Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Philos Trans A Math Phys Eng Sci ; 379(2204): 20200195, 2021 Aug 23.
Article in English | MEDLINE | ID: mdl-34218668

ABSTRACT

Multimodal imaging is an active branch of research as it has the potential to improve common medical imaging techniques. Diffuse optical tomography (DOT) is an example of a low resolution, functional imaging modality that typically has very low resolution due to the ill-posedness of its underlying inverse problem. Combining the functional information of DOT with a high resolution structural imaging modality has been studied widely. In particular, the combination of DOT with ultrasound (US) could serve as a useful tool for clinicians for the formulation of accurate diagnosis of breast lesions. In this paper, we propose a novel method for US-guided DOT reconstruction using a portable time-domain measurement system. B-mode US imaging is used to retrieve morphological information on the probed tissues by means of a semi-automatical segmentation procedure based on active contour fitting. A two-dimensional to three-dimensional extrapolation procedure, based on the concept of distance transform, is then applied to generate a three-dimensional edge-weighting prior for the regularization of DOT. The reconstruction procedure has been tested on experimental data obtained on specifically designed dual-modality silicon phantoms. Results show a substantial quantification improvement upon the application of the implemented technique. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 2'.


Subject(s)
Image Interpretation, Computer-Assisted/statistics & numerical data , Multimodal Imaging/statistics & numerical data , Tomography, Optical/statistics & numerical data , Ultrasonography/statistics & numerical data , Algorithms , Breast Neoplasms/diagnostic imaging , Female , Fourier Analysis , Humans , Image Enhancement/methods , Imaging, Three-Dimensional/statistics & numerical data , Linear Models , Phantoms, Imaging
2.
Opt Lett ; 46(2): 424-427, 2021 Jan 15.
Article in English | MEDLINE | ID: mdl-33449045

ABSTRACT

Fast time-gated single-photon detectors demonstrated high depth sensitivity in the detection of localized absorption perturbations inside scattering media, but their use for in vivo clinical applications-such as functional imaging of brain activation-was impaired by their small (<0.04mm2) active area. Here, we demonstrate, both on phantoms and in vivo, the performance of a fast-gated digital silicon photomultiplier (SiPM) that features an overall active area of 8.6mm2, overcoming the photon collection capability of established time-gated single-pixel detectors by orders of magnitude, enabling deep investigations within scattering media and high signal-to-noise ratios at late photon arrival times.

3.
Biomed Opt Express ; 11(11): 6389-6412, 2020 Nov 01.
Article in English | MEDLINE | ID: mdl-33282497

ABSTRACT

Two main bottlenecks prevent time-domain diffuse optics instruments to reach their maximum performances, namely the limited light harvesting capability of the detection chain and the bounded data throughput of the timing electronics. In this work, for the first time to our knowledge, we overcome both those limitations using a probe-hosted large area silicon photomultiplier detector coupled to high-throughput timing electronics. The system performances were assessed based on international protocols for diffuse optical imagers showing better figures with respect to a state-of-the-art device. As a first step towards applications, proof-of-principle in-vivo brain activation measurements demonstrated superior signal-to-noise ratio as compared to current technologies.

4.
Opt Lett ; 43(11): 2450-2453, 2018 Jun 01.
Article in English | MEDLINE | ID: mdl-29856401

ABSTRACT

We demonstrate time domain diffuse correlation spectroscopy at quasi-null source-detector separation by using a fast time-gated single-photon avalanche diode without the need of time-tagging electronics. This approach allows for increased photon collection, simplified real-time instrumentation, and reduced probe dimensions. Depth discriminating, quasi-null distance measurement of blood flow in a human subject is presented. We envision the miniaturization and integration of matrices of optical sensors of increased spatial resolution and the enhancement of the contrast of local blood flow changes.


Subject(s)
Blood Flow Velocity/physiology , Spectrum Analysis/methods , Adult , Female , Humans , Optical Fibers , Photons , Scattering, Radiation
5.
Rev Sci Instrum ; 87(7): 073101, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27475542

ABSTRACT

We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm(2) together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).

6.
Biomed Opt Express ; 4(10): 2257-68, 2013.
Article in English | MEDLINE | ID: mdl-24156081

ABSTRACT

We report on the design and first in vivo tests of a novel non-contact scanning imaging system for time-domain near-infrared spectroscopy. Our system is based on a null source-detector separation approach and utilizes polarization-selective detection and a fast-gated single-photon avalanche diode to record late photons only. The in-vivo tests included the recording of hemodynamics during arm occlusion and two brain activation tasks. Localized and non-localized changes in oxy- and deoxyhemoglobin concentration were detected for motor and cognitive tasks, respectively. The tests demonstrate the feasibility of non-contact imaging of absorption changes in deeper tissues.

SELECTION OF CITATIONS
SEARCH DETAIL
...