1.
Biosensors (Basel) ; 13(7)2023 Jul 13.
Article in English | MEDLINE | ID: mdl-37504129

ABSTRACT

A methodology to enhance the sensitivity of long-period fiber gratings (LPFGs) based on the combination of three different enhancement approaches is presented; the methods here adopted are the working near mode transition (MT) of a cladding mode (CM), working near the turn-around point of a CM and the enhancement of the evanescent field of CMs by reducing the cladding diameter or by increasing the order number of CMs. In order to combine these enhancement methodologies, an electrostatic self-assembly (ESA) process was used to deposit a polymeric overlay, with a chosen thickness, onto the etched fiber. The add-layer sensitivity of the sensor was theoretically calculated, and the demonstration of the real applicability of the developed LPFG as a biosensor was performed by means of an IgG/anti-IgG immunoassay in human serum in a thermostated microfluidic system. The limits of detection (LODs) calculated by following different procedures (three times the standard deviation of the blank and the mean value of the residuals) were 6.9 × 10-8 µg/mL and 4.5 × 10-6 µg/mL, respectively. The calculated LODs demonstrate the effectiveness of the applied methodology for sensitivity enhancement.


Subject(s)
Biosensing Techniques , Humans , Biosensing Techniques/methods , Limit of Detection , Immunoassay
2.
Sensors (Basel) ; 22(8)2022 Apr 12.
Article in English | MEDLINE | ID: mdl-35458949

ABSTRACT

A new methodology to enhance the sensitivity of a long period fiber grating sensor (LPFG) at the Turn Around Point (TAP) is here presented. The LPFG sensor has been fabricated by etching the fiber up to 20.4 µm, until the sidelobes of dispersed LP0,2 cladding mode appeared near TAP in aqueous medium. The dual peak sensitivity of the sidelobes was found to be 16,044 nm/SRIU (surrounding refractive index units) in the RI range from 1.333 to 1.3335.

3.
Appl Opt ; 56(35): 9846-9853, 2017 Dec 10.
Article in English | MEDLINE | ID: mdl-29240135

ABSTRACT

In this paper, a detailed investigation on the modeling of long-period fiber grating (LPFG) sensors is discussed with the aim of providing a more realistic solution for their use in biosensing. Add-layer sensitivity, i.e., sensitivity of the sensor to an additional layer adhered onto the fiber surface, is quantified and a clear and complete analysis about the influence of the average thickness of the deposited biological sensing layers, as well as the change in refractive index of these layers, on the resonant wavelength of the cladding modes of an LPFG is provided. Add-layer sensitivity of LPFG sensors close to mode transition (MT) and also at turn-around point (TAP) are taken into account. Adsorbed layer thicknesses, as estimated from measured wavelength shifts of the LPFG, are found to have a good match with the values obtained through other measurement techniques.