Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 67(15)2022 07 27.
Article in English | MEDLINE | ID: mdl-35738248

ABSTRACT

Objective. In this paper, we focus on the dielectric and mechanical characterization of tissue-mimicking breast phantoms.Approach. Starting from recipes previously proposed by our research group, based on easy-to-handle, cheap and safe components (i.e. sunflower oil, deionized water, dishwashing liquid and gelatin), we produced and tested, both dielectrically and mechanically, more than 100 samples. The dielectric properties were measured from 500 MHz to 14 GHz, the Cole-Cole parameters were derived to describe the dielectric behaviour in a broader frequency range, and the results were compared with dielectric properties of human breastex vivotissues up to 50 GHz. The macroscale mechanical properties were measured by means of unconfined compression tests, and the impact of the experimental conditions (i.e. preload and test speed) on the measured Young's moduli was analysed. In addition, the mechanical contrast between healthy- and malignant-tissue-like phantoms was evaluated.Main results. The results agree with the literature in the cases in which the experimental conditions are known, demonstrating the possibility to fabricate phantoms able to mimic both dielectric and mechanical properties of breast tissues.Significance. In this work, for the first time, a range of materials reproducing all the categories of breast tissues were experimentally characterized, both from a dielectric and mechanical point of view. A large range of frequency were considered for the dielectric measurements and several combinations of experimental conditions were investigated in the context of the mechanical characterization. The proposed results can be useful in the design and testing of complementary or supplementary techniques for breast cancer detection based on micro/millimetre-waves, possibly in connection with other imaging modalities.


Subject(s)
Breast , Microwaves , Breast/diagnostic imaging , Elastic Modulus , Gelatin , Humans , Phantoms, Imaging
2.
Breast ; 45: 64-69, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30884340

ABSTRACT

PURPOSE: The evaluation of the surgical margin in breast conservative surgery is a matter of general interest as such treatments are subject to the critical issue of margin status as positive surgical margins can undermine the effectiveness of the procedure. The relatively unexplored ability of millimeter-wave (mm-wave) spectroscopy to provide insight into the dielectric properties of breast tissues was investigated as a precursor to their possible use in assessment of surgical margins. METHODS: We assessed the ability of a mm-wave system with a roughly hemispherical sensitive volume of ∼3 mm radius to distinguish malignant breast lesions in prospectively and consecutively collected tumoral and non-tumoral ex-vivo breast tissue samples from 91 patients. We characterized the dielectric properties of 346 sites in these samples, encompassing malignant, fibrocystic disease and normal breast tissues. An expert pathologist subsequently evaluated all measurement sites. RESULTS: At multivariate analysis, mm-wave dielectric properties were significantly correlated to histologic diagnosis and fat content. Further, using 5-fold cross-validation in a Bayesian logistic mixed model that considered the patient as a random effect, the mm-wave dielectric properties of neoplastic tissues were significantly different from normal breast tissues, but not from fibrocystic tissue. CONCLUSION: Reliable discrimination of malignant from normal, fat-rich breast tissue to a depth compatible with surgical margin assessment requirements was achieved with mm-wave spectroscopy.


Subject(s)
Breast Neoplasms/pathology , Breast Neoplasms/surgery , Dielectric Spectroscopy/statistics & numerical data , Margins of Excision , Mastectomy, Segmental , Adult , Aged , Aged, 80 and over , Bayes Theorem , Breast/pathology , Breast/surgery , Dielectric Spectroscopy/methods , Female , Fibrocystic Breast Disease/pathology , Fibrocystic Breast Disease/surgery , Humans , Logistic Models , Middle Aged , Multivariate Analysis , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
3.
Phys Med Biol ; 64(5): 055006, 2019 02 20.
Article in English | MEDLINE | ID: mdl-30650384

ABSTRACT

Millimeter (mm)-wave imaging has been recently proposed as a new technique for breast cancer detection, based on the significant dielectric contrast between healthy and tumor tissues. Here we propose a procedure to fabricate, electromagnetically characterize and preserve realistic breast tissue-mimicking phantoms for testing mm-wave imaging prototypes. Low-cost, non-toxic and easy-to-produce mixtures made of sunflower oil, water and gelatin were prepared and their dielectric properties were for the first time measured in the (0.5-50) GHz frequency range using a coaxial probe kit. Different oil and gelatin percentages were tested. An alternative recipe based on a waste-oil hardener was also proposed. Finally, water and sunflower oil were investigated as preservation media. The mixtures electromagnetic properties were in good agreement with those of human breast ex vivo samples. By changing the ingredient concentrations or using different solidifying agents it was possible to mimic different tissue types. Besides, we show that sunflower oil represents an effective preservation medium for the developed materials. The first breast phantom mimicking a tumor mass into healthy tissues up to 50 GHz was also successfully fabricated. Results demonstrated the potential of the designed recipes to mimic breast tissues with different biological characteristics, preserving dielectric properties over time. Thus, this study represents a fundamental step towards the development of heterogeneous breast phantoms able to mimic the electromagnetic behavior of healthy and tumor tissues for mm-wave imaging applications.


Subject(s)
Breast/cytology , Breast/diagnostic imaging , Microwaves , Molecular Imaging/instrumentation , Phantoms, Imaging , Breast/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Gelatin , Humans , Sunflower Oil , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...