Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Biomed Anal ; 48(5): 1481-4, 2008 Dec 15.
Article in English | MEDLINE | ID: mdl-18993009

ABSTRACT

A simple, precise and accurate reversed-phase liquid chromatographic method has been developed for the simultaneous estimation of ambroxol hydrochloride and azithromycin in tablet formulations. The chromatographic separation was achieved on a Xterra RP18 (250 mm x 4.6 mm, 5 microm) analytical column. A Mixture of acetonitrile-dipotassium phosphate (30 mM) (50:50, v/v) (pH 9.0) was used as the mobile phase, at a flow rate of 1.7 ml/min and detector wavelength at 215 nm. The retention time of ambroxol and azithromycin was found to be 5.0 and 11.5 min, respectively. The validation of the proposed method was carried out for specificity, linearity, accuracy, precision, limit of detection, limit of quantitation and robustness. The linear dynamic ranges were from 30-180 to 250-1500 microg/ml for ambroxol hydrochloride and azithromycin, respectively. The percentage recovery obtained for ambroxol hydrochloride and azithromycin were 99.40 and 99.90%, respectively. Limit of detection and quantification for azithromycin were 0.8 and 2.3 microg/ml, for ambroxol hydrochloride 0.004 and 0.01 microg/ml, respectively. The developed method can be used for routine quality control analysis of titled drugs in combination in tablet formulation.


Subject(s)
Ambroxol/analysis , Anti-Bacterial Agents/analysis , Azithromycin/analysis , Expectorants/analysis , Ambroxol/chemistry , Azithromycin/chemistry , Calibration , Chromatography, High Pressure Liquid/instrumentation , Chromatography, High Pressure Liquid/methods , Dosage Forms , Expectorants/chemistry , Hydrogen-Ion Concentration , Molecular Structure , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Tablets/chemistry , Temperature
2.
J Chromatogr Sci ; 46(7): 649-52, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18718143

ABSTRACT

A simple, rapid, and precise reversed-phase liquid chromatographic method is developed for simultaneous determination of paracetamol, aceclofenac, and chlorzoxazone in their ternary mixtures of commercial pharmaceutical preparation. This method uses a Zorbax SB C18, 250 x 4.6 mm, 5 microm analytical column. Mobile phase is acetonitrile and buffer (40:60, v/v), buffer containing 50 mM orthophosporic acid; pH of the buffer is adjusted to 6 with 10% w/v sodium hydroxide solution. The instrumental settings are at a flow rate of 1 mL/min; the column temperature is 25 degrees C, and detector wavelength is 270 nm. The sample concentrations are measured on weight basis to avoid the internal standard. The method is validated and shown to be linear. The correlation coefficients for paracetamol, aceclofenac, and chlorzoxazone are 0.9981, 0.9990, and 0.9986, respectively. The recovery values for paracetamol, aceclofenac, and chlorzoxazone ranged from 100.7-101.4%, 100.4-101.0%, and 100.5-101.3%, respectively. The relative standard deviation for six replicates is always less than 2%. This HPLC method is successfully applied to the simultaneous quantitative analysis of the title drugs in tablets and can be applied for assay and dissolution test of tablets for the estimation of paracetamol, aceclofenac, and chlorozoxazone in their commercial samples.


Subject(s)
Acetaminophen/analysis , Chlorzoxazone/analysis , Chromatography, High Pressure Liquid/methods , Diclofenac/analogs & derivatives , Diclofenac/analysis , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...