Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pacing Clin Electrophysiol ; 46(8): 827-832, 2023 08.
Article in English | MEDLINE | ID: mdl-37382396

ABSTRACT

INTRODUCTION: Leadless pacemaker (LP) is a novel pacemaker that has been proven to be effective and safe; however, the majority of LPs in previous reports were the Medtronic Micra™ VR LP. We aim to evaluate the implant efficiency and clinical performance of the Aveir™ VR LP compared to the Micra™ VR LP. METHOD: We performed a retrospective analysis in two healthcare systems (Sparrow Hospital and Ascension Health System, Michigan) in patients implanted with LPs between January 1, 2018, and April 1, 2022. The parameters were collected at implantation, 3 months and 6 months. RESULTS: A total of 67 patients were included in the study. The Micra™ VR group had shorter time in the electrophysiology lab (41 ± 12 vs. 55 ± 11.5 min, p = .008) and shorter fluoroscopic time (6.5 ± 2.2 vs. 11.5 ± 4.5 min, p < .001) compared to the Aveir™ VR group. The Aveir™ VR group had a significantly higher implant pacing threshold compared to the Micra™ VR group (0.74 ± 0.34 mA vs. 0.5 ± 0.18 mA at pulse width 0.4 ms, p < .001), but no difference was found at 3 months and 6 months. There was no significant difference in the R-wave sensing and impedance and pacing percentage at implantation, 3 months, and 6 months. Complications of the procedure were rare. The mean projected longevity of the Aveir™ VR group was longer than the Micra™ VR group (18.8 ± 4.3 vs. 7.7 ± 0.75 years, p < .001). CONCLUSION: Implantation of the Aveir™ VR required longer laboratory and fluoroscopic time, but showed longer longevity at 6 months follow-up, compare to the Micra™ VR. Complications and lead dislodgement are rare.


Subject(s)
Pacemaker, Artificial , Virtual Reality , Humans , Retrospective Studies , Lipopolysaccharides , Equipment Design , Cardiac Pacing, Artificial/methods
2.
Structure ; 31(9): 1109-1120.e3, 2023 09 07.
Article in English | MEDLINE | ID: mdl-37348494

ABSTRACT

The chemical scaffolds of numerous therapeutics are polyketide natural products, many formed by bacterial modular polyketide synthases (PKS). The large and flexible dimeric PKS modules have distinct extension and reducing regions. Structures are known for all individual enzyme domains and several extension regions. Here, we report the structure of the full reducing region from a modular PKS, the ketoreductase (KR), dehydratase (DH), and enoylreductase (ER) domains of module 5 of the juvenimicin PKS. The modular PKS-reducing region has a different architecture than the homologous fatty acid synthase (FAS) and iterative PKS systems in its arrangement of domains and dimer interface. The structure reveals a critical role for linker peptides in the domain interfaces, leading to discovery of key differences in KR domains dependent on module composition. Finally, our studies provide insight into the mechanism underlying modular PKS intermediate shuttling by carrier protein (ACP) domains.


Subject(s)
Peptides , Polyketide Synthases , Polyketide Synthases/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...