Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38955627

ABSTRACT

BACKGROUND: There is limited data on cardiac output in patients with small aortic annuli undergoing trans-catheter aortic valve implantation (TAVI) according to the implanted platform of balloon-expandable (BEV) compared to self-expanding valves (SEV). METHODS: This is a retrospective analysis of consecutive patients with severe aortic stenosis and small annuli who underwent successful TAVI. Cardiac output was measured using echocardiography within 4 weeks following TAVI. Data were recorded and analysed by an experienced operator who was not aware of the type of the implanted valve. RESULTS: 138 patients were included in the analysis, of whom 57 % underwent TAVI with BEV. Clinical and echocardiographic characteristics were comparable between the two platforms, except for more frequent previous cardiac surgery and smaller indexed aortic valve in the BEV group. There was no relationship between computed tomography-derived aortic annulus area and cardiac output post TAVI. When compared to patients who underwent TAVI with BEV, those with SEV had larger cardiac output [mean difference - 0.50 l/min, 95 % CI (-0.99, -0.01)] and cardiac index [mean difference - 0.20 l/min/m2, 95 % CI (-0.47, 0.07)], although the latter did not reach statistical significance. Unlike patients with small body surface area, in those with large body surface area both cardiac output and cardiac index were statistically larger in patients who underwent SEV compared to BEV. CONCLUSION: Cardiac output, as measured by echocardiography, was larger in patients with small annuli who underwent TAVI procedure with SEV compared to BEV. Such difference was more evident in patients with large body surface area.

2.
Eur Heart J Case Rep ; 8(2): ytae040, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38332920

ABSTRACT

Background: Transcatheter aortic valve implantation (TAVI) is an established treatment for patients with symptomatic severe aortic stenosis. Patients with previous renal transplant are considered as a high-risk cohort who may develop procedural complications related to vascular access and renal impairment post-TAVI. Case summary: Herein, we report a case of an 88-year-old male who presented with progressive dyspnoea. His transthoracic echocardiogram revealed severe aortic stenosis with a peak gradient of 75 mmHg and impaired left ventricle systolic function (an estimated ejection fraction of 40%). He had a background of kidney transplant with progressive decline in renal function, requiring the formation of left arm arteriovenous fistula in preparation for future dialysis. He was successfully treated with TAVI using a single vascular access site without administering contrast media. Discussion: Single-access, non-contrast TAVI is feasible when treating renal transplant patients with severe aortic stenosis and limited vascular access. The current minimalistic approach should be used only in highly selective patient cases.

SELECTION OF CITATIONS
SEARCH DETAIL
...