Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Intensive Care Med Exp ; 12(1): 25, 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38451334

ABSTRACT

BACKGROUND: Expiratory time constant (τ) objectively assesses the speed of exhalation and can guide adjustments of the respiratory rate and the I:E ratio with the goal of achieving complete exhalation. Multiple methods of obtaining τ are available, but they have not been compared. The purpose of this study was to compare six different methods to obtain τ and to test if the exponentially decaying flow corresponds to the measured time constants. METHODS: In this prospective study, pressure, flow, and volume waveforms of 30 postoperative patients undergoing volume (VCV) and pressure-controlled ventilation (PCV) were obtained using a data acquisition device and analyzed. τ was measured as the first 63% of the exhaled tidal volume (VT) and compared to the calculated τ as the product of expiratory resistance (RE) and respiratory system compliance (CRS), or τ derived from passive flow/volume waveforms using previously published equations as proposed by Aerts, Brunner, Guttmann, and Lourens. We tested if the duration of exponentially decaying flow during exhalation corresponded to the duration of the predicted second and third τ, based on multiples of the first measured τ. RESULTS: Mean (95% CI) measured τ was 0.59 (0.57-0.62) s and 0.60 (0.58-0.63) s for PCV and VCV (p = 0.45), respectively. Aerts method showed the shortest values of all methods for both modes: 0.57 (0.54-0.59) s for PCV and 0.58 (0.55-0.61) s for VCV. Calculated (CRS * RE) and Brunner's τ were identical with mean τ of 0.64 (0.61-0.67) s for PCV and 0.66 (0.63-069) s for VCV. Mean Guttmann's τ was 0.64 (0.61-0.68) in PCV and 0.65 (0.62-0.69) in VCV. Comparison of each τ method between PCV and VCV was not significant. Predicted time to exhale 95% of the VT (i.e., 3*τ) was 1.77 (1.70-1.84) s for PCV and 1.80 (1.73-1.88) s for VCV, which was significantly longer than measured values: 1.27 (1.22-1.32) for PCV and 1.30 (1.25-1.35) s for VCV (p < 0.0001). The first, the second and the third measured τ were progressively shorter: 0.6, 0.4 and 0.3 s, in both ventilation modes (p < 0.0001). CONCLUSION: All six methods to determine τ show similar values and are feasible in postoperative mechanically ventilated patients in both PCV and VCV modes.

2.
Eur Heart J Case Rep ; 7(11): ytad566, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38034940

ABSTRACT

Background: Paenibacillus constitutes a genus of gram-positive, facultatively anaerobic, rod-shaped bacteria that act as potentially opportunistic pathogens. With only a few documented case studies to date, Paenibacillus species are rarely the cause of a disease in humans. Case summary: We report a case involving a 64-year-old male with known mild mitral regurgitation, who presented with fever and dyspnoea. Initially treated with empirical antibiotics, his blood cultures cultivated Paenibacillus thiaminolyticus, a previously unreported cause of endocarditis. Transoesophageal echocardiography demonstrated vegetations on the both leaflets of mitral valve along with severe mitral regurgitation, thus confirming a diagnosis of endocarditis. The patient was referred for cardiac surgery; however, the procedure was delayed due to complications related to a known hepatic cyst and additionally contraction of COVID-19 infection. The patient subsequently underwent mitral valve replacement without complications. Discussion: Because of its rarity, guidelines to recommend specific antibiotics to treat Paenibacillus infective endocarditis are absent. To confirm the pathogen, molecular methods such as mass spectrometry or 16S rRNA sequencing are required. Early targeted antibiotic therapy and cardiac surgery are warranted to achieve good clinical outcomes.

3.
Turk J Emerg Med ; 23(2): 127-130, 2023.
Article in English | MEDLINE | ID: mdl-37169034

ABSTRACT

Ventricular septal defect (VSD) is a known complication after myocardial infarction associated with high mortality. Extracorporeal membrane oxygenation (ECMO) is being successfully used in patients with VSD as a bridge to definitive surgical repair. Although often the only possibility to stabilize hemodynamics and oxygenation, ECMO has many potential complications, carrying significant morbidity and mortality. Here, the patient presented with a postinfarct VSD on peripheral venoarterial ECMO who developed a dissection of the common iliac artery (CIA) on the 5th day after ECMO implantation. As a result, a sudden drop in ECMO flow has become evident along with high pressures in the arterial cannula. After a definitive diagnosis of a CIA lesion obstructing the blood flow was made, trans-ECMO endovascular repair of CIA was performed. Four days after endovascular repair, we encountered the same problem of decreased blood flow associated with stent kinking and were approached with another endovascular repair to re-establishing full ECMO flow.

4.
J Crit Care ; 73: 154174, 2023 02.
Article in English | MEDLINE | ID: mdl-36272279

ABSTRACT

PURPOSE: Potential negative implications associated with high respiratory rate (RR) are intrinsic positive end-expiratory pressure (PEEPi) generation, cardiovascular depression and possibly ventilator induced lung injury. Despite these negative consequences, optimal RR remains largely unknown. We hypothesized that without consideration of dynamics of lung emptying (i.e., the expiratory time constant [RCEXP]) clinician settings of RR may exceed the frequency needed for optimal lung emptying. MATERIALS AND METHODS: This prospective multicenter observational study measured RCEXP in 56 intensive care patients receiving pressure-controlled ventilation. We compared set RR to the one predicted with RCEXP (RRP). Also, the subgroup of patients with prolonged RCEXP was analyzed. RESULTS: Overall, the absolute mean difference between the set RR and RRP was 2.8 bpm (95% CI: 2.3-3.2). Twenty-nine (52%) patients had prolonged RCEXP (>0.8 s), mean difference between set RR and RRP of 3.1 bpm (95% CI: 2.3-3.8; p < 0.0001) and significantly higher PEEPi compared to those with RCEXP ≤ 0.8 s: 4.4 (95% CI: 3.6-5.2) versus 1.5 (95% CI: 0.9-2.0) cmH2O respectively, p < 0.0001. CONCLUSIONS: Use of RRP based on measured RCEXP revealed that the clinician-set RR exceeded that predicted by RCEXP in the majority of patients. Measuring RCEXP appears to be a useful variable for adjusting the RR during mandatory mechanical ventilation.


Subject(s)
Positive-Pressure Respiration , Respiratory Rate , Humans , Prospective Studies , Respiration, Artificial , Lung
5.
BMC Anesthesiol ; 22(1): 387, 2022 12 13.
Article in English | MEDLINE | ID: mdl-36513978

ABSTRACT

BACKGROUND: We hypothesized that the measured expiratory time constant (TauE) could be a bedside parameter for the evaluation of positive end-expiratory pressure (PEEP) settings in mechanically ventilated COVID-19 patients during pressure-controlled ventilation (PCV). METHODS: A prospective study was conducted including consecutively admitted adults (n = 16) with COVID-19-related ARDS requiring mechanical ventilation. A PEEP titration using PCV with a fixed driving pressure of 14 cmH2O was performed and TauE recorded at each PEEP level (0 to 18 cmH2O) in prone (n = 29) or supine (n = 24) positions. The PEEP setting with the highest TauE (TauEMAX) was considered to represent the best tradeoff between recruitment and overdistention. RESULTS: Two groups of patterns were observed in the TauE plots: recruitable (R) (75%) and nonrecruitable (NR) (25%). In the R group, the optimal PEEP and PEEP ranges were 8 ± 3 cmH2O and 6-10 cmH2O for the prone position and 9 ± 3 cmH2O and 7-12 cmH2O for the supine position. In the NR group, the optimal PEEP and PEEP ranges were 4 ± 4 cmH2O and 1-8 cmH2O for the prone position and 5 ± 3 cmH2O and 1-7 cmH2O for the supine position, respectively. The R group showed significantly higher optimal PEEP (p < 0.004) and PEEP ranges (p < 0.001) than the NR group. Forty-five percent of measurements resulted in the most optimal PEEP being significantly different between the positions (p < 0.01). Moderate positive correlation has been found between TauE vs CRS at all PEEP levels (r2 = 0.43, p < 0.001). CONCLUSIONS: TauE may be a novel method to assess PEEP levels. There was wide variation in patient responses to PEEP, which indicates the need for personalized evaluation.


Subject(s)
COVID-19 , Respiratory Distress Syndrome , Adult , Humans , Positive-Pressure Respiration/methods , Respiration, Artificial/methods , Respiratory Distress Syndrome/therapy , Prospective Studies , Feasibility Studies , COVID-19/therapy
6.
J Int Med Res ; 50(5): 3000605221101970, 2022 May.
Article in English | MEDLINE | ID: mdl-35634917

ABSTRACT

OBJECTIVE: We evaluated pressure-controlled ventilation (PCV) with multiple programmed levels of positive end expiratory pressure (programmed multi-level ventilation; PMLV) in patients with coronavirus disease 2019 (COVID-19)-related acute respiratory distress syndrome (ARDS). METHODS: We conducted a multicenter, retrospective study from November 2020 to February 2021. PMLV was used with PCV in all patients with intensive care admission until improvement in oxygenation (fraction of inspired oxygen [FiO2] ≤0.50 and oxygen saturation [SpO2] >92%). The observed outcomes were improvement of hypoxemia, length of mechanical ventilation, partial pressure of carbon dioxide (PaCO2) stability, and adverse events. RESULTS: Of 188 mechanically ventilated patients with COVID-19-related ARDS, we analyzed 60 patients treated with PMLV. Hypoxemia improved in 55 (92%) patients, as measured by the change in partial pressure of oxygen/FiO2 and SpO2/FiO2 ratios on day 3 versus day 1, and in 32 (66%) ventilated patients on day 7 versus day 3. The median (interquartile range) length of mechanical ventilation for survivors and non-survivors was 8.4 (4.7-14.9) and 6.7 (3.6-10.3) days, respectively. CONCLUSIONS: PMLV appears to be a safe and effective ventilation strategy for improving hypoxemia in patients with COVID-19-related ARDS. Further studies are needed comparing the PMLV mode with the conventional ARDS ventilatory approach.


Subject(s)
COVID-19 , Respiratory Distress Syndrome , COVID-19/complications , COVID-19/therapy , Humans , Hypoxia/etiology , Hypoxia/therapy , Oxygen , Respiratory Distress Syndrome/etiology , Respiratory Distress Syndrome/therapy , Retrospective Studies
8.
Sensors (Basel) ; 22(2)2022 Jan 09.
Article in English | MEDLINE | ID: mdl-35062441

ABSTRACT

Tracking the trajectory of the load carried by the rotary crane is an important problem that allows reducing the possibility of its damage by hitting an obstacle in its working area. On the basis of the trajectory, it is also possible to determine an appropriate control system that would allow for the safe transport of the load. This work concerns research on the load motion carried by a rotary crane. For this purpose, the laboratory crane model was designed in Solidworks software, and numerical simulations were made using the Motion module. The developed laboratory model is a scaled equivalent of the real Liebherr LTM 1020 object. The crane control included two movements: changing the inclination angle of the crane's boom and rotation of the jib with the platform. On the basis of the developed model, a test stand was built, which allowed for the verification of numerical results. Event visualization and trajectory tracking were made using a dynamic vision sensor (DVS) and the Tracker program. Based on the obtained experimental results, the developed numerical model was verified. The proposed trajectory tracking method can be used to develop a control system to prevent collisions during the crane's duty cycle.


Subject(s)
Movement , Software , Motion
9.
Acute Crit Care ; 37(3): 470-473, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35081707

ABSTRACT

We report a patient with severe coronavirus disease 2019 (COVID-19) acute respiratory distress syndrome (ARDS) treated with veno-venous extracorporeal membrane oxygenation (VV ECMO) and programmed multi-level ventilation (PMLV). VV ECMO as a treatment modality for severe ARDS has been described multiple times as a rescue therapy for refractory hypoxemia. It is well known that conventional ventilation can cause ventilator-induced lung injury. Protective ventilation during VV ECMO seems to be beneficial, translating to using low tidal volumes, prone positioning with general concept of open lung approach. However, mechanical ventilation is still required as ECMO per se is usually not sufficient to maintain adequate gas exchange due to hyperdynamic state of the patient and limitation of blood flow via VV ECMO. This report describes ventilation strategy using PMLV during "resting" period of the lung. In short, PMLV is a strategy for ventilating non-homogenous lungs that incorporates expiratory time constants and multiple levels of positive end-expiratory pressure. Using this approach, most affected acute lung injury/ARDS areas can be recruited, while preventing overdistension in healthy areas. To our knowledge, case report using such ventilation strategy for lung resting period has not been previously published.

10.
Med Devices (Auckl) ; 14: 277-285, 2021.
Article in English | MEDLINE | ID: mdl-34584466

ABSTRACT

Mechanical ventilation (MV) has been an integral method used in ICU care for decades. MV is typically viewed as a life-supporting intervention. However, it can also contribute to lung injury through stress and strain, as evidenced by ventilator-induced lung injury (VILI), even in previously healthy lungs. The negative impact may be worsened when significant lung non-homogeneity is present, eg. ALI and ARDS. Protective lung strategies to minimize VILI are to use low tidal volumes (Vt 4-6 mL/kg/PBW), plateau pressures (Pplat) <30 cmH2O and relatively high positive end-expiratory pressures (PEEP). Yet, use of constantly high PEEP levels is well recognized to result in hemodynamic compromise of the right ventricle, increased stress and strain through high mechanical energy impact on the lung and overdistension of relatively healthy lung tissue. Taking these issues into consideration, a different approach to mechanical ventilation was developed specifically for patients with non-homogeneity. This review focuses on a feature called programmed multi-level ventilation (PMLV). It is not a ventilation mode per se, but rather a form of extension that adjusts and modifies any ventilation mode (eg PCV,PSV, VCV, SIMV, etc.). PMLV is based on measured time constants (Tau) of the whole respiratory system, including artificial airways, breathing circuits, humidification devices and mechanical ventilator. Using a physiology-based approach presents a method to ventilate non-homogenous lungs through cyclic changes of different PEEP levels; recruitment takes place in lung areas with long time constants but protects relatively healthy lung areas from overdistension thus minimizing excessive mechanical power to the lung tissue.

11.
J Surg Res ; 159(1): e25-8, 2010 Mar.
Article in English | MEDLINE | ID: mdl-19592035

ABSTRACT

BACKGROUND: In cases of acute surgery or trauma, the most effective method of increasing the level of estrogen in postmenopausal women is its administration immediately pre- or postsurgery. However, in our previous study (J Surg Res 2008; 147:117-122) we showed that postsurgical administration of nonspecific estrogen receptor (ER) agonist decreases wound tensile strength. Therefore, the aim of this study was to evaluate whether this effect is mediated via the alpha or beta ER. MATERIALS AND METHODS: Three months prior to the wound healing experiment, 18 rats were anesthetized and underwent ovariectomy (OVX), while another six rats were sham operated. Two parallel full thickness skin incisions were performed on the back of each rat. Doses of 1mg/kg of either PPT (ER-alpha agonist) or DPN (ER-beta agonist) were administered to 12 OVX rats for 6 d postoperatively, whereas all other animals received vehicle. After 6 d, all animals were sacrificed and samples removed for wound tensile strength measurement and histologic evaluation. RESULTS: The mean wound tensile strength of PPT-treated rats (6.8+/-1.9 g/mm2) was significantly lower compared with all other groups (P<0.05). No significant differences were observed between DPN-treated (8.9+/-2.2 g/mm2), non-OVX vehicle-treated (8.7+/-2.0 g/mm2), and OVX vehicle-treated (9.1+/-1.7 g/mm2) rats. Nevertheless, no remarkable differences were found between groups during histologic evaluation. CONCLUSION: Our results indicate that the wound tensile strength decrease is mediated through the alpha rather than beta ER.


Subject(s)
Estrogen Receptor alpha/agonists , Estrogen Receptor beta/agonists , Estrogen Replacement Therapy , Tensile Strength/drug effects , Wound Healing/drug effects , Animals , Female , Nitriles/pharmacology , Ovariectomy , Phenols/pharmacology , Pyrazoles/pharmacology , Random Allocation , Rats , Rats, Sprague-Dawley , Skin/injuries , Skin/pathology
12.
Lasers Med Sci ; 24(4): 539-47, 2009 Jul.
Article in English | MEDLINE | ID: mdl-18716824

ABSTRACT

Optimal parameters of low-level laser therapy (LLLT) for wound healing are still discussed. Hence, our study was aimed to compare effects of different power densities of LLLT at 635 nm in rats. Four, round, full-thickness, skin wounds were made on the backs of 48 rats that were divided into two groups (non-steroid laser-treated and steroid laser-treated). Three wounds were stimulated daily with a diode laser (daily dose 5 J/cm(2)) each with different power density (1 mW/cm(2), 5 mW/cm(2), and 15 mW/cm(2)), whereas the fourth wound served as a control. Two days, 6 days, and 14 days after surgery, eight animals from each group were killed and samples were removed for histological evaluation. In the non-steroid laser-treated rats, significant acceleration of epithelization and collagen synthesis 2 days and 6 days after surgery was observed in stimulated wounds. In steroid laser-treated rats, 2 days and 14 days after surgery, a decreased leucocyte/macrophage ratio and a reduction in the area of granulation tissue were recorded, respectively. In conclusion, LLLT, by the method we used, improved wound healing in the non-steroid laser-treated rats, but it was useless after corticosteroid treatment.


Subject(s)
Lasers, Semiconductor/therapeutic use , Low-Level Light Therapy/methods , Methylprednisolone/therapeutic use , Skin/injuries , Wound Healing/drug effects , Wound Healing/radiation effects , Animals , Glucocorticoids/therapeutic use , Granulation Tissue/pathology , Leukocytes/pathology , Macrophages/pathology , Male , Rats , Rats, Sprague-Dawley , Skin/drug effects , Skin/pathology , Skin/radiation effects , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...