Rev Chir Orthop Reparatrice Appar Mot ; 85(4): 397-403, 1999 Jul.
Article in French | MEDLINE | ID: mdl-10457560

ABSTRACT

Three fractures of the femoral neck after intramedullary nailing for diaphyseal fracture are reported. In two cases, the diagnosis was established after nailing but the iatrogenic etiology may be not sure because of an imperfect primary radiological exploration. The localisation of the entry point and the rigidity of Grosse-Kempf's nail could be a contributing factor of this exceptional complication.


Subject(s)
Femoral Fractures/surgery , Femoral Neck Fractures/etiology , Fracture Fixation, Intramedullary/adverse effects , Adult , Female , Femoral Fractures/diagnostic imaging , Femoral Neck Fractures/diagnostic imaging , Humans , Iatrogenic Disease , Male , Radiography