Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 95
Filter
1.
AJNR Am J Neuroradiol ; 42(6): 1080-1086, 2021 06.
Article in English | MEDLINE | ID: mdl-33737270

ABSTRACT

BACKGROUND AND PURPOSE: Despite high interest in machine-learning algorithms for automated segmentation of MRIs of patients with brain tumors, there are few reports on the variability of segmentation results. The purpose of this study was to obtain benchmark measures of repeatability for a widely accessible software program, BraTumIA (Versions 1.2 and 2.0), which uses a machine-learning algorithm to segment tumor features on contrast-enhanced brain MR imaging. MATERIALS AND METHODS: Automatic segmentation of enhancing tumor, tumor edema, nonenhancing tumor, and necrosis was performed on repeat MR imaging scans obtained approximately 2 days apart in 20 patients with recurrent glioblastoma. Measures of repeatability and spatial overlap, including repeatability and Dice coefficients, are reported. RESULTS: Larger volumes of enhancing tumor were obtained on later compared with earlier scans (mean, 26.3 versus 24.2 mL for BraTumIA 1.2; P < .05; and 24.9 versus 22.9 mL for BraTumIA 2.0, P < .01). In terms of percentage change, repeatability coefficients ranged from 31% to 46% for enhancing tumor and edema components and from 87% to 116% for nonenhancing tumor and necrosis. Dice coefficients were highest (>0.7) for enhancing tumor and edema components, intermediate for necrosis, and lowest for nonenhancing tumor and did not differ between software versions. Enhancing tumor and tumor edema were smaller, and necrotic tumor larger using BraTumIA 2.0 rather than 1.2. CONCLUSIONS: Repeatability and overlap metrics varied by segmentation type, with better performance for segmentations of enhancing tumor and tumor edema compared with other components. Incomplete washout of gadolinium contrast agents could account for increasing enhancing tumor volumes on later scans.


Subject(s)
Brain Neoplasms , Glioblastoma , Algorithms , Brain Neoplasms/diagnostic imaging , Glioblastoma/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Tumor Burden
2.
Surg Endosc ; 34(10): 4702-4711, 2020 10.
Article in English | MEDLINE | ID: mdl-32780240

ABSTRACT

BACKGROUND: The laparoscopic approach to liver resection may reduce morbidity and hospital stay. However, uptake has been slow due to concerns about patient safety and oncological radicality. Image guidance systems may improve patient safety by enabling 3D visualisation of critical intra- and extrahepatic structures. Current systems suffer from non-intuitive visualisation and a complicated setup process. A novel image guidance system (SmartLiver), offering augmented reality visualisation and semi-automatic registration has been developed to address these issues. A clinical feasibility study evaluated the performance and usability of SmartLiver with either manual or semi-automatic registration. METHODS: Intraoperative image guidance data were recorded and analysed in patients undergoing laparoscopic liver resection or cancer staging. Stereoscopic surface reconstruction and iterative closest point matching facilitated semi-automatic registration. The primary endpoint was defined as successful registration as determined by the operating surgeon. Secondary endpoints were system usability as assessed by a surgeon questionnaire and comparison of manual vs. semi-automatic registration accuracy. Since SmartLiver is still in development no attempt was made to evaluate its impact on perioperative outcomes. RESULTS: The primary endpoint was achieved in 16 out of 18 patients. Initially semi-automatic registration failed because the IGS could not distinguish the liver surface from surrounding structures. Implementation of a deep learning algorithm enabled the IGS to overcome this issue and facilitate semi-automatic registration. Mean registration accuracy was 10.9 ± 4.2 mm (manual) vs. 13.9 ± 4.4 mm (semi-automatic) (Mean difference - 3 mm; p = 0.158). Surgeon feedback was positive about IGS handling and improved intraoperative orientation but also highlighted the need for a simpler setup process and better integration with laparoscopic ultrasound. CONCLUSION: The technical feasibility of using SmartLiver intraoperatively has been demonstrated. With further improvements semi-automatic registration may enhance user friendliness and workflow of SmartLiver. Manual and semi-automatic registration accuracy were comparable but evaluation on a larger patient cohort is required to confirm these findings.


Subject(s)
Augmented Reality , Liver/surgery , Surgery, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Feasibility Studies , Female , Humans , Male , Middle Aged
3.
Appl Phys Lett ; 114(11): 113505, 2019 Mar 18.
Article in English | MEDLINE | ID: mdl-30967687

ABSTRACT

Strongly directional ultrasound sources are desirable for many minimally invasive applications, as they enable high-quality imaging in the presence of positioning uncertainty. All-optical ultrasound is an emerging paradigm that exhibits high frequencies, large bandwidths, and a strong miniaturisation potential. Here, we report the design, modelling, and fabrication of a highly directional fibre-optic ultrasound transmitter that uses a composite of reduced graphene oxide and polydimethylsiloxane as the optical ultrasound generator. The ultrasound transmitter, which had an outer diameter of just 630 µm, generated ultrasound with a pressure exceeding 0.4 MPa for axial distances up to 16 mm, at a large bandwidth of 24.3 MHz. The ultrasound beam exhibited low divergence, with a beam diameter ranging between 0.6 and 2.1 mm for distances between 0 and 16 mm. The presented directional optical ultrasound source is hence well-suited to high-resolution interventional imaging.

4.
Opt Express ; 27(4): 5641-5654, 2019 Feb 18.
Article in English | MEDLINE | ID: mdl-30876162

ABSTRACT

We report the development and characterisation of highly miniaturised fibre-optic sensors for simultaneous pressure and temperature measurement, and a compact interrogation system with a high sampling rate. The sensors, which have a maximum diameter of 250 µm, are based on multiple low-finesse optical cavities formed from polydimethylsiloxane (PDMS), positioned at the distal ends of optical fibres, and interrogated using phase-resolved low-coherence interferometry. At acquisition rates of 250 Hz, temperature and pressure changes of 0.0021 °C and 0.22 mmHg are detectable. An in vivo experiment demonstrated that the sensors had sufficient speed and sensitivity for monitoring dynamic physiological pressure waveforms. These sensors are ideally suited to various applications in minimally invasive surgery, where diminutive lateral dimensions, high sensitivity and low manufacturing complexities are particularly valuable.


Subject(s)
Fiber Optic Technology/instrumentation , Interferometry/methods , Pressure , Temperature , Equipment Design , Optical Fibers , Transducers
5.
Opt Lett ; 44(24): 6005-6008, 2019 Dec 15.
Article in English | MEDLINE | ID: mdl-32628218

ABSTRACT

A versatile and scalable fabrication method for laser-generated focused ultrasound transducers is proposed. The method is based on stamping a coated negative mold onto polydimethylsiloxane, and it can be adapted to include different optical absorbers that are directly transferred or synthesized in situ. Transducers with a range of sizes down to 3 mm in diameter are presented, incorporating two carbonaceous (multiwalled carbon nanoparticles and candle soot nanoparticles) and one plasmonic (gold nanoparticles) optically absorbing component. The fabricated transducers operate at central frequencies in the vicinity of 10 MHz with bandwidths in the range of 15-20 MHz. A transducer with a diameter of 5 mm was found to generate a positive peak pressure greater than 35 MPa in the focal zone with a tight focal spot of 150 µm in lateral width. Ultrasound cavitation on the tip of an optical fiber was demonstrated in water for a transducer with a diameter as small as 3 mm.

6.
Phys Educ ; 51(4): 045015, 2016 Jul.
Article in English | MEDLINE | ID: mdl-29249838

ABSTRACT

In this paper we present a system aimed at demonstrating the photoacoustic (PA) effect for educational purposes. PA imaging is a hybrid imaging modality that requires no contrast agent and has a great potential for spine and brain lesion characterisation, breast cancer and blood flow monitoring notably in the context of fetal surgery. It relies on combining light excitation with ultrasound reception. Our brief was to present and explain PA imaging in a public-friendly way suitable for a variety of ages and backgrounds. We developed a simple, accessible demonstration unit using readily available materials. We used a modulated light emitting diode (LED) torch and an electronic stethoscope. The output of a music player was used for light modulation and the chest piece of the stethoscope covered by a black tape was used as an absorbing target and an enclosed chamber. This demonstration unit was presented to the public at the Bloomsbury Festival On Light in October 2015. Our stall was visited by over 100 people of varying ages. Twenty families returned in-depth evaluation questionnaires, which show that our explanations of the photoacoustic effect were well understood. Their interest in biomedical engineering was increased.

7.
Biomed Opt Express ; 4(11): 2619-28, 2013.
Article in English | MEDLINE | ID: mdl-24298420

ABSTRACT

Epidural catheters are used to deliver anesthetics and opioids for managing pain in many clinical scenarios. Currently, epidural catheter insertion is performed without information about the tissues that are directly ahead of the catheter. As a result, the catheter can be incorrectly positioned within a blood vessel, which can cause toxicity. Recent studies have shown that optical reflectance spectroscopy could be beneficial for guiding needles that are used to insert catheters. In this study, we investigate the whether this technique could benefit the placement of catheters within the epidural space. We present a novel optical epidural catheter with integrated polymer light guides that allows for optical spectra to be acquired from tissues at the distal tip. To obtain an initial indication of the information that could be obtained, reflectance values and photon penetration depth were estimated using Monte Carlo simulations, and optical reflectance spectra were acquired during a laminectomy of a swine ex vivo. Large differences between the spectra acquired from epidural adipose tissue and from venous blood were observed. The optical catheter has the potential to provide real-time detection of intravascular catheter placement that could reduce the risk of complications.

8.
Br J Cancer ; 107(9): 1481-7, 2012 Oct 23.
Article in English | MEDLINE | ID: mdl-23037712

ABSTRACT

BACKGROUND: Bevacizumab improves outcome for most recurrent glioblastoma patients, but the duration of benefit is limited and survival after initial bevacizumab progression is poor. We evaluated bevacizumab continuation beyond initial progression among recurrent glioblastoma patients as it is a common, yet unsupported practice in some countries. METHODS: We analysed outcome among all patients (n=99) who received subsequent therapy after progression on one of five consecutive, single-arm, phase II clinical trials evaluating bevacizumab regimens for recurrent glioblastoma. Of note, the five trials contained similar eligibility, treatment and assessment criteria, and achieved comparable outcome. RESULTS: The median overall survival (OS) and OS at 6 months for patients who continued bevacizumab therapy (n=55) were 5.9 months (95% confidence interval (CI): 4.4, 7.6) and 49.2% (95% CI: 35.2, 61.8), compared with 4.0 months (95% CI: 2.1, 5.4) and 29.5% (95% CI: 17.0, 43.2) for patients treated with a non-bevacizumab regimen (n=44; P=0.014). Bevacizumab continuation was an independent predictor of improved OS (hazard ratio=0.64; P=0.04). CONCLUSION: The results of our retrospective pooled analysis suggest that bevacizumab continuation beyond initial progression modestly improves survival compared with available non-bevacizumab therapy for recurrent glioblastoma patients require evaluation in an appropriately randomised, prospective trial.


Subject(s)
Angiogenesis Inhibitors/administration & dosage , Antibodies, Monoclonal, Humanized/administration & dosage , Brain Neoplasms/drug therapy , Glioblastoma/drug therapy , Neoplasm Recurrence, Local/drug therapy , Adult , Aged , Angiogenesis Inhibitors/adverse effects , Antibodies, Monoclonal, Humanized/adverse effects , Bevacizumab , Disease Progression , Drug Administration Schedule , Humans , Middle Aged , Retrospective Studies , Survival Analysis , Treatment Outcome , Young Adult
9.
Article in English | MEDLINE | ID: mdl-22494515

ABSTRACT

The ability of the fungus Fusarium proliferatum to cause kernel black point disease in wheat was previously established, but natural contamination of black point wheat with both F. proliferatum and fumonisin mycotoxins has not been studied in the United States. Low levels of fumonisins were detected in nine of 43 wheat samples with kernel black point disease that were obtained from across the United States. A subset of samples was contaminated with F. proliferatum as well as with F. fujikuroi, F. nygamai, F. thapsinum and F. verticillioides, species closely related to F. proliferatum and morphologically similar to it in that they produce chains of asexual spores, or conidia. Nevertheless, of conidial chain-forming fusaria isolated from symptomatic wheat, F. proliferatum dominated. In greenhouse tests, isolates of F. proliferatum and the other species recovered from wheat samples were able to cause symptoms of kernel black point and, in some cases, low levels of fumonisin contamination of wheat. These data add to the understanding of the risk of fumonisin contamination of wheat and the potential for Fusarium species to cause kernel black point disease and fumonisin contamination of wheat. Further, the results of this study indicate that while US-grown wheat can sporadically be contaminated by fumonisins, the natural contamination levels seem to be low. The observations made provide evidence that fumonisins are not likely to be a factor contributing to the ability of Fusarium to cause kernel black point disease.


Subject(s)
Fumonisins/analysis , Fusarium/isolation & purification , Plant Diseases/microbiology , Triticum/microbiology , Chromatography, Liquid , Mass Spectrometry , United States
10.
Mycoses ; 55(3): e74-84, 2012 May.
Article in English | MEDLINE | ID: mdl-22360318

ABSTRACT

Chronic disseminated candidosis, often referred to as hepatosplenic candidosis (HSC), is an infection due to Candida spp. that mainly involves the liver and spleen. HSC occurs mostly in patients after profound and prolonged neutropenia, which is more often seen in patients with acute haematological malignancies. The incidence of HSC ranges from 3% to 29% in patients suffering from Acute Leukaemia. However, it is now seen less frequently with the widespread use of antifungal agents as prophylaxis or as preemptive therapy. Early and adequate diagnosis and treatment of HSC are crucial, as treatment delays can negatively affect the prognosis of the underlying condition. The pathogenesis is not well understood, but it is believed that it may be due to an unbalanced adaptive immune response that leads to an exacerbated inflammatory reaction, resulting in an Immune Reconstitution Inflammatory Syndrome. In this context, new therapeutic approaches such as the use of adjuvant high-dose corticosteroids have been shown beneficial. This article will focus on the clinical, diagnostic and therapeutic aspects of HSC and provide an accurate review of recent pathophysiological data.


Subject(s)
Candida/physiology , Candidiasis/microbiology , Liver Diseases/microbiology , Splenic Diseases/microbiology , Animals , Antifungal Agents/therapeutic use , Candida/isolation & purification , Candidiasis/drug therapy , Candidiasis/immunology , Humans , Liver Diseases/drug therapy , Liver Diseases/immunology , Splenic Diseases/drug therapy , Splenic Diseases/immunology
11.
Br J Radiol ; 85(1012): 382-9, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21224297

ABSTRACT

OBJECTIVES: The aim of this study was to determine the prognostic significance of changes in parameters derived from diffusion tensor imaging (DTI) that occur in response to treatment with bevacizumab and irinotecan in patients with recurrent glioblastoma multiforme. METHODS: 15 patients with recurrent glioblastoma multiforme underwent serial 1.5 T MRI. Axial single-shot echo planar DTI was obtained on scans performed 3 days and 1 day prior to and 6 weeks after initiation of therapy with bevacizumab and irinotecan. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) maps were registered to whole brain contrast-enhanced three-dimensional (3D) spoiled gradient recalled and 3D fluid attenuation inversion recovery (FLAIR) image volumes. Anatomic image volumes were segmented to isolate regions of interest defined by tumour-related enhancement (TRE) and FLAIR signal abnormality (FSA). Mean ADC and mean FA were calculated for each region. A Bland-Altman repeatability coefficient was also calculated for each parameter based on the two pre-treatment studies. A patient was considered to have a change in FA or ADC after therapy if the difference between the pre- and post-treatment values was greater than the repeatability coefficient for that parameter. Survival was compared using a Cox proportional hazard model. RESULTS: DTI detected a change in ADC within FSA after therapy in nine patients (five in whom ADC was increased; four in whom it was decreased). Patients with a change in ADC within FSA had significantly shorter overall survival (p=0.032) and progression free survival (p=0.046) than those with no change. CONCLUSION: In patients with recurrent glioblastoma multiforme treated with bevacizumab and irinotecan, a change in ADC after therapy in FSA is associated with decreased survival.


Subject(s)
Angiogenesis Inhibitors/therapeutic use , Antibodies, Monoclonal, Humanized/therapeutic use , Diffusion Tensor Imaging , Glioblastoma/drug therapy , Glioblastoma/mortality , Adult , Angiogenesis Inhibitors/administration & dosage , Anisotropy , Antibodies, Monoclonal, Humanized/administration & dosage , Antineoplastic Agents, Phytogenic/administration & dosage , Antineoplastic Agents, Phytogenic/therapeutic use , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Bevacizumab , Camptothecin/administration & dosage , Camptothecin/analogs & derivatives , Camptothecin/therapeutic use , Female , Glioblastoma/diagnosis , Humans , Irinotecan , Kaplan-Meier Estimate , Male , Middle Aged , Neoplasm Recurrence, Local , Prognosis
12.
Clin Neuropathol ; 30(2): 75-9, 2011.
Article in English | MEDLINE | ID: mdl-21329616

ABSTRACT

OBJECTIVE: To report a case of primary intracerebral Hodgkin lymphoma with disease recurrence. METHODS: Case report and review of the literature. RESULTS: A 58-year-old immunocompetent male presented with aphasia. Neuroimaging revealed a left temporal lobe lesion. A craniotomy and resection were performed, and the diagnosis of classical Hodgkin lymphoma was made. Systemic work-up for lymphoma was negative. Postoperatively, the patient was treated with whole brain irradiation. 14 months later, the patient developed an enhancing lesion in his pons and received combination chemotherapy and radiation therapy. Repeat imaging demonstrated leptomeningeal enhancement and multiple lesions throughout the cerebral hemispheres, cerebellum and brainstem. COMMENT: We report what appears to be the first case of a patient with aggressive primary intracerebral Hodgkin lymphoma with disease recurrence.


Subject(s)
Brain Neoplasms/pathology , Hodgkin Disease/pathology , Neoplasm Recurrence, Local/pathology , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Brain Neoplasms/radiotherapy , Brain Neoplasms/surgery , Cranial Irradiation , Fatal Outcome , Hodgkin Disease/radiotherapy , Hodgkin Disease/surgery , Humans , Male , Middle Aged , Neoplasm Recurrence, Local/drug therapy , Neoplasm Recurrence, Local/radiotherapy , Neurosurgical Procedures
13.
Br J Cancer ; 101(12): 1986-94, 2009 Dec 15.
Article in English | MEDLINE | ID: mdl-19920819

ABSTRACT

BACKGROUND: We evaluated bevacizumab with metronomic etoposide among recurrent malignant glioma patients in a phase 2, open-label trial. METHODS: A total of 59 patients, including 27 with glioblastoma (GBM) and 32 with grade 3 malignant glioma, received 10 mg kg(-1) bevacizumab biweekly and 50 mg m(-2) etoposide daily for 21 consecutive days each month. The primary end point was a 6-month progression-free survival, and secondary end points included safety and overall survival. Vascular endothelial growth factor (VEGF), VEGFR-2, carbonic anhydrase 9 (CA9) and hypoxia-inducible factor-2alpha (HIF-2alpha) were assessed semiquantitatively in archival tumours using immunohistochemistry and were correlated with outcome. RESULTS: Among grade 3 and GBM patients, the 6-month progression-free survivals were 40.6% and 44.4%, the radiographic response rates were 22% and 37% and the median survivals were 63.1 and 44.4 weeks, respectively. Hypertension predicted better outcome among both grade 3 and GBM patients, whereas high CA9 and low VEGF were associated with poorer progression-free survival (PFS) among those with GBM. The most common grade > or = 3 adverse events included neutropaenia (24%), thrombosis (12%), infection (8%) and hypertension (3%). Two patients had asymptomatic, grade 1 intracranial haemorrhage and one on-study death occurred because of pulmonary embolism. CONCLUSION: Bevacizumab with metronomic etoposide has increased toxicity compared with previous reports of bevacizumab monotherapy. Its anti-tumour activity is similar to that of bevacizumab monotherapy or bevacizumab plus irinotecan. (ClinicalTrials.gov: NCT00612430).


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Brain Neoplasms/drug therapy , Glioma/drug therapy , Neoplasm Recurrence, Local/drug therapy , Administration, Oral , Adult , Aged , Antibodies, Monoclonal/administration & dosage , Antibodies, Monoclonal/adverse effects , Antibodies, Monoclonal, Humanized , Bevacizumab , Biomarkers, Tumor/analysis , Brain Neoplasms/mortality , Etoposide/administration & dosage , Etoposide/adverse effects , Female , Glioma/mortality , Humans , Male , Middle Aged , Treatment Failure , Vascular Endothelial Growth Factor A/antagonists & inhibitors
14.
J Voice ; 23(3): 269-76, 2009 May.
Article in English | MEDLINE | ID: mdl-18346865

ABSTRACT

Understanding pediatric voice development and laryngeal pathology is predicated on a detailed knowledge of the microanatomy of the layered structure of the vocal fold. Our current knowledge of this microanatomy and its temporal evolution is limited by the lack of pediatric specimen availability. By providing the capability to image pediatric vocal folds in vivo, a noninvasive microscopy technique could greatly expand the existing database of pediatric laryngeal microanatomy and could furthermore make longitudinal studies possible. A variety of natural-contrast optical imaging technologies, including optical frequency domain imaging (OFDI), full-field optical coherence microscopy (FF-OCM), and spectrally encoded confocal microscopy (SECM) have been recently developed for noninvasive diagnosis in adult patients. In this paper, we demonstrate the potential of these three techniques for laryngeal investigation by obtaining images of excised porcine vocal fold samples. In our study, OFDI allowed visualization of the vocal fold architecture deep within the tissue, from the superficial mucosa to the vocalis muscle. The micron-level resolution of SECM allowed investigation of cells and extracellular matrix fibrils from the superficial mucosa to the intermediate layer of the lamina propria (LP) (350 microm penetration depth). The large field of view (up to 700 microm), penetration depth (up to 500 microm), and resolution (2x2x1microm [XxYxZ]) of FF-OCM enabled comprehensive three-dimensional evaluation of the layered structure of the LP. Our results suggest that these techniques provide important and complementary cellular and structural information, which may be useful for investigating pediatric vocal fold maturation in vivo.


Subject(s)
Vocal Cords/growth & development , Animals , Extracellular Matrix , Image Interpretation, Computer-Assisted , Laryngeal Muscles/anatomy & histology , Laryngeal Muscles/growth & development , Microscopy, Confocal , Mucous Membrane/anatomy & histology , Mucous Membrane/growth & development , Swine , Tomography, Optical Coherence , Vocal Cords/anatomy & histology
15.
Opt Express ; 16(2): 1096-103, 2008 Jan 21.
Article in English | MEDLINE | ID: mdl-18542183

ABSTRACT

Polarization sensitive optical coherence tomography (PS-OCT) provides a cross-sectional image of birefringence in biological samples that is complementary in many applications to the standard reflectance-based image. Recent ex vivo studies have demonstrated that birefringence mapping enables the characterization of collagen and smooth muscle concentration and distribution in vascular tissues. Instruments capable of applying these measurements percutaneously in vivo may provide new insights into coronary atherosclerosis and acute myocardial infarction. We have developed a polarization sensitive optical frequency domain imaging (PS-OFDI) system that enables high-speed intravascular birefringence imaging through a fiber-optic catheter. The novel design of this system utilizes frequency multiplexing to simultaneously measure reflectance of two incident polarization states, overcoming concerns regarding temporal variations of the catheter fiber birefringence and spatial variations in the birefringence of the sample. We demonstrate circular cross-sectional birefringence imaging of a human coronary artery ex vivo through a flexible fiber-optic catheter with an A-line rate of 62 kHz and a ranging depth of 6.2 mm.


Subject(s)
Coronary Vessels/ultrastructure , Fiber Optic Technology/instrumentation , Image Enhancement/instrumentation , Microscopy, Polarization/instrumentation , Tomography, Optical Coherence/instrumentation , Equipment Design , Equipment Failure Analysis , Fiber Optic Technology/methods , Humans , Image Enhancement/methods , Microscopy, Polarization/methods , Optical Fibers , Reproducibility of Results , Sensitivity and Specificity , Tomography, Optical Coherence/methods
16.
Rev Neurol (Paris) ; 164(6-7): 588-94, 2008.
Article in French | MEDLINE | ID: mdl-18565358

ABSTRACT

RATIONALE: Second-line chemotherapy is disappointing in recurrent high-grade gliomas. Dramatic responses in recurrent high-grade gliomas have been reported in a recent monocentric trial with a novel association combining bevacizumab (anti-VEGF monoclonal antibody agent) and irinitecan. OBJECTIVE: To report the experience of the ANOCEF group (French speaking neuro-oncology association) using the bevacizumab-irinotecan combination in recurrent high-grade gliomas. METHODS: Eight centers were involved in this retrospective multicenter study. Bevacizumab-irinotecan was delivered as previously described in a compassional setting to non-selected patients suffering from a high-grade glioma (WHO grade III and IV). Response rate at two months of the onset of the treatment was analyzed using the Macdonald criteria. The toxicity profile of the treatment was also investigated. RESULTS: From 2006 to 2007, 77 patients were treated (median age: 52 years; median Karnofsky score: 70) for a recurrent high-grade glioma (49 grade IV, 28 grade III). At two months, the response rates were objective response=36% (54% in grade III and 27% in grade IV); stable disease=39%; progressive disease=13%; patients not evaluable because of a rapid fatal clinical deterioration=12%. Improvement was noted in 49% of patients. Among the main toxicities, we noted; intratumoral hemorrage (n=5 with spontaneous regression in three) and thromboembolic complications including venous thrombophlebitis (n=4), pulmonary embolism (n=2), myocardial infarction (n=1), grade III-IV hematotoxicity (n=2), reversible leukoencephalopathy (n=1). CONCLUSION: This retrospective multicenter study adds further arguments in favor of the promising results of this new combination and its potential rapidity of action in recurrent high-grade gliomas. Antiangiogenic agents expose the patients to a well-known risk of thromboembolic and hemorragic complications, necessitating careful follow-up and patient selection in light of the cardiovascular contraindications.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Brain Neoplasms/drug therapy , Glioma/drug therapy , Adult , Aged , Antibodies, Monoclonal/administration & dosage , Antibodies, Monoclonal, Humanized , Antineoplastic Agents, Phytogenic/administration & dosage , Antineoplastic Combined Chemotherapy Protocols/administration & dosage , Antineoplastic Combined Chemotherapy Protocols/adverse effects , Bevacizumab , Brain Neoplasms/pathology , Camptothecin/administration & dosage , Camptothecin/analogs & derivatives , Child, Preschool , Female , Glioma/pathology , Humans , Irinotecan , Magnetic Resonance Imaging , Male , Middle Aged , Neoplasm Recurrence, Local , Retrospective Studies
17.
Opt Lett ; 32(19): 2768-70, 2007 Oct 01.
Article in English | MEDLINE | ID: mdl-17909567

ABSTRACT

A technique for increasing the ranging depth in optical frequency domain imaging utilizing frequency encoding is presented. Ranging depth is enhanced by using two interferometer reference arms with different path lengths and independent modulation frequencies (25 and 50 MHz). With this configuration, the sensitivity decreases by 6 dB over a depth range of 7 mm, approximately a threefold improvement over the conventional optical frequency domain imaging technique. We demonstrate that the reference arm frequency separation, tuning speed, center wavelength, and instantaneous coherence length determine the signal-to-cross-talk ratio.


Subject(s)
Algorithms , Data Compression/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Signal Processing, Computer-Assisted , Tomography, Optical Coherence/methods , Fourier Analysis , Sensitivity and Specificity
18.
Food Addit Contam ; 24(10): 1131-7, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17886185

ABSTRACT

Fusarium proliferatum is a major cause of maize ear rot and fumonisin contamination and also can cause wheat kernel black point disease. The primary objective of this study was to determine whether nine F. proliferatum strains from wheat from Nepal can cause black point and fumonisin contamination in wheat kernels. For comparison, the study included three Fusarium strains from US maize. In test 1, all the strains but one produced significant symptoms of kernel black point; two strains decreased kernel yield; and four strains contaminated kernels with fumonisins B(1), B(2) and B(3) as determined by liquid chromatography-mass spectroscopy. Strain Ggm202 from Nepal, which produced the highest levels of fumonisins (mean = 49 microg g(-1)) on five wheat cultivars in test 1, was confirmed to produce fumonisins (mean = 38 microg g(-1)) on two cultivars in test 2. The data indicate a potential for fumonisin contamination of wheat infected with F. proliferatum.


Subject(s)
Edible Grain/microbiology , Fumonisins/metabolism , Fusarium/isolation & purification , Mycotoxins/biosynthesis , Triticum/microbiology , Chromatography, Liquid/methods , Food Contamination/analysis , Genetic Variation , Italy , Mass Spectrometry/methods , Nepal , Statistics as Topic , United States , Zea mays/microbiology
19.
Int J Food Microbiol ; 119(1-2): 47-50, 2007 Oct 20.
Article in English | MEDLINE | ID: mdl-17707105

ABSTRACT

As the 20th century ended, Fusarium mycotoxicology entered the age of genomics. With complete genomes of Fusarium graminearum and F. verticillioides and several Fusarium gene expression sequence databases on hand, researchers worldwide are working at a rapid pace to identify mycotoxin biosynthetic and regulatory genes. Seven classes of mycotoxin biosynthetic genes or gene clusters have been identified in Fusarium to date; four are polyketide synthase gene clusters for equisetin, fumonisins, fusarins, and zearalenones. Other Fusarium mycotoxin biosynthetic genes include a terpene cyclase gene cluster for trichothecenes, a cyclic peptide synthetase for enniatins, and a cytochrome P450 for butenolide. From the perspective of the United States Department of Agriculture, the ultimate goal of research on Fusarium molecular biology is to reduce mycotoxins in cereal grains. With this goal in mind, efforts have focused on identifying aspects of mycotoxin biosynthesis and regulation that can be exploited for mycotoxin control. New information on fungal and plant genomes and gene expression will continue to provide information on genes important for fungal-plant interactions and to facilitate the development of targeted approaches for breeding and engineering crops for resistance to Fusarium infection and mycotoxin contamination.


Subject(s)
Fusarium/genetics , Gene Expression Regulation , Genes, Fungal , Mycotoxins/genetics , Food Contamination/analysis , Food Contamination/prevention & control , Fusarium/metabolism , Multigene Family , Mycotoxins/biosynthesis
20.
Opt Lett ; 32(11): 1560-2, 2007 Jun 01.
Article in English | MEDLINE | ID: mdl-17546188

ABSTRACT

Noninvasive measurements of the scattering coefficients of optically turbid media using angle-resolved optical frequency-domain imaging (OFDI) are demonstrated. It is shown that, by incoherently averaging OFDI reflectance signals acquired at different backscattering angles, speckle noise is reduced, allowing scattering coefficients to be extracted from a single A-line with much higher accuracy than with measurements from conventional OFDI and optical coherence tomography systems. Modeling speckle as a random phasor sum, the relationship between the measurement accuracy and the number of compounded angles is derived. The sensitivity analysis is validated with measurements from a tissue phantom.


Subject(s)
Optics and Photonics , Tomography, Optical Coherence/methods , Calibration , Linear Models , Models, Statistical , Phantoms, Imaging , Probability , Refractometry , Regression Analysis , Reproducibility of Results , Scattering, Radiation
SELECTION OF CITATIONS
SEARCH DETAIL
...