Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 102
Filter
1.
Gastrointest Endosc ; 99(5): 864, 2024 May.
Article in English | MEDLINE | ID: mdl-38649230
2.
Am J Gastroenterol ; 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38235741

ABSTRACT

INTRODUCTION: Adenoma per colonoscopy (APC) has recently been proposed as a quality measure for colonoscopy. We evaluated the impact of a novel artificial intelligence (AI) system, compared with standard high-definition colonoscopy, for APC measurement. METHODS: This was a US-based, multicenter, prospective randomized trial examining a novel AI detection system (EW10-EC02) that enables a real-time colorectal polyp detection enabled with the colonoscope (CAD-EYE). Eligible average-risk subjects (45 years or older) undergoing screening or surveillance colonoscopy were randomized to undergo either CAD-EYE-assisted colonoscopy (CAC) or conventional colonoscopy (CC). Modified intention-to-treat analysis was performed for all patients who completed colonoscopy with the primary outcome of APC. Secondary outcomes included positive predictive value (total number of adenomas divided by total polyps removed) and adenoma detection rate. RESULTS: In modified intention-to-treat analysis, of 1,031 subjects (age: 59.1 ± 9.8 years; 49.9% male), 510 underwent CAC vs 523 underwent CC with no significant differences in age, gender, ethnicity, or colonoscopy indication between the 2 groups. CAC led to a significantly higher APC compared with CC: 0.99 ± 1.6 vs 0.85 ± 1.5, P = 0.02, incidence rate ratio 1.17 (1.03-1.33, P = 0.02) with no significant difference in the withdrawal time: 11.28 ± 4.59 minutes vs 10.8 ± 4.81 minutes; P = 0.11 between the 2 groups. Difference in positive predictive value of a polyp being an adenoma among CAC and CC was less than 10% threshold established: 48.6% vs 54%, 95% CI -9.56% to -1.48%. There were no significant differences in adenoma detection rate (46.9% vs 42.8%), advanced adenoma (6.5% vs 6.3%), sessile serrated lesion detection rate (12.9% vs 10.1%), and polyp detection rate (63.9% vs 59.3%) between the 2 groups. There was a higher polyp per colonoscopy with CAC compared with CC: 1.68 ± 2.1 vs 1.33 ± 1.8 (incidence rate ratio 1.27; 1.15-1.4; P < 0.01). DISCUSSION: Use of a novel AI detection system showed to a significantly higher number of adenomas per colonoscopy compared with conventional high-definition colonoscopy without any increase in colonoscopy withdrawal time, thus supporting the use of AI-assisted colonoscopy to improve colonoscopy quality ( ClinicalTrials.gov NCT04979962).

3.
Gastrointest Endosc ; 99(3): 326-336.e6, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38065513

ABSTRACT

BACKGROUND AND AIMS: Despite advances in EMR techniques, a high polyp recurrence rate remains a challenge. Due to the scarcity of direct comparisons, we performed an indirect comparison of conventional EMR (EMR alone), underwater EMR (U-EMR), and EMR + adjuvant thermal ablation of polypectomy margins to assess polyp recurrence rates. METHODS: Electronic databases were searched from inception to January 12, 2023, for studies reporting polyp recurrence rates after EMR for large nonpedunculated polyps (>15 mm) with or without adjuvant techniques (snare tip soft coagulation [STSC]/argon plasma coagulation [APC]). An indirect comparison was performed by using the frequentist method. The p-score was calculated to identify preferred intervention. Publication bias was assessed by using a comparison-adjusted funnel plot. RESULTS: A total of 9 full articles were identified. On direct comparisons, EMR + STSC had 82% reduced odds (odds ratio, .18; 95% confidence interval, .13-.26; P < .001), whereas U-EMR alone had 77% reduced odds (odds ratio, .23; 95% confidence interval, .08-.67; P = .007) of polyp recurrence compared with EMR alone. On indirect comparison, all interventions had significantly lower odds of polyp recurrence compared with EMR alone. The p-score ranking showed that EMR + STSC seems a potential first method in reducing the odds of polyp recurrence, followed by U-EMR, EMR + APC, and EMR alone. CONCLUSIONS: EMR + STSC seems to provide favorable odds for reducing polyp recurrence postresection for large nonpedunculated polyps. Standardization of methods to detect residual polyp and prevent polyp recurrence at the time of EMR are required.


Subject(s)
Colonic Polyps , Colorectal Neoplasms , Endoscopic Mucosal Resection , Humans , Colonic Polyps/surgery , Colonoscopy/methods , Endoscopic Mucosal Resection/methods , Colorectal Neoplasms/surgery
4.
Dig Endosc ; 36(4): 406-420, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37723605

ABSTRACT

OBJECTIVES: The health-care sector contributes 4.6% of global greenhouse gas emissions, with gastroenterology playing a significant role due to the widespread use of gastrointestinal (GI) endoscopy. In this review, we aim to understand the carbon footprint in gastroenterology practice associated with GI endoscopy, conferences and recruitment, identify barriers to change, and recommend mitigating strategies. METHODS: A comprehensive search of PubMed, Embase, and the Cochrane Library was conducted to explore the carbon footprint in gastroenterology practice, focusing on endoscopy, inpatient and outpatient settings, and recruitment practices. Recommendations for mitigating the carbon footprint were derived. RESULTS: This narrative review analyzed 34 articles on the carbon footprint in gastroenterology practice. Carbon footprint of endoscopy in the United States is approximately 85,768 metric tons of CO2 emission annually, equivalent to 9 million gallons of gasoline consumed, or 94 million pounds of coal burned. Each endoscopy generates 2.1 kg of disposable waste (46 L volume), of which 64% of waste goes to the landfill, 28% represents biohazard waste, and 9% is recycled. The per-case manufacturing carbon footprint for single-use devices and reusable devices is 1.37 kg CO2 and 0.0017 kg CO2, respectively. Inpatient and outpatient services contributed through unnecessary procedures, prolonged hospital stays, and excessive use of single-use items. Fellowship recruitment and gastrointestinal conferences added to the footprint, mainly due to air travel and hotel stays. CONCLUSION: Gastrointestinal endoscopy and practice contribute to the carbon footprint through the use of disposables such as single-use endoscopes and waste generation. To achieve environmental sustainability, measures such as promoting reusable endoscopy equipment over single-use endoscopes, calculating institutional carbon footprints, establishing benchmarking standards, and embracing virtual platforms such as telemedicine and research meetings should be implemented.


Subject(s)
Carbon Dioxide , Gastroenterology , United States , Humans , Carbon Dioxide/analysis , Goals , Carbon Footprint
5.
Gastroenterology ; 166(3): 496-502.e3, 2024 03.
Article in English | MEDLINE | ID: mdl-38123023

ABSTRACT

BACKGROUND & AIMS: Gastrointestinal (GI) endoscopy procedures are critical for screening, diagnosis, and treatment of a variety of GI disorders. However, like the procedures in other medical disciplines, they are a source of environmental waste generation and energy consumption. METHODS: We prospectively collected data on total waste generation, energy consumption, and the role of intraprocedural inventory audit of a single tertiary care academic endoscopy unit over a 2-month period (May-June 2022). Detailed data on items used were collected, including procedure type (esophagogastroduodenoscopy or colonoscopy), accessories, intravenous tubing, biopsy jars, linen, and personal protective equipment use. Data on endoscope reprocessing-related waste generation and energy use in the endoscopy unit (equipment, lights, and computers) were also collected. We used an endoscopy staff-guided auditing and review of the items used during procedures to determine potentially recyclable items going to landfill waste. The waste generated was stratified into biohazardous, nonbiohazardous, or potentially recyclable items. RESULTS: A total of 450 consecutive procedures were analyzed for total waste management (generation and reprocessing) and energy consumption. The total waste generated during the study period was 1398.6 kg (61.6% directly going to landfill, 33.3% biohazard waste, and 5.1% sharps), averaging 3.03 kg/procedure. The average waste directly going to landfill was 219 kg per 100 procedures. The estimated total annual waste generation approximated the size of 2 football fields (1-foot-high layered waste). Endoscope reprocessing generated 194 gallons of liquid waste per day, averaging 13.85 gallons per procedure. Total energy consumption in the endoscopy unit was 277.1 kW·h energy per day; for every 100 procedures, amounting to 1200 miles of distance traveled by an average fuel efficiency car. The estimated carbon footprint for every 100 GI procedures was 1501 kg carbon dioxide (CO2) equivalent (= 1680 lbs of coal burned), which would require 1.8 acres of forests to sequester. The recyclable waste audit and review demonstrated that 20% of total waste consisted of potentially recyclable items (8.6 kg/d) that could be avoided by appropriate waste segregation of these items. CONCLUSIONS: On average, every 100 GI endoscopy procedures (esophagogastroduodenoscopy/colonoscopy) are associated with 303 kg of solid waste and 1385 gallons of liquid waste generation, and 1980 kW·h energy consumption. Potentially recyclable materials account for 20% of the total waste. These data could serve as an actionable model for health systems to reduce total waste generation and decrease landfill waste and water waste toward environmentally sustainable endoscopy units.


Subject(s)
Waste Management , Humans , Prospective Studies , Waste Management/methods , Waste Disposal Facilities , Endoscopy, Gastrointestinal/adverse effects , Carbon Footprint
6.
Gastroenterol Hepatol (N Y) ; 19(3): 165-168, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37706107
7.
Gastrointest Endosc ; 98(3): 285-305.e38, 2023 09.
Article in English | MEDLINE | ID: mdl-37498265

ABSTRACT

This document from the American Society for Gastrointestinal Endoscopy (ASGE) provides a full description of the methodology used in the review of the evidence used to inform the final guidance outlined in the accompanying Summary and Recommendations document regarding the role of endoscopic submucosal dissection (ESD) in the management of early esophageal and gastric cancers. This guideline used the Grading of Recommendations, Assessment, Development and Evaluation framework and specifically addresses the role of ESD versus EMR and/or surgery, where applicable, for the management of early esophageal squamous cell carcinoma (ESCC), esophageal adenocarcinoma (EAC), and gastric adenocarcinoma (GAC) and their corresponding precursor lesions. For ESCC, the ASGE suggests ESD over EMR for patients with early-stage, well-differentiated, nonulcerated cancer >15 mm, whereas in patients with similar lesions ≤15 mm, the ASGE suggests either ESD or EMR. The ASGE suggests against surgery for such patients with ESCC, whenever possible. For EAC, the ASGE suggests ESD over EMR for patients with early-stage, well-differentiated, nonulcerated cancer >20 mm, whereas in patients with similar lesions measuring ≤20 mm, the ASGE suggests either ESD or EMR. For GAC, the ASGE suggests ESD over EMR for patients with early-stage, well or moderately differentiated, nonulcerated intestinal type cancer measuring 20 to 30 mm, whereas for patients with similar lesions <20 mm, the ASGE suggests either ESD or EMR. The ASGE suggests against surgery for patients with such lesions measuring ≤30 mm, whereas for lesions that are poorly differentiated, regardless of size, the ASGE suggests surgical evaluation over endosic approaches.


Subject(s)
Adenocarcinoma , Endoscopic Mucosal Resection , Esophageal Neoplasms , Esophageal Squamous Cell Carcinoma , Stomach Neoplasms , Humans , Adenocarcinoma/surgery , Adenocarcinoma/pathology , Endoscopic Mucosal Resection/methods , Endoscopy, Gastrointestinal/methods , Esophageal Neoplasms/surgery , Esophageal Neoplasms/pathology , Retrospective Studies , Stomach Neoplasms/surgery , Stomach Neoplasms/pathology , Treatment Outcome
8.
Gastrointest Endosc ; 98(3): 271-284, 2023 09.
Article in English | MEDLINE | ID: mdl-37498266

ABSTRACT

This clinical practice guideline from the American Society for Gastrointestinal Endoscopy (ASGE) provides an evidence-based summary and recommendations regarding the role of endoscopic submucosal dissection (ESD) in the management of early esophageal and gastric cancers. It is accompanied by the document subtitled "Methodology and Review of Evidence," which provides a detailed account of the methodology used for the evidence review. This guideline was developed using the Grading of Recommendations, Assessment, Development and Evaluation framework and specifically addresses the role of ESD versus EMR and/or surgery, where applicable, for the management of early esophageal squamous cell carcinoma (ESCC), esophageal adenocarcinoma (EAC), and gastric adenocarcinoma (GAC) and their corresponding precursor lesions. For ESCC, the ASGE suggests ESD over EMR for patients with early-stage, well-differentiated, nonulcerated cancer >15 mm, whereas in patients with similar lesions ≤15 mm, the ASGE suggests either ESD or EMR. The ASGE suggests against surgery for such patients with ESCC, whenever possible. For EAC, the ASGE suggests ESD over EMR for patients with early-stage, well-differentiated, nonulcerated cancer >20 mm, whereas in patients with similar lesions measuring ≤20 mm, the ASGE suggests either ESD or EMR. For GAC, the ASGE suggests ESD over EMR for patients with early-stage, well- or moderately differentiated, nonulcerated intestinal type cancer measuring 20 to 30 mm, whereas for patients with similar lesions <20 mm, the ASGE suggests either ESD or EMR. The ASGE suggests against surgery for patients with such lesions measuring ≤30 mm, whereas for lesions that are poorly differentiated, regardless of size, we suggest surgical evaluation over endoscopic approaches.


Subject(s)
Adenocarcinoma , Endoscopic Mucosal Resection , Esophageal Neoplasms , Esophageal Squamous Cell Carcinoma , Stomach Neoplasms , Humans , Esophageal Neoplasms/surgery , Esophageal Neoplasms/pathology , Stomach Neoplasms/surgery , Stomach Neoplasms/pathology , Endoscopic Mucosal Resection/methods , Endoscopy, Gastrointestinal , Adenocarcinoma/surgery , Adenocarcinoma/pathology , Treatment Outcome , Retrospective Studies
9.
Gastrointest Endosc ; 98(5): 685-693, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37307900

ABSTRACT

This clinical practice guideline from the American Society for Gastrointestinal Endoscopy provides an evidence-based approach for the diagnosis of malignancy in patients with biliary strictures of undetermined etiology. This document was developed using the Grading of Recommendations Assessment, Development and Evaluation framework and addresses the role of fluoroscopic-guided biopsy sampling, brush cytology, cholangioscopy, and EUS in the diagnosis of malignancy in patients with biliary strictures. In the endoscopic workup of these patients, we suggest the use of fluoroscopic-guided biopsy sampling in addition to brush cytology over brush cytology alone, especially for hilar strictures. We suggest the use of cholangioscopic and EUS-guided biopsy sampling especially for patients who undergo nondiagnostic sampling, cholangioscopic biopsy sampling for nondistal strictures and EUS-guided biopsy sampling distal strictures or those with suspected spread to surrounding lymph nodes and other structures.

10.
Gastrointest Endosc ; 98(5): 694-712.e8, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37307901

ABSTRACT

Biliary strictures of undetermined etiology pose a diagnostic challenge for endoscopists. Despite advances in technology, diagnosing malignancy in biliary strictures often requires multiple procedures. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework was used to rigorously review and synthesize the available literature on strategies used to diagnose undetermined biliary strictures. Using a systematic review and meta-analysis of each diagnostic modality, including fluoroscopic-guided biopsy sampling, brush cytology, cholangioscopy, and EUS-guided FNA or fine-needle biopsy sampling, the American Society for Gastrointestinal Endoscopy Standards of Practice Committee provides this guideline on modalities used to diagnose biliary strictures of undetermined etiology. This document summarizes the methods used in the GRADE analysis to make recommendations, whereas the accompanying article subtitled "Summary and Recommendations" contains a concise summary of our findings and final recommendations.

11.
Gastrointest. endosc ; 98(5): 694-712, 20230610. tab
Article in English | BIGG - GRADE guidelines | ID: biblio-1524147

ABSTRACT

Biliary strictures of undetermined etiology pose a diagnostic challenge for endoscopists. Despite advances in technology, diagnosing malignancy in biliary strictures often requires multiple procedures. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework was used to rigorously review and synthesize the available literature on strategies used to diagnose undetermined biliary strictures. Using a systematic review and meta-analysis of each diagnostic modality, including fluoroscopic-guided biopsy sampling, brush cytology, cholangioscopy, and EUS-guided FNA or fine-needle biopsy sampling, the American Society for Gastrointestinal Endoscopy Standards of Practice Committee provides this guideline on modalities used to diagnose biliary strictures of undetermined etiology. This document summarizes the methods used in the GRADE analysis to make recommendations, whereas the accompanying article subtitled "Summary and Recommendations" contains a concise summary of our findings and final recommendations.


Subject(s)
Bile Duct Diseases/diagnostic imaging , Evidence-Based Medicine , Bile Duct Diseases/etiology , Biopsy , Endoscopy
12.
Gastrointest Endosc ; 98(4): 482-491, 2023 10.
Article in English | MEDLINE | ID: mdl-37245720

ABSTRACT

This clinical practice guideline from the American Society for Gastrointestinal Endoscopy provides an evidence-based approach to strategies to prevent endoscopy-related injury (ERI) in GI endoscopists. It is accompanied by the article subtitled "Methodology and Review of Evidence," which provides a detailed account of the methodology used for the evidence review. This document was developed using the Grading of Recommendations Assessment, Development and Evaluation framework. The guideline estimates the rates, sites, and predictors of ERI. Additionally, it addresses the role of ergonomics training, microbreaks and macrobreaks, monitor and table positions, antifatigue mats, and use of ancillary devices in decreasing the risk of ERI. We recommend formal ergonomics education and neutral posture during the performance of endoscopy, achieved through adjustable monitor and optimal procedure table position, to reduce the risk of ERI. We suggest taking microbreaks and scheduled macrobreaks and using antifatigue mats during procedures to prevent ERI. We suggest the use of ancillary devices in those with risk factors predisposing them to ERI.


Subject(s)
Endoscopy, Gastrointestinal , Ergonomics , Humans , Posture , Risk Factors
15.
Gastrointest Endosc ; 98(2): 155-161.e1, 2023 08.
Article in English | MEDLINE | ID: mdl-36914140

ABSTRACT

BACKGROUND AND AIMS: Real-world data on the adverse events and the survival benefit of Barrett's endoscopic therapy (BET) are limited. The aim of this study was to examine the safety and effectiveness (survival benefit) of BET in patients with neoplastic Barrett's esophagus (BE). METHODS: An electronic health record-based database (TriNetX) was used to select patients with BE with dysplasia and esophageal adenocarcinoma (EAC) from 2016 to 2020. Primary outcome was 3-year mortality among patients with high-grade dysplasia (HGD) or EAC who underwent BET versus 2 comparison cohorts: patients with HGD or EAC who had not undergone BET and patients with GERD but no BE/EAC. Secondary outcome was adverse events (esophageal perforation, upper GI bleeding, chest pain, and esophageal stricture) after BET. To control for confounding variables, 1:1 propensity score matching was performed. RESULTS: We identified 27,556 patients with BE and dysplasia, of whom 5295 underwent BET. After propensity score matching, patients with HGD and EAC who underwent BET had significantly lower 3-year mortality (HGD risk ratio [RR], .59; 95% CI, .49-.71; EAC RR, .53; 95% CI, .44-.65) compared with corresponding cohorts who did not undergo BET (P < .001). There was no difference in median 3-year mortality between control subjects (GERD without BE/EAC) compared with patients with HGD (RR, 1.04; 95% CI, .84-1.27) who underwent BET. Finally, there was no difference in median 3-year mortality between patients who underwent BET compared with patients who underwent esophagectomy among both HGD (RR, .67; 95% CI, .39-1.14; P =.14) and EAC (RR, .73; 95% CI, .47-1.13; P = .14). Esophageal stricture was the most common adverse event (6.5%) after BET. CONCLUSIONS: Real-world, population-based evidence from this large database shows that endoscopic therapy is safe and effective for patients with BE. Endoscopic therapy is associated with a significantly lower 3-year mortality; however, it leads to esophageal strictures in 6.5% of treated patients.


Subject(s)
Barrett Esophagus , Esophageal Neoplasms , Esophageal Stenosis , Gastroesophageal Reflux , Precancerous Conditions , Humans , Esophageal Stenosis/complications , Esophageal Neoplasms/pathology , Barrett Esophagus/pathology , Esophagoscopy , Gastroesophageal Reflux/complications , Precancerous Conditions/pathology , Disease Progression
16.
Gastrointest Endosc ; 97(4): 615-637.e11, 2023 04.
Article in English | MEDLINE | ID: mdl-36792483

ABSTRACT

This clinical practice guideline from the American Society for Gastrointestinal Endoscopy provides an evidence-based approach for strategies to manage biliary strictures in liver transplant recipients. This document was developed using the Grading of Recommendations Assessment, Development and Evaluation framework. The guideline addresses the role of ERCP versus percutaneous transhepatic biliary drainage and covered self-expandable metal stents (cSEMSs) versus multiple plastic stents for therapy of strictures, use of MRCP for diagnosing post-transplant biliary strictures, and administration of antibiotics versus no antibiotics during ERCP. In patients with post-transplant biliary strictures, we suggest ERCP as the initial intervention and cSEMSs as the preferred stent. In patients with unclear diagnosis or intermediate probability of a stricture, we suggest MRCP as the diagnostic modality. We suggest that antibiotics should be administered during ERCP when biliary drainage cannot be assured.


Subject(s)
Cholestasis , Liver Transplantation , Humans , Constriction, Pathologic/etiology , Constriction, Pathologic/therapy , Cholangiopancreatography, Endoscopic Retrograde/methods , Liver Transplantation/adverse effects , Cholestasis/etiology , Cholestasis/surgery , Stents , Endoscopy, Gastrointestinal
17.
Gastrointest Endosc ; 97(4): 607-614, 2023 04.
Article in English | MEDLINE | ID: mdl-36797162

ABSTRACT

This clinical practice guideline from the American Society for Gastrointestinal Endoscopy provides an evidence-based approach for strategies to manage biliary strictures in liver transplant recipients. This document was developed using the Grading of Recommendations Assessment, Development and Evaluation framework. The guideline addresses the role of ERCP versus percutaneous transhepatic biliary drainage and covered self-expandable metal stents (cSEMSs) versus multiple plastic stents for therapy of post-transplant strictures, use of MRCP for diagnosing post-transplant biliary strictures, and administration of antibiotics versus no antibiotics during ERCP. In patients with post-transplant biliary strictures, we suggest ERCP as the initial intervention and cSEMSs as the preferred stent for extrahepatic strictures. In patients with unclear diagnoses or intermediate probability of a stricture, we suggest MRCP as the diagnostic modality. We suggest that antibiotics should be administered during ERCP when biliary drainage cannot be ensured.


Subject(s)
Cholestasis , Liver Transplantation , Humans , United States , Constriction, Pathologic/etiology , Constriction, Pathologic/therapy , Cholangiopancreatography, Endoscopic Retrograde , Liver Transplantation/adverse effects , Cholestasis/etiology , Cholestasis/surgery , Stents , Endoscopy, Gastrointestinal
18.
Dig Dis Sci ; 68(3): 852-859, 2023 03.
Article in English | MEDLINE | ID: mdl-35708794

ABSTRACT

BACKGROUND AND AIMS: A subset of patients needing long-term enteral access are unable to undergo a conventional transoral "pull" percutaneous endoscopic gastrostomy (PEG). We assessed the safety and efficacy of an introducer-style endoscopic direct PEG (DPEG) and an interventional radiologist guided gastrostomy (IRG) among patients unable to undergo a pull PEG. METHODS: In this single center, non-randomized, pilot study, patients unable to undergo a transoral Pull PEG were prospectively recruited for a DPEG during the index endoscopy. IRG procedures performed at our center served as the comparison group. The primary outcome was technical success and secondary outcomes included 30-day and 90-day all-cause mortality, procedure duration, dosage of medications, adverse events, and 30-day all-cause hospitalization. The Charlson comorbidity index was used to compare comorbidities. RESULTS: A total of 47 patients (68.3 ± 7.13 years) underwent DPEG and 45 patients (68.6 ± 8.23 years) underwent IRG. The respective Charlson comorbidity scores were 6.37 ± 2 and 6.16 ± 1.72 (P = 0.59). Malignancies of the upper aerodigestive tract were the most common indications for DPEG and IRG (42 vs. 37; P = 0.38). The outcomes for DPEG and IRG were as follows: technical success: 96 vs. 98%; P = 1; 30-day all-cause mortality: 0 vs 15%, P < 0.01; 90-day all-cause mortality: 0 vs. 31%, P < 0.001; 30-day hospitalization: 19 vs. 38%; P = 0.06; procedure duration: 23.8 ± 1.39 vs. 29.5 ± 2.03 min, P = 0.02; midazolam dose: 4.5 ± 1.6 vs. 1.23 ± 0.6 mg; P < 0.001, and opiate dose: 105.6 ± 38.2 vs. 70.7 ± 34.5 µg, P < 0.001, respectively. Perforation of the colon during IRG was the sole serious adverse event. CONCLUSION: DPEG is a safe and effective alternative to IRG in patients unable to undergo a conventional transoral pull PEG and may be considered as a primary modality for enteral support. CLINICALTRIALS: gov Identifier: NCT04151030.


Subject(s)
Gastrostomy , Surgical Stomas , Humans , Gastrostomy/adverse effects , Gastrostomy/methods , Pilot Projects , Endoscopy, Gastrointestinal/adverse effects , Radiography , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...