic factor of local tumor progression was tumor size >2 cm (p = 0.047). Significant prognostic factors of intrahepatic distant recurrence were: tumor number, alpha-fetoprotein level, and total bilirubin level (p = 0.020, 0.019, 0.010, respectively). No adverse events related to EUS-LA were observed. CONCLUSION: EUS-LA is a viable, safe, and effective treatment option for patients with liver tumor in the caudate lobe. Tumor size >2 cm increases the risk of post-procedural local tumor progression. Intrahepatic tumor number, and pretreatment alpha-fetoprotein level and total bilirubin level are associated with intrahepatic distant recurrence. REGISTRATION: Clinicaltrials.gov, ID: NCT02816944(June 29, 2016).


Subject(s)
Carcinoma, Hepatocellular , Catheter Ablation , Laser Therapy , Liver Neoplasms , Humans , Prospective Studies , alpha-Fetoproteins , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Liver Neoplasms/etiology , Treatment Outcome , Ultrasonography, Interventional , Bilirubin , Retrospective Studies , Catheter Ablation/adverse effects , Carcinoma, Hepatocellular/etiology
4.
Front Oncol ; 12: 973652, 2022.
Article in English | MEDLINE | ID: mdl-36276094

ABSTRACT

In recent year, many deep learning have been playing an important role in the detection of cancers. This study aimed to real-timely differentiate a pancreatic cancer (PC) or a non-pancreatic cancer (NPC) lesion via endoscopic ultrasonography (EUS) image. A total of 1213 EUS images from 157 patients (99 male, 58 female) with pancreatic disease were used for training, validation and test groups. Before model training, regions of interest (ROIs) were manually drawn to mark the PC and NPC lesions using Labelimage software. Yolov5m was used as the algorithm model to automatically distinguish the presence of pancreatic lesion. After training the model based on EUS images using YOLOv5, the parameters achieved convergence within 300 rounds (GIoU Loss: 0.01532, Objectness Loss: 0.01247, precision: 0.713 and recall: 0.825). For the validation group, the mAP0.5 was 0.831, and mAP@.5:.95 was 0.512. In addition, the receiver operating characteristic (ROC) curve analysis showed this model seemed to have a trend of more AUC of 0.85 (0.665 to 0.956) than the area under the curve (AUC) of 0.838 (0.65 to 0.949) generated by physicians using EUS detection without puncture, although pairwise comparison of ROC curves showed that the AUC between the two groups was not significant (z= 0.15, p = 0.8804). This study suggested that the YOLOv5m would generate attractive results and allow for the real-time decision support for distinction of a PC or a NPC lesion.

5.
J Cancer Res Ther ; 16(5): 1100-1105, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33004754

ABSTRACT

OBJECTIVE: The objective is to evaluate the application of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) in the diagnosis of the left-lobe hepatocellular carcinoma (HCC) in cirrhotic patients with contraindication to percutaneous biopsy. MATERIALS AND METHODS: Thirty-eight consecutive patients with liver cirrhosis and suspected left-lobe HCC and with contraindication for percutaneous biopsy undergoing EUS-FNB between January 2011 and December 2014 were included in this study. The final diagnosis was obtained through histopathology of surgical samples or clinical and imaging results with follow-up. Using the final diagnosis as the gold standard, the diagnostic performance of EUS-FNB for HCC detection was evaluated. RESULTS: Among 38 patients, EUS-FNB was successfully performed in 34 cases, in which adequate biopsy specimens were obtained for histopathological examination in 30. For the 30 patients with biopsy results, 25 cases were confirmed to have HCC, while five cases had benign lesions according to the final diagnosis. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy rates of EUS-FNB in the diagnosis of HCC were 88.0% (22/25), 100.0% (5/5), 100.0% (22/22), 62.5% (5/8), and 90.0% (27/30), respectively. Self-limiting bleeding occurred in three patients. CONCLUSIONS: EUS-FNB is a sensitive and safe diagnostic modality for cirrhotic patients with suspected HCC located in the left lobe, especially those for whom percutaneous biopsy is contraindicated.


Subject(s)
Carcinoma, Hepatocellular/diagnosis , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Image-Guided Biopsy/methods , Liver Cirrhosis/physiopathology , Liver Neoplasms/diagnosis , Carcinoma, Hepatocellular/diagnostic imaging , Diagnosis, Differential , Female , Humans , Liver Neoplasms/diagnostic imaging , Male , Middle Aged , ROC Curve , Retrospective Studies
7.
Cancer Biol Ther ; 19(3): 145-152, 2018 03 04.
Article in English | MEDLINE | ID: mdl-29303406

ABSTRACT

Endoscopic ultrasound (EUS) have been not only a diagnostic tool, but also available in interventional therapy, which often previously needed surgical approaches to achieve. The study aimed to evaluate the effectiveness and safety of EUS-guided Nd:YAG laser ablation in unresectable tumors of the caudate lobe and left liver. We discussed ten cases of the caudate lobe and left liver tumors underwent laser ablation with EUS guidance. And we also have reviewed previous publication of EUS-guided thermal ablation for liver tumors in several decade years. EUS-guided Nd:YAG laser ablation (LA) of these tumors were successfully completed in ten patients, who had favourable prognosis with no complications in two-month follow-up. Based on our early observations, this suggested that EUS-guided LA might be technically feasible in selected patients with tumors of the caudate lobe and left liver. However, the safety of this technique need to be further confirmed in the future and if possible larger, prospective trials.


Subject(s)
Endosonography/methods , Laser Therapy/methods , Liver Neoplasms/surgery , Ultrasonography, Interventional/methods , Aged , Endosonography/adverse effects , Feasibility Studies , Female , Humans , Laser Therapy/adverse effects , Laser Therapy/instrumentation , Lasers, Solid-State/therapeutic use , Liver/diagnostic imaging , Liver/pathology , Liver/surgery , Liver Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Male , Middle Aged , Prospective Studies , Treatment Outcome , Ultrasonography, Interventional/adverse effects
8.
Clin Gastroenterol Hepatol ; 16(8): 1314-1321, 2018 08.
Article in English | MEDLINE | ID: mdl-28733257

ABSTRACT

BACKGROUND & AIMS: Endoscopic ultrasound (EUS)-guided fine needles with side fenestrations are used to collect aspirates for cytology analysis and biopsy samples for histologic analysis. We conducted a large, multicenter study to compare the accuracy of diagnosis via specimens collected with fine-needle biopsy (FNB) versus fine-needle aspiration (FNA) for patients with pancreatic and nonpancreatic masses. METHODS: We performed a prospective single-blind study at 5 tertiary care centers in China. The study comprised 408 patients undergoing EUS for a solid mass (>1 cm) in the pancreas, abdomen, mediastinum, or pelvic cavity, from December 2014 through January 2016. Patients were randomly assigned to groups (1:1) for assessment by FNA (n = 190) or FNB (n = 187). After lesions were identified by EUS, samples were collected in a total of 4 passes by each needle. All procedures were performed by experienced endosonographers; cytologists and pathologists were blinded to the sample collection method. Patients were followed for at least 48 weeks, and final diagnoses were obtained after surgery, imaging analysis, or resolution of lesion. The primary aim was to compare diagnostic yields of EUS-FNA with EUS-FNB for all solid masses, then separately as pancreatic and nonpancreatic masses. The secondary endpoint was the quality of histologic specimen. RESULTS: Findings from FNB analysis were accurate for 91.44% of all cases, compared with 80.00% for all FNA cases, based on final patient diagnoses (P = .0015). In patients with pancreatic masses (n = 249), findings from histologic analysis of FNBs were accurate for 92.68% of the cases, compared with 81.75% for FNAs (P = .0099). In cytology analysis of pancreatic masses, samples collected by FNB accurately identified 88.62% of all pancreatic lesions, whereas samples collected by FNA accurately identified 79.37% (P = .00468). Analyses of samples of nonpancreatic masses collected by FNA versus FNB produced similar diagnostic yields. CONCLUSIONS: In a prospective study of patients with pancreatic masses, we found EUS-guided FNB samples to produce more accurate diagnoses than samples collected by EUS-guided FNA samples. No difference in diagnostic yield was seen between EUS-FNA and EUS-FNB for nonpancreatic masses. Clinical Trials.gov no: NCT02327065.


Subject(s)
Abdominal Neoplasms/diagnosis , Biopsy, Fine-Needle/methods , Mediastinal Neoplasms/diagnosis , Pancreatic Neoplasms/diagnosis , Pelvic Neoplasms/diagnosis , Aged , Aged, 80 and over , China , Female , Humans , Male , Middle Aged , Prospective Studies , Single-Blind Method , Tertiary Care Centers
9.
Oncotarget ; 8(2): 2413-2422, 2017 Jan 10.
Article in English | MEDLINE | ID: mdl-27974691

ABSTRACT

BACKGROUND & AIMS: Metastasis in retroperitoneal lymph nodes is one of the signs of advanced stage or terminal stage of malignancy. We performed a trial to assess the safety and efficacy of ultrasonography (US)-guided local neodymium-doped yttrium aluminum garnet (Nd:YAG) laser ablation for metastatic lymph nodes in the retroperitoneal region. METHODS: We evaluated 4 cases of retroperitoneal metastatic lymph nodes treated using US-guided Nd:YAG laser ablation. Additionally, we reviewed the PubMed database for articles on thermal ablation of retroperitoneal lesions until March 2016, without language limitations. RESULTS: In our study, all lesions were nearly completely ablated with mild discomfort, including pain and fever at the 3-month follow-up. In the literature review, a total of 398 patients with 491 retroperitoneal tumors were identified, and complications after the procedure included enterovesical fistula, fecal incontinence, and hematoma. CONCLUSIONS: Percutaneous laser ablation could be a theoretically promising approach for retroperitoneal metastatic lesions. ClinicalTrials.gov number: NCT02822053.


Subject(s)
Laser Therapy/instrumentation , Retroperitoneal Neoplasms/diagnostic imaging , Retroperitoneal Neoplasms/surgery , Adult , Humans , Lasers, Solid-State , Lymphatic Metastasis , Male , Middle Aged , Treatment Outcome , Ultrasonography
10.
Sci Rep ; 6: 36098, 2016 12 13.
Article in English | MEDLINE | ID: mdl-27958384

ABSTRACT

This study aimed to compare the efficacy and safety of EUS-guided ethanol injection and 125I seed brachytherapy for malignant left-sided liver tumors which were difficult for trans-abdominal intervention. The study protocol was registered at Clinicaltrials.gov (NCT02816944). Twenty-six patients were consecutively and prospectively hospitalized for EUS-guided interventional treatment of refractory malignant left-sided liver tumors between June 2014 and June 2016. Liver masses were detected using EUS in 25 of 26 (96.2%) patients. EUS-guided interventional treatment was completed uneventfully in 23 of 26 (88.5%) patients using anhydrous ethanol injection (n = 10) or iodine-125 seed implantation (n = 13). Six months later, complete response was achieved in 15 of 23 (65.2%) patients and partial response in 8 of 23 (34.8%) patients. Patients with tumor residual have second-look EUS-guided interventional treatment (n = 5), radiotherapy (n = 2) or surgical resection (n = 1). Complete response was achieved after repeated interventional treatment in 3 of 5 patients who underwent second EUS-guided intervention; 2 patients required additional surgical resection but one succeed. No significant complications occurred. Therefore EUS-guided 125I seed brachytherapy is an effective and safe treatment modality for radical operation or promising palliative control of malignant left-sided liver tumors refractory to trans-abdominal intervention.


Subject(s)
Antineoplastic Agents/administration & dosage , Antineoplastic Agents/adverse effects , Endosonography/adverse effects , Endosonography/methods , Ethanol/administration & dosage , Iodine Radioisotopes/administration & dosage , Liver Neoplasms/therapy , Adult , Ethanol/adverse effects , Female , Humans , Iodine Radioisotopes/adverse effects , Liver/pathology , Male , Middle Aged , Prospective Studies , Treatment Outcome
11.
J Ultrasound Med ; 33(3): 449-55, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24567456

ABSTRACT

OBJECTIVES: The purpose of this study was to determine whether contrast-enhanced sonography can improve the ability to differentiate branch duct intraductal mucinous neoplasms from serous cystadenomas of the pancreas compared to conventional (unenhanced) sonography alone. METHODS: Between March 2008 and May 2012, there were 20 patients with branch duct intraductal mucinous neoplasms and 25 with serous cystadenomas in our institute, for whom preoperative conventional and contrast-enhanced sonographic results were available. The final diagnosis was obtained by histopathology. Various conventional and contrast-enhanced sonographic characteristics were retrospectively evaluated by 2 radiologists in consensus. A receiver operating characteristic curve analysis was used to evaluate the diagnostic value of conventional and contrast-enhanced sonography for discriminating between the two entities. RESULTS: Three conventional sonographic characteristics (microcysts, cysts with internal echoes, and main pancreatic duct dilatation) and 2 contrast-enhanced sonographic characteristics (communication between the lesion and main pancreatic duct and enhancement of mural nodules) significantly improved the ability to differentiate branch duct intraductal mucinous neoplasms from serous cystadenomas. The area under the receiver operating characteristic curve increased from 0.691 with conventional sonography to 0.859 with combined contrast-enhanced and conventional ultrasonography (P = .043). CONCLUSIONS: In this series of patients, the addition of contrast-enhanced sonography to conventional sonography improved the ability to differentiate branch duct intraductal mucinous neoplasms from serous cystadenomas.


Subject(s)
Adenocarcinoma, Mucinous/diagnostic imaging , Adenocarcinoma, Papillary/diagnostic imaging , Carcinoma, Pancreatic Ductal/diagnostic imaging , Cystadenoma, Serous/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Phospholipids , Sulfur Hexafluoride , Ultrasonography/methods , Aged , Contrast Media , Diagnosis, Differential , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Observer Variation , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...