Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Vasc Surg ; 72: 578-588, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33157243

ABSTRACT

Surgical site infection (SSIs) in lower extremity vascular procedures is a major contributor to patient morbidity and mortality. Despite previous advancements in preoperative and postoperative care, the surgical infection rate in vascular surgery remains high, particularly when groin incisions are involved. However, successfully targeting modifiable risk factors reduces the surgical site infection incidence in vascular surgery patients. We conducted an extensive literature review to evaluate the efficacy of various preventive strategies for groin surgical site infections. We discuss the role of preoperative showers, preoperative and postoperative antibiotics, collagen gentamicin implants, iodine impregnated drapes, types of skin incisions, negative pressure wound therapy, and prophylactic muscle flap transposition in preventing surgical site infection in the groin after vascular surgical procedures.


Subject(s)
Groin/blood supply , Surgical Wound Infection/prevention & control , Vascular Surgical Procedures/adverse effects , Humans , Risk Assessment , Risk Factors , Surgical Wound Infection/diagnosis , Surgical Wound Infection/microbiology , Treatment Outcome
2.
J Surg Educ ; 76(2): 554-559, 2019.
Article in English | MEDLINE | ID: mdl-30121166

ABSTRACT

BACKGROUND: Image-guided microwave ablation (MWA) is a technically demanding procedure, involving advanced visual-spatial perception skills. This study sought to create and evaluate a low-cost model and training curriculum for open ultrasound-guided liver tumor MWA. METHODS: Simulated tumors were created, implanted into bovine livers, and visualized by ultrasound. A high-fidelity abdominal model was constructed, with a total cost of $30. Experienced physicians in MWA performed simulated ablations and evaluated the model. Expert performance metrics were established and served as targets for our training curriculum. These included time, number of passes, number of repositionings, and percentage of tumor ablated. Next, 8 novice trainees completed our deliberate practice curriculum. Participants' performances were recorded throughout. RESULTS: Physicians completed a structured feedback questionnaire rating the model's realism and training utility at 8/10 and 10/10, respectively. Tumors appeared hyperechoic and were clearly visualized on ultrasound. Trainees performed a total of 32 ablations. Our trainees' performance improved significantly in all outcomes of interest in the postcurriculum ablations compared to precurriculum ablations. CONCLUSION: We have created a cost-effective, high-fidelity model of MWA, with a deliberate practice curriculum. Trainees can practice to proficiency with clear target metrics prior to participating in clinical cas.


Subject(s)
Ablation Techniques/education , Curriculum , Hepatectomy/education , Liver Neoplasms/surgery , Models, Educational , Surgery, Computer-Assisted/education , Ultrasonography, Interventional , Animals , Cattle , Hepatectomy/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...