Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Air Qual Atmos Health ; 11(2): 163-170, 2018.
Article in English | MEDLINE | ID: mdl-29568336

ABSTRACT

In recent years, research into the efficacy of indoor air biofiltration mechanisms, notably living green walls, has become more prevalent. Whilst green walls are often utilised within the built environment for their biophilic effects, there is little evidence demonstrating the efficacy of active green wall biofiltration for the removal of volatile organic compounds (VOCs) at concentrations found within an interior environment. The current work describes a novel approach to quantifying the VOC removal effectiveness by an active living green wall, which uses a mechanical system to force air through the substrate and plant foliage. After developing a single-pass efficiency protocol to understand the immediate effects of the system, the active green wall was installed into a 30-m3 chamber representative of a single room and presented with the contaminant 2-butanone (methyl ethyl ketone; MEK), a VOC commonly found in interior environments through its use in textile and plastic manufacture. Chamber inlet levels of MEK remained steady at 33.91 ± 0.541 ppbv. Utilising a forced-air system to draw the contaminated air through a green wall based on a soil-less growing medium containing activated carbon, the combined effects of substrate media and botanical component within the biofiltration system showed statistically significant VOC reduction, averaging 57% single-pass removal efficiency over multiple test procedures. These results indicate a high level of VOC removal efficiency for the active green wall biofilter tested and provide evidence that active biofiltration may aid in reducing exposure to VOCs in the indoor environment.

2.
Perspect Public Health ; 133(3): 158-64, 2013 May.
Article in English | MEDLINE | ID: mdl-22833542

ABSTRACT

INTRODUCTION: It has been recognised that as outdoor ambient temperatures increase past a particular threshold, so do mortality/morbidity rates. However, similar thresholds for indoor temperatures have not yet been identified. Due to a warming climate, the non-sustainability of air conditioning as a solution, and the desire for more energy-efficient airtight homes, thresholds for indoor temperature should be defined as a public health issue. AIMS: The aim of this paper is to outline the need for indoor heat thresholds and to establish if they can be identified. Our objectives include: describing how indoor temperature is measured; highlighting threshold measurements and indices; describing adaptation to heat; summary of the risk of susceptible groups to heat; reviewing the current evidence on the link between sleep, heat and health; exploring current heat and health warning systems and thresholds; exploring the built environment and the risk of overheating; and identifying the gaps in current knowledge and research. METHODS: A global literature search of key databases was conducted using a pre-defined set of keywords to retrieve peer-reviewed and grey literature. The paper will apply the findings to the context of the UK. RESULTS: A summary of 96 articles, reports, government documents and textbooks were analysed and a gap analysis was conducted. Evidence on the effects of indoor heat on health implies that buildings are modifiers of the effect of climate on health outcomes. Personal exposure and place-based heat studies showed the most significant correlations between indoor heat and health outcomes. However, the data are sparse and inconclusive in terms of identifying evidence-based definitions for thresholds. Further research needs to be conducted in order to provide an evidence base for threshold determination. CONCLUSIONS: Indoor and outdoor heat are related but are different in terms of language and measurement. Future collaboration between the health and building sectors is needed to develop a common language and an index for indoor heat and health thresholds in a changing climate.


Subject(s)
Air Conditioning/standards , Health Status , Heating/standards , Hot Temperature/adverse effects , Housing/standards , Age Factors , Air Conditioning/adverse effects , Air Conditioning/trends , Building Codes/standards , Climate Change , Heating/adverse effects , Humans , Renewable Energy/standards , Sleep/physiology , United Kingdom
3.
Perspect Public Health ; 130(5): 233-8, 2010 Sep.
Article in English | MEDLINE | ID: mdl-21086820

ABSTRACT

The U.K. government has committed to an 80% reduction in carbon emissions by 2050, with housing accounting for 27% of total current emissions. There are several drivers both to reduce emissions from homes and to reduce fuel poverty, promoting a range of building and behavioural measures in homes. The health benefits of warmer homes in winter have been described, but there has been less consideration of the potential negative impacts of some of these measures. We examine the changes in U.K. homes, and the possible consequences for health. The main concerns for health surround the potential for poor indoor air quality if ventilation is insufficient and the possible risks of overheating in heatwave conditions. This paper notes a limited evidence base and the need for further research on the health effects of energy-efficient homes, particularly with regard to ventilation.


Subject(s)
Air Pollution, Indoor/adverse effects , Air Pollution, Indoor/prevention & control , Conservation of Energy Resources/methods , Housing/standards , Humans , Public Health Practice , United Kingdom , Ventilation/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...