Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 320: 124544, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38850822

ABSTRACT

Long-term studies have shown a bias drift over time in the prediction performance of near-infrared spectroscopy measurement systems. This bias drift generally requires extra laboratory reference measurements to detect and correct for this bias. Since these reference measurements are expensive and time consuming, there is a need for advanced methodologies for bias drift monitoring and correction without the need for taking extra samples. In this study, we propose and validate a method to monitor the bias drift and two methods to tackle it. The first method requires no extra measurements and uses a modified version of Partial Least Squares Regression to estimate and correct the bias. This method is based on the assumption that the mean concentration of the predicted component remains constant over time. The second method uses regular bulk milk measurements as a reference for bias correction. This method compares the measured concentrations of the bulk milk to the volume-weighted average concentrations of individual milk samples predicted by the sensor. Any difference between the actual and calculated bulk milk composition is then used to perform a bias correction on the predictions by the sensor system. The effectiveness of these methods to improve the component prediction was evaluated on data originating from a custom-built sensor that automatically measures the NIR reflectance and transmittance spectra of raw milk on the farm. We evaluate the practical use case where models for predicting the milk composition are trained upon installation of the sensor at the farm, and later used to predict the composition of subsequent samples over a period of more than 6 months. The effectiveness of the fully unsupervised method was confirmed when the mean concentration of the milk samples remained constant, while the effectiveness reduced when this was not the case. The bulk milk correction method was effective when all relevant samples for the component were measured by the sensor and included in the analyzed bulk milk, but is less effective when samples included in the bulk which are not measured by the sensor system. When the necessary conditions are met, these methods can be used to extend the lifetime of deployed prediction models by significantly reducing the bias on the predicted values.

2.
Data Brief ; 51: 109767, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38075623

ABSTRACT

Monitoring of milk composition can support several dimensions of dairy management such as identification of the health status of individual dairy cows and the safeguarding of dairy quality. The quantification of milk composition has been traditionally executed employing destructive chemical or laboratory Fourier-transform infrared (FTIR) spectroscopy analyses which can incur high costs and prolonged waiting times for continuous monitoring. Therefore, modern technology for milk composition quantification relies on non-destructive near-infrared (NIR) spectroscopy which is not invasive and can be performed on-farm, in real-time. The current dataset contains NIR spectral measurements in transmittance mode in the wavelength range from 960 nm to 1690 nm of 1224 individual raw milk samples, collected on-farm over an eight-week span in 2017, at the experimental dairy farm of the province of Antwerp, 'Hooibeekhoeve' (Geel, Belgium). For these spectral measurements, laboratory reference values corresponding to the three main components of raw milk (fat, protein and lactose), urea and somatic cell count (SCC) are included. This data has been used to build multivariate calibration models to predict the three milk compounds, as well as develop strategies to monitor the prediction performance of the calibration models.

3.
Foods ; 10(11)2021 Nov 03.
Article in English | MEDLINE | ID: mdl-34828968

ABSTRACT

Today, measurement of raw milk quality and composition relies on Fourier transform infrared spectroscopy to monitor and improve dairy production and cow health. However, these laboratory analyzers are bulky, expensive and can only be used by experts. Moreover, the sample logistics and data transfer delay the information on product quality, and the measures taken to optimize the care and feeding of the cattle render them less suitable for real-time monitoring. An on-farm spectrometer with compact size and affordable cost could bring a solution for this discrepancy. This paper evaluates the performance of microelectromechanical system (MEMS)-based near-infrared (NIR) spectrometers as on-farm milk analyzers. These spectrometers use Fabry-Pérot interferometers for wavelength tuning, giving them the advantage of very compact size and affordable price. This study discusses the ability of MEMS spectrometers to reach the accuracy limits set by the International Committee for Animal Recording (ICAR) for at-line analyzers of the milk content regarding fat, protein and lactose. According to the achieved results, the transmission measurements with the NIRONE 2.5 spectrometer perform best, with an acceptable root mean squared error of prediction (RMSEP = 0.21% w/w) for the measurement of milk fat and excellent performance (RMSEP ≤ 0.11% w/w) for protein and lactose. In addition, the transmission measurements using the NIRONE 2.0 module give similar results for fat and lactose (RMSEP of 0.21 and 0.10% w/w respectively), while the prediction of protein is slightly deteriorated (RMSEP = 0.15% w/w). These results show that the MEMS spectrometers can reach sufficient prediction accuracy compared to ICAR standard values for at-line and in-line fat, protein and lactose prediction.

4.
Sensors (Basel) ; 20(21)2020 Oct 23.
Article in English | MEDLINE | ID: mdl-33113922

ABSTRACT

Work-related musculoskeletal disorders are a major concern globally affecting societies, companies, and individuals. To address this, a new sensor-based system is presented: the Smart Workwear System, aimed at facilitating preventive measures by supporting risk assessments, work design, and work technique training. The system has a module-based platform that enables flexibility of sensor-type utilization, depending on the specific application. A module of the Smart Workwear System that utilizes haptic feedback for work technique training is further presented and evaluated in simulated mail sorting on sixteen novice participants for its potential to reduce adverse arm movements and postures in repetitive manual handling. Upper-arm postures were recorded, using an inertial measurement unit (IMU), perceived pain/discomfort with the Borg CR10-scale, and user experience with a semi-structured interview. This study shows that the use of haptic feedback for work technique training has the potential to significantly reduce the time in adverse upper-arm postures after short periods of training. The haptic feedback was experienced positive and usable by the participants and was effective in supporting learning of how to improve postures and movements. It is concluded that this type of sensorized system, using haptic feedback training, is promising for the future, especially when organizations are introducing newly employed staff, when teaching ergonomics to employees in physically demanding jobs, and when performing ergonomics interventions.


Subject(s)
Ergonomics , Musculoskeletal Diseases , Wearable Electronic Devices , Feedback , Humans , Musculoskeletal Diseases/prevention & control , Posture
5.
J Dairy Sci ; 103(7): 6422-6438, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32389474

ABSTRACT

In high-yielding dairy cattle, severe postpartum negative energy balance is often associated with metabolic and infectious disorders that negatively affect production, fertility, and welfare. Mobilization of adipose tissue associated with negative energy balance is reflected through an increased level of nonesterified fatty acids (NEFA) in the blood plasma. Earlier, identification of negative energy balance through detection of increased blood plasma NEFA concentration required laborious and stressful blood sampling. More recently, attempts have been made to predict blood NEFA concentration from milk samples. In this study, we aimed to develop and validate a model to predict blood plasma NEFA concentration using the milk mid-infrared (MIR) spectra that are routinely measured in the context of milk recording. To this end, blood plasma and milk samples were collected in wk 2, 3, and 20 postpartum for 192 lactations in 3 herds. The blood plasma samples were taken in the morning, and representative milk samples were collected during the morning and evening milk sessions on the same day. To predict plasma NEFA concentration from the milk MIR spectra, partial least squares regression models were trained on part of the observations from the first herd. The models were then thoroughly validated on all other observations of the first herd and on the observations of the 2 independent herds to explore their robustness and wide applicability. The final model could accurately predict blood plasma NEFA concentrations <0.6 mmol/L with a root mean square error of prediction of <0.143 mmol/L. However, for blood plasma with >1.2 mmol/L NEFA, the model clearly underestimated the true level. Additionally, we found that morning blood plasma NEFA levels were predicted with significantly higher accuracy using MIR spectra of evening milk samples compared with MIR spectra of morning samples, with root mean square error of prediction values of, respectively, 0.182 and 0.197 mmol/L, and R2 values of 0.613 and 0.502. These results suggest a time delay between variations in blood plasma NEFA and related milk biomarkers. Based on the MIR spectra of evening milk samples, cows at risk for negative energy status, indicated by detrimental morning blood plasma NEFA levels (>0.6 mmol/L), could be identified with a sensitivity and specificity of, respectively, 0.831 and 0.800. As this model can be applied to millions of historical and future milk MIR spectra, it opens an opportunity for regular metabolic screening and improved resilience phenotyping.


Subject(s)
Fatty Acids, Nonesterified/blood , Milk/chemistry , Spectrophotometry, Infrared/veterinary , 3-Hydroxybutyric Acid/blood , Animals , Cattle , Diagnostic Tests, Routine , Energy Metabolism , Fatty Acids, Nonesterified/chemistry , Female , Fertility , Humans , Lactation , Postpartum Period , Predictive Value of Tests , Sensitivity and Specificity
6.
Sensors (Basel) ; 19(5)2019 Mar 11.
Article in English | MEDLINE | ID: mdl-30862019

ABSTRACT

Preventive healthcare has attracted much attention recently. Improving people's lifestyles and promoting a healthy diet and wellbeing are important, but the importance of work-related diseases should not be undermined. Musculoskeletal disorders (MSDs) are among the most common work-related health problems. Ergonomists already assess MSD risk factors and suggest changes in workplaces. However, existing methods are mainly based on visual observations, which have a relatively low reliability and cover only part of the workday. These suggestions concern the overall workplace and the organization of work, but rarely includes individuals' work techniques. In this work, we propose a precise and pervasive ergonomic platform for continuous risk assessment. The system collects data from wearable sensors, which are synchronized and processed by a mobile computing layer, from which exposure statistics and risk assessments may be drawn, and finally, are stored at the server layer for further analyses at both individual and group levels. The platform also enables continuous feedback to the worker to support behavioral changes. The deployed cloud platform in Amazon Web Services instances showed sufficient system flexibility to affordably fulfill requirements of small to medium enterprises, while it is expandable for larger corporations. The system usability scale of 76.6 indicates an acceptable grade of usability.


Subject(s)
Biosensing Techniques , Musculoskeletal Diseases/physiopathology , Wearable Electronic Devices , Ergonomics/methods , Humans , Occupational Diseases/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...