1.
J Interv Cardiol ; 17(3): 143-9, 2004 Jun.
Article in English | MEDLINE | ID: mdl-15209576

ABSTRACT

PURPOSE: The purpose of this analysis was to evaluate if overdosage during intracoronary irradiation due to overlapped source stepping may result in long-term morphologic changes in vessel anatomy. METHODS: Baseline angiograms of patients with in-stent restenosis undergoing coronary reintervention followed by intracoronary irradiation with source stepping were analyzed. Overlapping was considered present for the segment with overlapped reference isodose length (RIL) (RIL = segment with > or = 90% of reference dose at 1 mm vessel wall depth). Baseline and 6-months follow-up volumetric intravascular ultrasound (IVUS) analysis were performed for the overlapped segment and for proximal and distal segments of equal length. RESULTS: Overlapping was found in six patients (three patients: (32)P treatment; three patients: (90)Sr/Y treatment); final analysis was performed in four patients. Comparison of the baseline and follow-up IVUS volumetric parameters revealed no significant change in lumen or vessel volumes at segments of overlaps in comparison to proximal and distal reference segments. CONCLUSION: Increased dosage due to overlapping during source stepping is not associated with morphologic changes in vessel anatomy at follow-up.


Subject(s)
Coronary Restenosis/therapy , Coronary Vessels/radiation effects , Phosphorus Radioisotopes/administration & dosage , Strontium Radioisotopes/administration & dosage , Angioplasty, Balloon , Coronary Vessels/diagnostic imaging , Dose-Response Relationship, Radiation , Humans , Imaging, Three-Dimensional , Phosphorus Radioisotopes/adverse effects , Prospective Studies , Strontium Radioisotopes/adverse effects , Ultrasonography, Interventional
2.
Can J Cardiol ; 19(6): 691-7, 2003 May.
Article in English | MEDLINE | ID: mdl-12772020

ABSTRACT

OBJECTIVE: To analyze possible associations between radial stretch during coronary angioplasty and the incidence of target lesion revascularization (TLR). PATIENTS AND METHODS: Intravascular ultrasound images were obtained before and after revascularization in 182 native coronary lesions. The quantitative intravascular ultrasound parameters (external elastic membrane cross-sectional area [EEM-A], lumen areas [LA], plaque area [PA], calculated as EEM-A-LA, and changes between pre- and postinterventional LA [DLA], EEM-A [DEEM-A] and PA [DPA]) were correlated with the incidence of TLR. RESULTS: TLR was performed in 60 (33%) patients, while 122 (67%) patients remained event free. Postinterventional PA remained significantly larger in the TLR group than in the event-free group (9.2 +/- 3.3 mm2 versus 7.9 +/- 3.3 mm2; P=0.02). The radial stretch during intervention, expressed as DEEM-A, and the balloon to artery ratio was significantly larger in the TLR group (DEEM-A: 1.9 +/- 2.1 mm2 versus 1.3 +/- 2.0 mm2; P=0.03; balloon to artery ratio: 1.3 +/- 0.2 versus 1.0 +/- 0.5; P=0.04). Multivariate analysis revealed DEEM-A (P=0.01), DPA (P=0.03), diabetes (P=0.001, odds ratio 5.2, 95% CI 4.9 to 6.5) and adaptive remodelling (P<0.001, odds ratio 4.1, 95% CI 3.5 to 6.4) as independent predictors for TLR. CONCLUSION: Whereas patients in whom lumen gain is achieved primarily by plaque reduction with less wall stretch tend to remain event free, patients with significant radial stretch (ie, less reduction of the PA, but a radial outward shift of the plaque mass) experience a higher incidence of TLR.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Vessels/diagnostic imaging , Myocardial Revascularization , Ultrasonography, Interventional , Aged , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/surgery , Female , Humans , Male
3.
Am J Hypertens ; 16(5 Pt 1): 356-62, 2003 May.
Article in English | MEDLINE | ID: mdl-12745196

ABSTRACT

BACKGROUND: Previous studies have shown atherogenesis to be related with increased vessel stiffness. Measures of the arterial compliance can be performed noninvasively from pressure pulse contour analysis of arterial waveforms. In this prospective study we aimed to analyze to what extent vessel compliance can reflect the angiographic coronary artery status. METHODS: Large and small arterial elasticity indices (LAEI in milliliters per mm Hg x 10 and SAEI in milliliters per mm Hg x 100) were measured in 151 patients on the radial artery with the PulseWave Sensor HDI device. All patients were classified into diffuse-coronary artery disease (CAD) (defined as stenosis length >15 mm), focal-CAD (defined as stenosis length between 1 and 15 mm), or no-CAD. RESULTS: We found both LAEI and SAEI to be reduced in the diabetic group (LAEI: 11.2 +/- 2.9 v 13.4 +/- 4.5, P =.006; SAEI: 3.7 +/- 1.6 v 4.7 +/- 2.4, P =.01). Inverse association was seen between age and LAEI (r = -0.41; P <.001) and SAEI (r = -0.38; P <.001). No-CAD was found in 31 patients, focal-CAD in 64 patients, and diffuse-CAD in 56 patients. Mean LAEI were 13.8 +/- 3.5, 13.7 +/- 4.7, and 11.3 +/- 3.5 in the groups no-CAD, focal-CAD, and diffuse-CAD, respectively (P =.004), (no-CAD versus diffuse-CAD: P =.04; focal-CAD versus diffuse-CAD: P =.009). Respective SAEI values were 5.6 +/- 2.5, 5.0 +/- 2.1, and 3.1 +/- 1.6 (P <.001), (no-CAD versus diffuse-CAD: P <.001; focal-CAD versus diffuse-CAD: P <.001). Multivariate analysis revealed SAEI (P <.001), hypercholesterolemia (P =.005), systolic blood pressure (BP) (P <.001), mean arterial BP (P <.001), pulse pressure (P =.003), and male gender (P =.001) to be diagnostic markers of the type of vessel disease. CONCLUSIONS: Compliance measurements may be used for identification of patients with diffuse atherosclerotic processes of the coronary arteries.


Subject(s)
Coronary Artery Disease/physiopathology , Age Factors , Aged , Austria , Blood Pressure/physiology , Coronary Angiography , Coronary Artery Disease/diagnosis , Elasticity , Female , Humans , Hypercholesterolemia/diagnosis , Hypercholesterolemia/physiopathology , Hypertension/diagnosis , Hypertension/physiopathology , Male , Middle Aged , Multivariate Analysis , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity , Sex Factors , Statistics as Topic , Systole/physiology
4.
J Interv Cardiol ; 15(6): 477-83, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12476651

ABSTRACT

The implementation of coronary brachytherapy and especially the application of drug-eluting stents for the prevention of in-stent restenosis are of vital importance in the field of interventional cardiology. Despite undeniable benefits of these new methods a potential increased risk for the occurrence of stent thrombosis as a result of the mode of action of these new methods has to be taken into consideration. The prevention of stent thrombosis following coronary brachytherapy and implantation of drug-eluting stents is therefore of particular importance to assure the success of these forward-looking technologies. This article provides an overview of current data regarding the incidence of stent thrombosis following brachytherapy and implantation of drug-eluting stents and it's implication for clinical practice.


Subject(s)
Brachytherapy/adverse effects , Coronary Thrombosis/prevention & control , Drug Delivery Systems/adverse effects , Growth Inhibitors/adverse effects , Stents/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Coronary Restenosis/prevention & control , Humans
5.
Coron Artery Dis ; 13(5): 263-8, 2002 Aug.
Article in English | MEDLINE | ID: mdl-12394650

ABSTRACT

BACKGROUND: Diabetic patients show an increased incidence of restenosis after coronary angioplasty than non-diabetic patients. This may be because of differences in the mechanism of lumen gain during coronary revascularization in this population cohort. DESIGN: This study analyses the mechanism of lumen gain during coronary stent deployment in diabetic patients compared with non-diabetic patients with intravascular ultrasound (IVUS). METHODS: IVUS images were obtained prior to and after revascularization in 26 diabetic and 97 non-diabetic patients. The external elastic membrane cross-sectional area (EEM) and lumen cross-sectional area (LA) were measured. Plaque area (PA) was calculated as EEM minus LA. Differences between pre- and post-LA (deltaLA), EEM (deltaEEM) and PA (deltaPA) were calculated. RESULTS: Pre-interventional PA (diabetic patients: 12.4 +/- 4.4 mm2 compared with non-diabetic patients: 10.7 +/- 3.6 mm2, = 0.04) and pre-interventional EEM (15.5 +/- 4.4 mm2 compared with 13.6 +/- 3.7 mm2 respectively, P = 0.02) were larger in the diabetic group. Postinterventional PA (10.2 +/- 3.2 mm2 compared with 8.0 +/- 3.4 mm2, P = 0.004) was also larger and postinterventional LA (6.3 +/- 2.2 mm2 compared with 7.4 +/- 2.4 mm2 = 0.04), deltaEEM (0.9 +/- 1.8 mm2 compared with 1.8 +/- 1.8 mm2 P = 0.04) and deltaLA (3.1 +/- 1.6 mm2 compared with 4.2 +/- 2.2 mm2, P = 0.03) were smaller in the diabetic group. The diabetic group exhibited longer lesion lengths (P = 0.04) and a higher inflation pressure was used during revascularization in this patient cohort (P = 0.02). CONCLUSION: Diabetic patients have less reduction of PA during revascularization and because the vessel wall cannot be stretched outwards despite higher inflation pressure, postinterventional LA remains smaller than in the non-diabetic population cohort. This might be a rudiment for consideration of different treatment strategies such as cutting balloon or atherectomy prior to stenting in this population group in order to achieve better procedural outcome.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease/pathology , Coronary Artery Disease/therapy , Coronary Vessels/pathology , Diabetic Angiopathies/pathology , Diabetic Angiopathies/therapy , Stents , Ultrasonography, Interventional , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Diabetic Angiopathies/diagnostic imaging , Female , Humans , Male , Middle Aged
6.
J Am Coll Cardiol ; 40(7): 1225-31, 2002 Oct 02.
Article in English | MEDLINE | ID: mdl-12383569

ABSTRACT

OBJECTIVE: The goal of this study was to evaluate the incidence and effects of underdosage of injured segments during intracoronary irradiation and to define the minimal length of safety margin required to avoid mismatched source placement. BACKGROUND: Underdosage of injured segments due to misplacement of active source has been suggested as the underlying mechanism for the occurrence of edge restenosis. METHODS: Baseline angiograms of 112 vessels in 109 patients with in-stent restenosis undergoing coronary reintervention followed by intracoronary irradiation ((192)Ir: Checkmate, Cordis, Miami, Florida; (32)P: Gallileo, Guidant, Houston, Texas; (90)Sr/Y: Beta-Cath, Novoste, Norcross, Georgia) were analyzed. The distances between the outermost injury and outermost end of "reference isodose length" (RIL), defined as a segment with >/=90% of reference dose at 1 mm vessel wall depth, were measured. "Safety margin" was defined as the distance between the outermost injury and outermost end of the RIL, "geographical miss" (GM) as a complete injured segment not being covered by the RIL, and "restenosis" as the percent diameter stenosis >50%. RESULTS: Baseline angiographic analysis was performed for 224 edges in 112 vessels. Geographical miss was found in 46 (20.6%) edges. The incidence of target lesion restenosis within the 78 vessels with available follow-up was 43.3% for patients with GM versus 14.9% for patients with no GM (p = 0.005). Analysis of various injured segments exposed highest restenosis rates in injured segments with negligible irradiation (27.8%) in comparison with injured segments with dose fall-off (16.7%) or injured segments with full-dose irradiation (7.7%) (p = 0.006). Receiver operating curve analysis revealed a safety margin of 10 mm required per vessel (i.e., 5-mm safety margin/edge) to achieve 95% specificity of GM. CONCLUSIONS: Geographical miss is associated with a higher incidence of restenosis at the corresponding edges. Restenosis was more pronounced in injured segments with negligible irradiation than in injured segments at the dose fall-off zones. We recommend a safety margin of 10 mm per vessel to minimize GM.


Subject(s)
Beta Particles/therapeutic use , Coronary Stenosis/radiotherapy , Gamma Rays/therapeutic use , Myocardial Revascularization/adverse effects , Myocardial Revascularization/methods , Beta Particles/adverse effects , Coronary Angiography , Gamma Rays/adverse effects , Humans , Incidence , Iridium Radioisotopes/adverse effects , Iridium Radioisotopes/therapeutic use , Phosphorus Radioisotopes/adverse effects , Phosphorus Radioisotopes/therapeutic use , Prospective Studies , Radiation Protection/methods , Radiotherapy Dosage , Recurrence , Safety , Sensitivity and Specificity , Stents , Strontium Radioisotopes/adverse effects , Strontium Radioisotopes/therapeutic use , Treatment Outcome
7.
Circulation ; 105(20): 2355-60, 2002 May 21.
Article in English | MEDLINE | ID: mdl-12021220

ABSTRACT

BACKGROUND: In patients with acute coronary syndrome (ACS), percutaneous coronary intervention (PCI) may cause thrombus dislodgment followed by reduced flow and impaired microcirculatory function. We prospectively compared conventional PCI to a strategy of additional pretreatment using the X-sizer thrombectomy system. METHODS AND RESULTS: Sixty-six patients (51 [77%] men; 54.9+/-9.9 years) with ACS (49 with ST-elevation infarction [STEMI]) and suspected intracoronary thrombus were randomized 1:1 to pretreatment with X-sizer and conventional PCI alone. Various aspects of epicardial flow and microvascular function were studied. Baseline data were similar in both groups. Postprocedural TIMI 3 flow was obtained in 90% of X-sizer-treated patients and in 84% of controls (NS); however, corrected TIMI frame count was lower in X-sizer- treated patients (18.3+/-10.2 versus 24.7+/-14.1; P<0.05). No significant group differences were observed in final coronary flow reserve, myocardial blush grade, and myocardial dye intensity. In STEMI, the sum of ST elevation was significantly lower in X-sizer-treated patients immediately after (2.78+/-3.05 versus 6.15+/-6.32 mm; P<0.03) and 6 hours after (2.17+/-2.31 versus 4.14+/-3.7 mm; P<0.05) intervention. ST-segment resolution >50% was observed in 83% of X-sizer-treated patients and in 52% of controls (P<0.03). Multivariate analysis identified X-sizer treatment as the single independent predictor of ST-segment resolution >50% (OR 4.35; 95% CI, 1.13 to 16.9; P<0.04). Major adverse cardiac events after 30 days occurred in 2 patients in each group. CONCLUSIONS: In ACS with suspected thrombus, pretreatment with the X-sizer catheter system improves epicardial flow and accelerates ST-segment resolution compared with conventional PCI alone.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease/surgery , Coronary Vessels/physiopathology , Coronary Vessels/surgery , Electrocardiography , Thrombectomy/instrumentation , Acute Disease , Blood Flow Velocity , Coronary Angiography , Coronary Circulation , Embolism/prevention & control , Female , Humans , Male , Microcirculation/physiopathology , Middle Aged , Multivariate Analysis , Odds Ratio , Prospective Studies , Rheology , Thrombectomy/methods , Treatment Outcome