Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
Metrologia ; 552018.
Article in English | MEDLINE | ID: mdl-30983634

ABSTRACT

A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using an alpha-gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478 keV gamma rays from neutron capture on 10B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024%. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6Li was determined to an overall uncertainty of 0.058%. We discuss the principle of the alpha-gamma method and present details of how the measurement was performed including the systematic effects. We also describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.

2.
Rev Sci Instrum ; 88(8): 083503, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28863637

ABSTRACT

We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.

3.
Article in English | MEDLINE | ID: mdl-31092963

ABSTRACT

Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electronantineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.

4.
Phys Rev Lett ; 119(4): 042502, 2017 Jul 28.
Article in English | MEDLINE | ID: mdl-29341742

ABSTRACT

We report the first result for the electron-antineutrino angular correlation (a coefficient) in free neutron ß decay from the aCORN experiment. aCORN uses a novel method in which the a coefficient is proportional to an asymmetry in proton time of flight for events where the ß electron and recoil proton are detected in delayed coincidence. Data are presented from a 15 month run at the NIST Center for Neutron Research. We obtained a=-0.1090±0.0030(stat)±0.0028(sys), the most precise measurement of the neutron a coefficient reported to date.

5.
Phys Rev Lett ; 116(24): 242501, 2016 Jun 17.
Article in English | MEDLINE | ID: mdl-27367385

ABSTRACT

The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the ß decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782 keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335±0.00005[stat]±0.00015[syst]. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14 keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582±0.00023[stat]±0.00062[syst]. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies.

6.
Phys Rev Lett ; 111(22): 222501, 2013 Nov 27.
Article in English | MEDLINE | ID: mdl-24329445

ABSTRACT

The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of τ(n)=(886.3±1.2[stat]±3.2[syst]) s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized 6Li deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI 6Li(n,t)4He thermal neutron cross section. In the current work, we measure the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally absorbing neutron detector. This direct approach does not rely on the 6Li(n,t)4He cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but is measured with a precision of 0.057%, which represents a fivefold improvement in the uncertainty. We verify the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is τ(n)=(887.7±1.2[stat]±1.9[syst]) s.

7.
J Res Natl Inst Stand Technol ; 110(3): 137-44, 2005.
Article in English | MEDLINE | ID: mdl-27308110

ABSTRACT

The program in fundamental neutron physics at the National Institute of Standards and Technology (NIST) began nearly two decades ago. The Neutron Interactions and Dosimetry Group currently maintains four neutron beam lines dedicated to studies of fundamental neutron interactions. The neutrons are provided by the NIST Center for Neutron Research, a national user facility for studies that include condensed matter physics, materials science, nuclear chemistry, and biological science. The beam lines for fundamental physics experiments include a high-intensity polychromatic beam, a 0.496 nm monochromatic beam, a 0.89 nm monochromatic beam, and a neutron interferometer and optics facility. This paper discusses some of the parameters of the beam lines along with brief presentations of some of the experiments performed at the facilities.

8.
J Res Natl Inst Stand Technol ; 110(4): 327-31, 2005.
Article in English | MEDLINE | ID: mdl-27308145

ABSTRACT

We measured the neutron decay lifetime by counting in-beam neutron decay recoil protons trapped in a quasi-Penning trap. The absolute neutron beam fluence was measured by capture in a thin (6)LiF foil detector with known efficiency. The combination of these measurements gives the neutron lifetime: τ n = (886.8 ± 1.2 ± 3.2) s, where the first (second) uncertainty is statistical (systematic) in nature. This is the most precise neutron lifetime determination to date using an in-beam method.

9.
J Res Natl Inst Stand Technol ; 110(4): 401-5, 2005.
Article in English | MEDLINE | ID: mdl-27308157

ABSTRACT

Currently, the beta-neutrino asymmetry has the largest uncertainty (4 %) of the neutron decay angular correlations. Without requiring polarimetry this decay parameter can be used to measure λ (ga/gv ), test Cabibbo-Kobayashi-Maskawa (CKM) unitarity limit scalar and tensor currents, and search for Charged Vector Current (CVC) violation. We propose to measure the beta-neutrino asymmetry coeffcient, a, using time-of-flight for the recoil protons. We hope to achieve a systematic uncertainty of σa / a ≈ 1.0 %. After tests at Indiana University's Low Energy Neutron Source (LENS), the apparatus will be moved to the National Institute of Standards and Technology (NIST) where the measurement can achieve a statistical uncertainty of 1 % to 2 % in about 200 beam days.

10.
J Res Natl Inst Stand Technol ; 110(4): 421-5, 2005.
Article in English | MEDLINE | ID: mdl-27308161

ABSTRACT

Beta decay of the neutron into a proton, electron, and electron antineutrino is occasionally accompanied by the emission of a photon. Despite decades of detailed experimental studies of neutron beta-decay, this rare branch of a fundamental weak decay has never been observed. An experiment to study the radiative beta-decay of the neutron is currently being developed for the NG-6 fundamental physics endstation at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR). The experiment will make use of the existing apparatus for the NIST proton-trap lifetime experiment, which can provide substantial background reduction by providing an electron-proton coincidence trigger. Tests and design of a detector for gamma-rays in the 10 keV to 200 keV range are under development. The need for a large solid-angle gamma-ray detector that can operate in a strong magnetic field and at low temperature has led us to consider scintillating crystals in conjunction with avalanche photodiodes. The motivation and experimental technique will be discussed.

11.
J Res Natl Inst Stand Technol ; 110(4): 431-6, 2005.
Article in English | MEDLINE | ID: mdl-27308163

ABSTRACT

A new method of measuring the electron-antineutrino angular correlation coefficient, little "a", from neutron decay-to be performed at the National Institute of Standards and Technology-will require an electron spectrometer that strongly suppresses backscattered electrons. A prototype consisting of six trapezoidal veto detectors arranged around a plastic scintillator has been tested with an electron beam produced by a Van de Graaff accelerator. The results of this test and its implications for the little "a" measurement are discussed.

12.
Phys Rev Lett ; 91(15): 152302, 2003 Oct 10.
Article in English | MEDLINE | ID: mdl-14611461

ABSTRACT

We report a new measurement of the neutron decay lifetime by the absolute counting of in-beam neutrons and their decay protons. Protons were confined in a quasi-Penning trap and counted with a silicon detector. The neutron beam fluence was measured by capture in a thin 6LiF foil detector with known absolute efficiency. The combination of these simultaneous measurements gives the neutron lifetime: tau(n)=(886.8+/-1.2[stat]+/-3.2[syst]) s. The systematic uncertainty is dominated by uncertainties in the mass of the 6LiF deposit and the 6Li(n,t) cross section. This is the most precise measurement of the neutron lifetime to date using an in-beam method.

13.
J Res Natl Inst Stand Technol ; 105(1): 11-23, 2000.
Article in English | MEDLINE | ID: mdl-27551583

ABSTRACT

We discuss the connection of high-energy gamma-ray measurements with precision atomic mass determinations. These rather different technologies, properly combined, are shown to lead to new values for the neutron mass and the molar Planck constant. We then proceed to describe the gamma-ray measurement process using the GAMS4 facility at the Institut Laue-Langevin and its application to a recent measurement of the 2.2 MeV deuteron binding energy and the neutron mass. Our paper concludes by describing the first crystal diffraction measurement of the 8.6 MeV (36)Cl binding energy.

14.
J Res Natl Inst Stand Technol ; 98(1): 135-144, 1993.
Article in English | MEDLINE | ID: mdl-28053463

ABSTRACT

The features of two fundamental neutron physics research stations at the NIST cold neutron research facility are described in some detail. A list of proposed initial experimental programs for these two stations is also given.

SELECTION OF CITATIONS
SEARCH DETAIL
...