Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Med Robot Res ; 32018 Apr 20.
Article in English | MEDLINE | ID: mdl-30820482

ABSTRACT

By intervening during the early stage of gestation, fetal surgeons aim to correct or minimize the effects of congenital disorders. As compared to postnatal treatment of these disorders, such early interventions can often actually save the life of the fetus and also improve the quality of life of the newborn. However, fetal surgery is considered one of the most challenging disciplines within Minimally Invasive Surgery (MIS), owing to factors such as the fragility of the anatomic features, poor visibility, limited manoeuvrability, and extreme requirements in terms of instrument handling with precise positioning. This work is centered on a fetal laser surgery procedure treating placental disorders. It proposes the use of haptic guidance to enhance the overall safety of this procedure and to simplify instrument handling. A method is described that provides effective guidance by installing a forbidden region virtual fixture over the placenta, thereby safeguarding adequate clearance between the instrument tip and the placenta. With a novel application of all-optical ultrasound distance sensing in which transmission and reception are performed with fibre optics, this method can be used with a sole reliance on intraoperatively acquired data. The added value of the guidance approach, in terms of safety and performance, is demonstrated in a series of experiments with a robotic platform.

2.
Int J Comput Assist Radiol Surg ; 11(7): 1371-83, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26662203

ABSTRACT

PURPOSE: Minimally invasive surgery is becoming the standard treatment of care for a variety of procedures. Surgeons need to display a high level of proficiency to overcome the challenges imposed by the minimal access. Especially when operating on a dynamic organ, it becomes very difficult to align instruments reliably and precisely. In this paper, a hybrid rigid/continuum robotic system and a dedicated robotic control approach are proposed to assist the surgeon performing complex surgical gestures in a dynamic environment. METHODS: The proposed robotic system consists of a rigid robot arm on top of which a continuum robot is mounted in series. The continuum robot is locally actuated with McKibben muscles. A control scheme based on quadratic programming framework is adopted. It is shown that the framework allows enforcing a set of constraints on the pose of the tip, as well as of the instrument shaft, which is commanded to slide in and out through the entry point. RESULTS: Through simulation and experiments, it is shown how the robot tool tip is able to follow sinusoidal trajectories of 0.37 and 2 Hz, while maintaining the instrument shaft pivoting along the entry point. The positioning and tracking accuracy of such system are shown to lie below 4.7 mm in position and [Formula: see text] in angle. CONCLUSION: The results suggest a good potential for applying the proposed technology to assist the surgeon during complex robot-assisted interventions. It is also illustrated that even when using flexible hence relatively safe end-effectors, it is possible to reach acceptable tracking behaviour at relatively high frequencies.


Subject(s)
Heart Valve Prosthesis Implantation/instrumentation , Robotic Surgical Procedures/instrumentation , Heart Valve Prosthesis Implantation/methods , Humans , Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Patient Positioning , Robotic Surgical Procedures/methods , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...