ACS Appl Mater Interfaces ; 9(25): 21169-21180, 2017 Jun 28.
Article in English | MEDLINE | ID: mdl-28581710

ABSTRACT

Antimicrobial silver nanoparticle coatings have attracted interest for reducing prosthetic joint infection. However, few studies report in vivo investigations of the biotransformation of silver nanoparticles within the regenerating tissue and its impact on bone formation. We present a longitudinal investigation of the osseointegration of silver nanoparticle-coated additive manufactured titanium implants in rat tibial defects. Correlative imaging at different time points using nanoscale secondary ion mass spectrometry, transmission electron microscopy (TEM), histomorphometry, and 3D X-ray microcomputed tomography provided quantitative insight from the nano- to macroscales. The quality and quantity of newly formed bone is comparable between the uncoated and silver coated implants. The newly formed bone demonstrates a trabecular morphology with bone being located at the implant surface, and at a distance, at two weeks. Nanoscale elemental mapping of the bone-implant interface showed that silver was present primarily in the osseous tissue and colocalized with sulfur. TEM revealed silver sulfide nanoparticles in the newly regenerated bone, presenting strong evidence that the previously in vitro observed biotransformation of silver to silver sulfide occurs in vivo.


Subject(s)
Biotransformation , Animals , Coated Materials, Biocompatible , Metal Nanoparticles , Osseointegration , Rats , Silver , Surface Properties , Titanium , X-Ray Microtomography
2.
Adv Healthc Mater ; 6(11)2017 Jun.
Article in English | MEDLINE | ID: mdl-28321991

ABSTRACT

Joint replacement surgery is associated with significant morbidity and mortality following infection with either methicillin-resistant Staphylococcus aureus (MRSA) or Staphylococcus epidermidis. These organisms have strong biofilm-forming capability in deep wounds and on prosthetic surfaces, with 103 -104 microbes resulting in clinically significant infections. To inhibit biofilm formation, we developed 3D titanium structures using selective laser melting and then coated them with a silver nanolayer using atomic layer deposition. On bare titanium scaffolds, S. epidermidis growth was slow but on silver-coated implants there were significant further reductions in both bacterial recovery (p < 0.0001) and biofilm formation (p < 0.001). MRSA growth was similarly slow on bare titanium scaffolds and not further affected by silver coating. Ultrastructural examination and viability assays using either human bone or endothelial cells, demonstrated strong adherence and growth on titanium-only or silver-coated implants. Histological, X-ray computed microtomographic, and ultrastructural analyses revealed that silver-coated titanium scaffolds implanted into 2.5 mm defects in rat tibia promoted robust vascularization and conspicuous bone ingrowth. We conclude that nanolayer silver of titanium implants significantly reduces pathogenic biofilm formation in vitro, facilitates vascularization and osseointegration in vivo making this a promising technique for clinical orthopedic applications.


Subject(s)
Bone Substitutes/chemistry , Coated Materials, Biocompatible/chemistry , Implants, Experimental/microbiology , Methicillin-Resistant Staphylococcus aureus/growth & development , Nanostructures/chemistry , Neovascularization, Physiologic , Silver/chemistry , Staphylococcus epidermidis/growth & development , Titanium/chemistry , Animals , Cell Line, Tumor , Humans , Male , Rats , Rats, Wistar , Tibia/injuries , Tibia/metabolism , Tibia/microbiology , Tibia/pathology
3.
J Mater Sci Mater Med ; 27(6): 112, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27153828

ABSTRACT

A correlative imaging methodology was developed to accurately quantify bone formation in the complex lattice structure of additive manufactured implants. Micro computed tomography (µCT) and histomorphometry were combined, integrating the best features from both, while demonstrating the limitations of each imaging modality. This semi-automatic methodology registered each modality using a coarse graining technique to speed the registration of 2D histology sections to high resolution 3D µCT datasets. Once registered, histomorphometric qualitative and quantitative bone descriptors were directly correlated to 3D quantitative bone descriptors, such as bone ingrowth and bone contact. The correlative imaging allowed the significant volumetric shrinkage of histology sections to be quantified for the first time (~15 %). This technique demonstrated the importance of location of the histological section, demonstrating that up to a 30 % offset can be introduced. The results were used to quantitatively demonstrate the effectiveness of 3D printed titanium lattice implants.


Subject(s)
Bone and Bones/physiology , Tissue Scaffolds , Titanium , X-Ray Microtomography/methods , Animals , Bone Regeneration , Male , Prostheses and Implants , Rats , Rats, Wistar , Surface Properties