Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Publication year range
1.
PLoS One ; 17(8): e0269313, 2022.
Article in English | MEDLINE | ID: mdl-36018880

ABSTRACT

INTRODUCTION: The aim of this study was to describe and evaluate a novel plate designed specifically for the canine ilium using finite element methods. The cranial portion of the plate had an elliptical shape and contained nine screw holes. The caudal portion of the plate was triangular with three screw holes. Four and three screws were used at the cranial (screw 1 to 4) and caudal (screw 5 to 7) segment of the plate. Finite element models of the plate and canine pelvis were created. A load of 300 N was applied on the femur-hip joint contact area. Values of Von Mises Stress on the plate, screws and the maximum and minimum main stresses in the bone were used to capture the mechanical factors in this study. RESULTS: The novel implant had a plate stress of 51.9 megapascals (MPa) with higher stress in the dorsal part of the plate. Screws 2 and 4 showed similar stress values of 17.3 MPa. Screws 1 and 3 were the most loaded (51.9 MPa and 75 MPa, respectively). Screws 5, 6, and 7 showed similar dissipation and stress values (21.55 MPa). There was traction force in the dorsal region of the pubis and compression in the ventral part, with dissipation and values of 15.4 MPa and 23.9 MPa, respectively, acquiring balance between them. CONCLUSION: The novel plate is potentially applicable and specifically suitable for iliac fractures in dogs. The screws distribution modeled proved itself strategical since the simulated stresses were evenly distributed throughout the implant construct.


Subject(s)
Fracture Fixation, Internal , Spinal Fractures , Animals , Biomechanical Phenomena , Bone Plates , Bone Screws , Dogs , Finite Element Analysis , Stress, Mechanical
2.
PLoS One ; 14(8): e0220291, 2019.
Article in English | MEDLINE | ID: mdl-31381582

ABSTRACT

The objective of this study was to evaluate the use of a lyophilized and gamma-sterilized allogeneic freeze-dried bone wedge as a spacer for advancement of a modified tibial tuberosity (mTTA) in 16 knees that were clinically diagnosed with cranial cruciate ligament disease. Patients underwent radiography before the surgical procedure as well as immediately after surgery and at 30, 60, 90 and 120 days post-surgery, and their locomotion was evaluated at the same time points except for the immediate postoperative period. The surgical wounds were evaluated for signs of infection and rejection of the bone implant. Locomotion was graded on a scale of 0-5, with 0 indicating no limping and 5 indicating limb functional impotence. The "tibial-tibial bone-tibial implant" interfaces were evaluated radiographically, and each interface was assigned scores of 0-3, with 0 indicating no contact between the implant and adjacent bone and 3 indicating a bone bridge throughout the interface. The patients showed good clinical and radiographic recovery. The lyophilized bone spacer allowed for easy storage and transport and rapid and satisfactory execution of mTTA while showing resistance to drilling and fixation with screws in 87.5% of cases and a mean surgical time of 45.9 minutes. No immunogenic reactions were observed in 93.7% of the cases. One patient presented infection of the surgical focus, which showed remission after antimicrobial therapy. All patients showed functional recovery of the operated limb, with the number of clinically healthy patients being higher than those with claudication at 120 days (p ≤ 0.05). In all patients, it was possible to verify the incorporation of the bone implant into the tibia. Bone union occurred progressively, and the degrees of bone union observed on radiographs at postoperative days 60, 90, and 120 were significantly greater (p < 0.05) than those observed in the immediate postoperative period and at 30 days.


Subject(s)
Allografts , Anterior Cruciate Ligament Injuries/surgery , Bone Transplantation , Gamma Rays , Osteotomy/methods , Sterilization , Tibia/surgery , Allografts/radiation effects , Animals , Anterior Cruciate Ligament Injuries/physiopathology , Dogs , Freeze Drying , Recovery of Function , Treatment Outcome
3.
Pesqui. vet. bras ; 39(8): 643-648, Aug. 2019. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1040730

ABSTRACT

Canine hip dysplasia (CHD) is a common condition observed in the surgical clinics for small animals. Among the surgical techniques for management of CHD, triple pelvic osteotomy and sacroiliac wedge promote acetabular lateral axial rotation (ventroversion), increasing acetabular coverage and joint stability. The present study aimed to evaluate radiographically, by measuring the Norberg angle (NA) and the acetabular coverage percentage (ACP), the acetabular ventroversion induced by the sacroiliac wedge technique, with or without pelvic osteotomies; we also checked the feasibility of wedges made of polyamide with an angulation of 20° and 30°. The software used to measure NA and ACP was AutoCAD® 2009. Pelves from 10 canine corpses were evaluated radiographically at four time-points: M0 (Control Group), M1 (wedges of 20° and 30°), M2 and M3 (wedges associated with bilateral pubis and ischium osteotomies, respectively). There was no significant increase in the acetabular ventroversion at M1, M2, and M3. The polyamide sacroiliac wedge technique proved to be feasible, stable, and easy to apply. Further, the software proved to be efficient and easy to use for NA and ACP measurements. In the present study, even in the cases of non-dysplasic adult canine corpses, it was concluded that the sacroiliac wedge technique does not require to be accompanied by pubis and ischial osteotomies because they did not significantly increase the NA and ACP.(AU)


A displasia coxofemoral (DCF) é afecção comum na clínica cirúrgica de pequenos animais. Entre as técnicas cirúrgicas para controle da DCF, a osteotomia pélvica tripla (OPT) e a cunha sacroilíaca (CSI), promovem rotação lateral acetabular no eixo axial (ventroversão), aumentando a cobertura acetabular e a estabilidade da articulação. Desta forma, o presente estudo objetivou avaliar radiograficamente, por meio da aferição do ângulo de Norberg (NA) e da porcentagem de cobertura acetabular (PCA), a ventroversão acetabular induzida pela técnica da cunha sacroilíaca, associada ou não às osteotomias pélvicas, além de verificar a exequibilidade das cunhas confeccionadas de poliamida com angulação de 20ο e 30ο. O software utilizado para aferir o AN e o PCA foi o AutoCAD® 2009. Dez pelves de cadáveres caninos foram avaliadas radiograficamente em quatro momentos: MO (Grupo Controle), M1 (cunhas de 20ο e 30ο), M2 e M3 (cunhas associadas à osteotomia bilateral do púbis e ísquio, respectivamente). Não houve aumento significativo da ventroversão em M1, M2 e M3. A técnica de cunha sacroilíaca de poliamida mostrou-se exequível, estável e de fácil aplicação. Não obstante, o software utilizado mostrou-se eficiente e de fácil utilização nas aferições do AN e PCA. Neste estudo, mesmo tratando-se de cadáveres de cães adultos e de maioria não displásicos, concluiu-se que a utilização da técnica de cunha sacroilíaca não necessita de associação à ostectomia púbica e a osteotomia do ísquio por não promoverem aumento significativo do AN e da PCA.(AU)


Subject(s)
Animals , Dogs , Osteotomy/veterinary , Sacroiliac Joint/surgery , Hip Dysplasia, Canine/diagnosis , Hip Joint/surgery , Cadaver
4.
Vet Comp Orthop Traumatol ; 32(3): 234-240, 2019 May.
Article in English | MEDLINE | ID: mdl-30943549

ABSTRACT

OBJECTIVE: The aim of this study was to compare in vitro accuracy of femoral measurements obtained from different radiographical positions with actual femoral anatomical dimensions in dogs. MATERIALS AND METHODS: Craniocaudal projections of the femur in ventrodorsal position, standard craniocaudal radiographical (SR) and craniocaudal radiography with horizontal radiographical beam (HR), in addition to anatomical macroscopic measurements (A), were obtained from 45 femurs from 23 canine cadavers, for calculation of the canal flare index (CFI). The differences between the radiographical positions and 95% limits of agreement (LOA) between the CFI-SR, CFI-HR and CFI-A were evaluated by the Bland-Altman method. RESULTS: The standard craniocaudal radiograph provided an approximate dimension of the proximal femoral morphology (mean difference: 0.121 ± 0.391) with a different CFI value (p = 0.0341) from CFI-A. The craniocaudal radiograph taken using a horizontal beam provided greater accuracy (mean difference: 0.087 ± 0.42) in our study. CLINICAL SIGNIFICANCE: The craniocaudal projection using a horizontal radiographical beam was more accurate than the standard craniocaudal projection for measurement of the true anatomical dimensions of the canine femur, minimizing the influence of the technique on the CFI values.


Subject(s)
Dogs/anatomy & histology , Femur/diagnostic imaging , Radiography/veterinary , Animals , Cadaver , Female , Male , Radiography/methods
5.
Pesqui. vet. bras ; 38(7): 1376-1381, July 2018. ilus
Article in English | LILACS, VETINDEX | ID: biblio-976446

ABSTRACT

The aim of this study was to describe and analyse the adaptability and functionality of tie-in configuration in tibial osteosynthesis in dogs. Twenty dogs with tibial fracture were included in this study. An orifice was made on the proximal tibial fragment, on the medial side, close to the tibial crest. The drill piece was angled at 45º and projected into the same orifice on the distal sense of the bone. Others orifices made with the aid of a low rotation drill and drill piece with diameter smaller than the chosen implant. After 10 days post-operative, the animals were evaluated. X-ray analysis was performed at the time of clinical examination; immediate post-operative period; and at 30, 60, 90, and 120 days post-surgery. A questionnaire was given to the owners to provide details on the post-operative period. There were no trans-operative complications or suture dehiscence up to the day of suture removal. Partial development of bone callus was observed in 20 dogs within a mean period of 76 days. Three animals showed bone consolidation within 35 days, nine by 60 days, three by 90 days, and 5 by 120 days post-operative. Dynamization was carried out in 9 animals. The surgical access to the tibial medullary canal through the orifice at the proximal medial face, by the tibial tuberosity, enables the insertion of IMP without risks to articular and peri-articular lesions in the knee in dogs.(AU)


O objetivo deste trabalho foi descrever e analisar a funcionalidade da configuração tie-in na ostessíntese de tíbia em cães. Foram usados 21 cães com fratura de tíbia da rotina clinica do hospital veterinário. Somente a primeira cortical (Sis) foi perfurada, em seguida a broca foi inclinada a 45o e projetada no mesmo orifício no sentido distal do osso. foram confeccionados outros orifícios com auxílio de furadeira de baixa rotação e broca cujo diâmetro era menor que o implante escolhido. Os procedimentos radiográficos foram realizados no momento do atendimento clínico, no período pós-operatório imediato e aos 30, 60, 90 e 120 dias pós-cirúrgico. Não houve nenhuma complicação transoperatória, tão pouco deiscência de sutura até o momento da retirada dos pontos de cútis. A formação parcial de calo ósseo foi evidenciada em 20 cães com tempo médio de 76 dias. Três cães obtiveram consolidação óssea em 35 dias, nove aos 60 dias, três aos 90 dias e cinco aos 120 dias de pós-operatório. Dinamizações foram realizadas em nove animais. Após a confirmação radiográfica de consolidação óssea, os implantes dos 20 animais foram totalmente removidos. Concluiu-se que o acesso cirúrgico ao canal medular da tíbia canina por meio de orifício na face medial proximal, junto à tuberosidade da tíbia, permite a inserção do PIM sem risco de lesões articulares e periarticulares no joelho.(AU)


Subject(s)
Animals , Dogs , Postoperative Care/veterinary , Dogs/abnormalities , Fracture Fixation, Internal/veterinary , Fracture Fixation, Internal/statistics & numerical data
6.
Pesqui. vet. bras ; 34(2): 192-198, fev. 2014. ilus
Article in Portuguese | LILACS | ID: lil-709865

ABSTRACT

O exame ultrassonográfico ocular é indispensável no pré-operatório de procedimentos cirúrgicos intraoculares como a facectomia, além de ser uma ferramenta complementar ao exame oftalmológico, em casos de perda da transparência dos meios ópticos. A inexistência de estudos acerca de padrões de normalidades para as medidas do bulbo ocular e de suas estruturas internas nos gatos, cujos valores possibilitam o monitoramento de enfermidades e auxiliam em procedimentos cirúrgicos motivaram este estudo. Utilizaram-se 40 gatos, adultos, machos e fêmeas, livres de enfermidades sistêmica e oftalmológica. Destes, 22 eram da raça persa (grupo braquicefálico - GB) e 18 sem raça definida (grupo não braquicefálico - GNB). A biometria ultrassonográfica ocular transcorneana foi realizada, em modo-B∕A, com o transdutor microlinear de 9 MHz e as medidas D1 (profundidade da câmara anterior), D2 (diâmetro do cristalino), D3 (profundidade da câmara vítrea) e D4 (diâmetro axial do bulbo ocular) aferidas. Ainda, mensuraram-se as distâncias fronto-occipital e bizigomática e o peso desses animais. Os dados obtidos foram analisados pelo teste-t pareado, seguindo-se as análises de variância e covariância, além da regressão linear múltipla relacionando-se as medidas de D1, D2, D3 e D4 às medidas bizigomática e fronto-occipital, como também à idade, ao peso e ao gênero. Obteve-se como resultado a média de D1, D2, D3 e D4, assim como dos diâmetros bizigomático e fronto-occipital, idade e peso, verificando-se diferenças significativas para D4 nas fêmeas de GB. Houve, pela análise de regressão linear, influência do peso, idade e diâmetro fronto-occipital sobre D1, D2 e D4 nos gatos do GB, e dos diâmetros bizigomático sobre D1, D3 e D4 nos gatos do GNB. Conclui-se que houve diferença no diâmetro axial do bulbo ocular nas fêmeas do GB, e que o peso, a idade e os diâmetros cranianos influenciam a biometria ocular dos gatos braquicefálicos e não braquicefálicos.


Ocular ultrasonography is a helpful ophthalmic examination, performed on the absence of transparency in ocular means and frequently requested prior intraocular surgery. Unfortunately, the lack of studies upon ultrasonografic images of the normal feline eye, difficults the evaluation of its biometry and its inner structures in many ophthalmic diseases and also before surgery. The objective of this study was to evaluate the ocular biometry and the morphometric parameters of the cranium of 40 healthy adult cats, including 22 Persian cats (Brachycephalic group - BG) and 18 Mixed-breed cats (Noun brachycephalic group - NBG). B/A-mode ultrasonographic biometry, utilizing a 9 MHz probe, was performed for depth of the anterior chamber (D1), lens axial length (D2), depth of the vitreous chamber (D3) and axial length of the globe (D4). Morphometric parameters of the cranium were obtained for bizygomatic (BZ) and occipital frontal (OF) diameters. Data was collected and statistical analysis, including "t" paired tests, variance and covariance analysis and multiple linear regressions was performed for every obtained measure and also for animal ages, weigh and gender. Statistic relevant values were observed in D4 parameter for female cats of BG. Multiple linear regression indicated some influence of the weigh, age and OF in D1, D2 and D4 of PG; and of BZ in D1, D3 and D4 of NBG. Besides that, it was observed that biometry was also influenced by weigh, age and morphometric parameters of their craniums in both groups.


Subject(s)
Animals , Cats , Biometry , Skull/anatomy & histology , Cats/anatomy & histology , Eye/anatomy & histology , Reference Standards , Ultrasonography/veterinary , Preoperative Care/veterinary , Cataract Extraction/veterinary , Ocular Physiological Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL
...