Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Jpn Circ J ; 65(11): 979-83, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11716251

ABSTRACT

The estimation of global left ventricular function using M-mode echocardiography has technical limitations in the murine model of myocardial infarction (MI), but the recent improvements in 2-dimensional (2-D) echocardiography using a high-frequency transducer provide more accessible images. Furthermore, intravenous injection of contrast agent has the additional benefit of enhancing the endocardial border in the murine heart. The present study was designed to evaluate the value of 2-D echocardiography with intravenous injection of contrast agent in the assessment of global systolic function of the murine heart with MI. Two-dimensional and M-mode echocardiography without and with intravenous injection of contrast agent (Optison, 0.1-0.15 ml) were performed in 76 awake mice 2 days before and 2 days after left coronary artery ligation. Fractional shortening (FS) was calculated from the end-diastolic and end-systolic diameters on M-mode echocardiography, and fractional area change (FAC) from the end-diastolic and end-systolic areas on 2-D echocardiography. Both FS and FAC were compared with the areas of hypoperfusion observed in the pathological samples. The use of contrast agent improved the number of hearts that could be evaluated by both the M-mode and 2-D method (M-mode: non-contrast 87% vs contrast 99%, p<0.01; 2-D: non-contrast 26% vs contrast 89%, p<0.001). FAC from the 2-D method correlated better with the region of hypoperfusion in the pathological samples than did FS from the M-mode method (FAC: r=0.84 vs FS: r=0.51). In conclusion, FAC obtained from 2-D contrast echocardiography is useful for noninvasive assessment of global systolic function in infarcted murine hearts and can be used to serially assess systolic function in various models of the murine heart.


Subject(s)
Echocardiography/standards , Myocardial Infarction/diagnostic imaging , Ventricular Dysfunction, Left/diagnosis , Albumins/administration & dosage , Albumins/adverse effects , Albumins/pharmacology , Animals , Contrast Media/administration & dosage , Contrast Media/adverse effects , Contrast Media/pharmacology , Disease Models, Animal , Echocardiography/methods , Fluorocarbons/administration & dosage , Fluorocarbons/adverse effects , Fluorocarbons/pharmacology , Heart/drug effects , Male , Mice , Myocardial Infarction/diagnosis , Ventricular Dysfunction, Left/diagnostic imaging
2.
J Am Soc Echocardiogr ; 14(8): 806-12, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11490329

ABSTRACT

The objective of this study was to prospectively assess pulmonary venous anastomosis by transesophageal echocardiography after lung transplantation. Thrombus formation at the pulmonary venous anastomotic site after lung transplantation may have catastrophic consequences, including allograft failure and stroke. Eighty-seven consecutive adult lung transplant recipients underwent transesophageal echocardiography within 48 hours after surgery. Thrombosis of a pulmonary vein was diagnosed in 13 (15%) of 87 patients in the early postoperative period after lung transplantation. Mean thrombus width was 0.9 +/- 0.4 cm (range, 0.5 to 1.7 cm), with an average peak flow velocity at the site of obstruction of 127 +/- 23 cm/s (range, 90 to 150 cm/s). Five patients with pulmonary vein thrombosis died in the perioperative period, yielding a 90-day mortality rate of 38%. Larger thrombus size and greater acceleration of flow through a narrowed pulmonary vein correlated with poor clinical outcome. During each year of the study, the incidence of pulmonary vein thrombosis declined progressively. Pulmonary vein thrombosis is a potentially ominous complication in the early postoperative period after lung transplantation. Transesophageal echocardiography is a valuable tool for detecting abnormalities of the pulmonary venous anastomosis. Thrombus size and flow velocity at the anastomotic site may guide prognosis and clinical management. Complications of the pulmonary venous anastomosis are in part technical in nature.


Subject(s)
Echocardiography, Transesophageal , Lung Transplantation/adverse effects , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Venous Thrombosis/diagnostic imaging , Venous Thrombosis/etiology , Adult , Aged , Anastomosis, Surgical , Female , Humans , Lung Transplantation/diagnostic imaging , Lung Transplantation/physiology , Male , Middle Aged , Postoperative Care , Postoperative Complications , Prospective Studies , Pulmonary Veins/physiopathology , Time Factors , Venous Thrombosis/physiopathology
3.
J Womens Health Gend Based Med ; 8(10): 1273-9, 1999 Dec.
Article in English | MEDLINE | ID: mdl-10643835

ABSTRACT

Postmenopausal estrogen replacement therapy (ERT) has been associated with a reduced risk of coronary artery disease (CAD). Whether this apparent cardioprotective effect is mediated by a cardiovascular benefit during exercise, however, has not been clearly defined. To evaluate rest and exercise variables with and without ERT, a randomized crossover trial was conducted in 23 postmenopausal women, ranging in age from 44 to 75 years, mean age 57+/-8 years. The rest and exercise variables were compared on ERT and during a drug-free period. The baseline measure was compared to the effects after 4 weeks of ERT and after 4 drug-free weeks. Echocardiographic treadmill exercise variables of heart rate (HR), blood pressure, rate-pressure product (RPP), and cardiac dimensions were determined at baseline and at the end of each treatment period. In response to ERT, there was a decrease in low-density lipoprotein (LDL) cholesterol (drug-free: 142+/-40 mg/dl, ERT: 124+/-34 mg/dl) and an increase in high-density lipoprotein (HDL) cholesterol (drug-free: 52+/-14 mg/dl, ERT: 62+/-15 mg/dl, both p<0.01). At rest, the study population had no overall significant change in HR, blood pressure, RPP, or left ventricular end-systolic and end-diastolic diameters when ERT was compared to the drug-free period. However, subjects with the fastest baseline resting HR had the greatest decrease in HR with ERT relative to the drug-free period (p<0.05). During exercise, ERT effected no change in peak HR, blood pressure, or RPP, although end-systolic diameter decreased slightly (p<0.05). With ERT, subject age correlated negatively with systolic blood pressure (p<0.05) and RPP (p<0.01); both blood pressure and RPP decreased in older subjects. In conclusion, ERT has differential effects dependent on baseline HR and age.


Subject(s)
Coronary Disease/prevention & control , Echocardiography/drug effects , Estrogen Replacement Therapy , Estrogens, Conjugated (USP)/administration & dosage , Exercise Test/drug effects , Adult , Aged , Cholesterol, HDL/blood , Cholesterol, LDL/blood , Coronary Disease/diagnostic imaging , Cross-Over Studies , Estrogens, Conjugated (USP)/adverse effects , Female , Hemodynamics/drug effects , Humans , Middle Aged , Postmenopause , Risk Factors , Single-Blind Method
4.
Heart Vessels ; 14(3): 143-8, 1999.
Article in English | MEDLINE | ID: mdl-10776807

ABSTRACT

Transcutaneous ultrasonography is a non-invasive technique with the ability to measure the volumetric blood flow of the peripheral circulation. Peripheral blood flow can be determined by high-resolution imaging of vessel diameter coupled with Doppler assessment of flow velocity. This method, however, has not been validated in vivo. Accordingly, brachial artery flow in response to intraarterial infusion of vasodilators was assessed by ultrasonography in 16 healthy subjects and compared to values obtained simultaneously by venous occlusion plethysmography. Blood flow calculated from ultrasound-derived vessel diameter and flow velocity was found to highly correlate with plethysmographic flow, with r values ranging from 0.83 to 0.99. Using this ultrasound technique combined with plethysmography, the response of conduit and resistance vessels to endothelium-mediated vasodilation was characterized. Doppler velocity rose dramatically with endothelium-dependent acetylcholine (970%), but only modestly with endothelium-independent vasodilators, nitroglycerin (292%) and nitroprusside (340%). Despite eliciting the greatest overall forearm flow response, acetylcholine resulted in a smaller increase in conduit diameter (15.4%) than nitroglycerin (21.8%), and only a comparable change than nitroprusside (14.6%). Taken together, these results suggest that acetylcholine acts predominantly on resistance vessels, whereas nitrovasodilators affect mainly conduit vessels. In summary, transcutaneous ultrasonography can be used reliably to assess flow changes in the peripheral circulation. Combined with plethysmography, this technique is useful for determining the relative contribution of conduit and resistance vessels to peripheral flow, particularly in the assessment of endothelium-mediated vasodilation.


Subject(s)
Blood Circulation/physiology , Endothelium, Vascular/physiology , Plethysmography , Ultrasonography, Doppler, Pulsed , Vasodilation/physiology , Adult , Blood Flow Velocity , Brachial Artery , Female , Humans , Linear Models , Male , Regional Blood Flow
5.
J Am Soc Echocardiogr ; 11(2): 209-12, 1998 Feb.
Article in English | MEDLINE | ID: mdl-9517561

ABSTRACT

Thrombus formation at the pulmonary venous anastomotic site after lung transplantation may have catastrophic consequences, including allograft failure and stroke. However, treatment with systemic anticoagulation may facilitate bleeding in the early postoperative period. In the present report, we describe the clinical and transesophageal echocardiographic findings of pulmonary venous thrombosis in two patients in the immediate postoperative period after lung transplantation. Treatment with systemic anticoagulation was not feasible because of extensive postoperative thoracic bleeding in each instance. A conservative approach was taken on the basis of the small size of each thrombus and lack of accelerated flow velocity at the site of the thrombus. Each thrombus resolved spontaneously without clinical sequelae. These two cases suggest that thrombus size and flow velocity at the anastomotic site may be used to guide the clinical management of pulmonary venous thrombosis after lung transplantation.


Subject(s)
Lung Transplantation , Pulmonary Veins , Thrombosis/diagnostic imaging , Adult , Anastomosis, Surgical/adverse effects , Echocardiography, Transesophageal , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Remission, Spontaneous , Thrombosis/etiology
6.
J Am Soc Echocardiogr ; 10(7): 763-7, 1997 Sep.
Article in English | MEDLINE | ID: mdl-9339431

ABSTRACT

Although abnormalities of the pulmonary venous anastomosis in the early postoperative period after lung transplantation have been reported from several centers, late complications related to the pulmonary venous anastomosis have not been described. In the present study, we describe the clinical and transesophageal echocardiographic findings of pulmonary vein anastomotic complications in two patients at 1.9 and 2.3 years after lung transplantation. Both pulmonary venous abnormalities, stenosis in the first instance and thrombosis in the second instance, impaired venous outflow on the affected side causing unilateral edema and pleural effusion. Pulmonary venous abnormalities late after lung transplantation can mimic allograft rejection, opportunistic infection, or heart failure and are best diagnosed by transesophageal echocardiography.


Subject(s)
Anastomosis, Surgical/adverse effects , Echocardiography, Transesophageal , Lung Transplantation/adverse effects , Pulmonary Veins/diagnostic imaging , Blood Flow Velocity , Cardiac Output, Low/diagnosis , Constriction, Pathologic/diagnostic imaging , Constriction, Pathologic/etiology , Diagnosis, Differential , Edema/diagnostic imaging , Edema/etiology , Fatal Outcome , Female , Follow-Up Studies , Graft Rejection/diagnosis , Humans , Male , Middle Aged , Opportunistic Infections/diagnosis , Pleural Effusion/diagnostic imaging , Pleural Effusion/etiology , Pulmonary Veins/pathology , Regional Blood Flow , Thrombosis/diagnostic imaging , Thrombosis/etiology
7.
Am J Cardiol ; 80(6): 793-7, 1997 Sep 15.
Article in English | MEDLINE | ID: mdl-9315595

ABSTRACT

To assess the peripheral vascular effects of estrogen in women without coronary disease, normal postmenopausal women (mean age 56 +/- 8 years) participated in a randomized, crossover trial using treadmill exercise echocardiography, and received oral conjugated estrogen, 0.625 mg/day or underwent a drug-free period. There was no significant effect on heart rate, blood pressure, double product, left ventricular end-systolic and end-diastolic diameters, or electrocardiographic measures after estrogen. In contrast to the profound effects reported in patients with cardiac disease, oral estrogen in normal women does not bestow significant benefit on treadmill exercise echocardiographic variables at rest or during modest levels of exercise.


Subject(s)
Estrogens, Conjugated (USP)/pharmacology , Exercise Test/drug effects , Hemodynamics/drug effects , Postmenopause/drug effects , Adult , Aged , Cross-Over Studies , Echocardiography , Electrocardiography/drug effects , Estradiol/blood , Female , Humans , Middle Aged , Postmenopause/physiology , Rest , Single-Blind Method
8.
Transplantation ; 62(5): 622-5, 1996 Sep 15.
Article in English | MEDLINE | ID: mdl-8830826

ABSTRACT

BACKGROUND: The purpose of this study was to assess by echocardiography the effects of lung transplantation on recovery of right ventricular (RV) function in patients with preoperative RV dysfunction. METHODS: Fourteen (20%) of 71 lung transplant recipients were identified by echocardiography as manifesting abnormal RV function before lung transplantation. These 14 patients were selected for follow-up echocardiographic study 8 months after transplantation. RESULTS: RV function improved significantly in the study group. Mean RV end-diastolic area decreased from 26.8 +/- 7.9 cm2 to 20.1 +/- 4.7 cm2 (P < 0.01); mean RV end-systolic area decreased from 21.5 +/- 6.8 cm2 to 13.1 +/- 4.2 (P < 0.01); and mean RV fractional area change (FAC) increased from 20.4 +/- 3.3% to 35.8 +/- 8.9% (P < 0.001). A subgroup of four patients, however, exhibited no change in RV function. Patients who achieved improvement in RV function tended to be younger, had shorter duration of disease before transplantation, and had higher pulmonary arterial (PA) pressures before transplantation (PA systolic, 89 +/- 28 mmHg vs. 38 +/- 11 mmHg, P < 0.001; PA diastolic, 42 +/- 11 mmHg vs. 19 +/- 3 mmHg, P < 0.002). Each of the eight patients with primary pulmonary hypertension exhibited improvement in RV function (mean delta FAC +20.6 +/- 5.9%), while two of three patients with emphysema and both patients with idiopathic pulmonary fibrosis failed to achieve improvement in RV function (mean delta FAC +2.3 +/- 1.2%). CONCLUSIONS: Improvement of RV function assessed by echocardiography occurs after lung transplantation, even in patients with severe preoperative RV dysfunction. However, the degree of improvement is variable and may depend on the degree of RV after-load reduction and the presence or absence of intrinsic myocardial disease. RV ejection parameters do not distinguish between these two possibilities.


Subject(s)
Lung Transplantation , Ventricular Dysfunction, Right , Ventricular Function, Right/physiology , Adolescent , Adult , Aged , Echocardiography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...