Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 157
Filter
1.
Gastrointest Endosc ; 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38692518

ABSTRACT

BACKGROUND AND AIMS: Glucagon-like peptide-1 receptor agonists (GLP-1 RAs) promote weight loss by suppressing appetite, enhancing satiety, regulating glucose metabolism and delaying gastric motility. We sought to determine whether GLP-1 RA use could impact sedated medical procedures like esophagogastroduodenoscopy (EGD). METHODS: We conducted a retrospective study on 35,183 patients who underwent EGD between 2019 and 2023, 922 of which were using a GLP-1-RA. Data were collected regarding demographics, diabetes status, retained gastric contents during EGD (RGC), incidence of aborted EGD, and necessity for repeat EGD. RESULTS: GLP-1 RA use was associated with a fourfold increase in the retention of gastric contents (p<0.0001), fourfold higher rates of aborted EGD (p<0.0001), and twice the likelihood of requiring repeat EGD (p=0.0001), even after stratifying for presence of diabetes. CONCLUSIONS: GLP-1 RA use can lead to delayed gastric emptying, affecting EGD adequacy regardless of the presence of diabetes, and may warrant dose adjustment to improve safety and efficacy of these procedures.

3.
Dis Esophagus ; 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38659256

ABSTRACT

Esophageal manometry is utilized for the evaluation and classification of esophageal motility disorders. EndoFlip has been introduced as an adjunctive test to evaluate esophagogastric junction (EGJ) distensibility. Treatment options for achalasia and EGJ outflow obstruction (EGJOO) include pneumatic dilation, myotomy, and botulinum toxin. Recently, a therapeutic 30 mm hydrostatic balloon dilator (EsoFLIP, Medtronic, Minneapolis, MN, USA) has been introduced, which uses impedance planimetry technology like EndoFlip. We performed a systematic review to evaluate the safety and efficacy of EsoFLIP in the management of esophageal motility disorders. A systematic literature search was performed with Medline, Embase, Web of science, and Cochrane library databases from inception to November 2022 to identify studies utilizing EsoFLIP for management of esophageal motility disorders. Our primary outcome was clinical success, and secondary outcomes were adverse events. Eight observational studies including 222 patients met inclusion criteria. Diagnoses included achalasia (158), EGJOO (48), post-reflux surgery dysphagia (8), and achalasia-like disorder (8). All studies used 30 mm maximum balloon dilation except one which used 25 mm. The clinical success rate was 68.7%. Follow-up duration ranged from 1 week to a mean of 5.7 months. Perforation or tear occurred in four patients. EsoFLIP is a new therapeutic option for the management of achalasia and EGJOO and appears to be effective and safe. Future comparative studies with other therapeutic modalities are needed to understand its role in the management of esophageal motility disorders.

5.
Gastrointest Endosc ; 99(6): 1035-1038, 2024 06.
Article in English | MEDLINE | ID: mdl-38316225

ABSTRACT

BACKGROUND AND AIMS: The SpyGlass (Boston Scientific, Marlborough, Mass, USA) single-operator cholangioscopy (SOC) system is generally considered to be safe but adds additional risks to those associated with standard ERCP. METHODS: We evaluated adverse events (AEs) associated with the SpyGlass system reported in the U.S. Food and Drug Administration Manufacturer and User Facility Device Experience database between January 2016 and August 2023. RESULTS: From the database, 2311 device problems (SpyGlass DS, 1301; SpyGlass DS II, 1010) were reported. An optical problem was the most reported issue (SpyGlass DS, 83; SpyGlass DS II, 457). Patient-related events were found in 62 of 1743 reports (3.5%): 33 with the SpyGlass DS and 29 with the SpyGlass DS II. The most common AEs were bleeding/hemorrhage followed by perforation; infection, fever, or sepsis; and pancreatitis. CONCLUSIONS: Our findings add to the existing literature and provide a fuller picture of potential problems associated with the SpyGlass SOC.


Subject(s)
Databases, Factual , Endoscopy, Digestive System , Humans , Endoscopy, Digestive System/adverse effects , Endoscopy, Digestive System/methods , Endoscopy, Digestive System/instrumentation , United States , Pancreatitis/etiology , Sepsis/etiology , Equipment Failure , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Cholangiopancreatography, Endoscopic Retrograde/methods , Intestinal Perforation/etiology , United States Food and Drug Administration , Hemorrhage/etiology , Gastrointestinal Hemorrhage/etiology
6.
J Clin Gastroenterol ; 58(2): 131-135, 2024 02 01.
Article in English | MEDLINE | ID: mdl-36753462

ABSTRACT

BACKGROUND METHODS: The question prompt list content was derived through a modified Delphi process consisting of 3 rounds. In round 1, experts provided 5 answers to the prompts "What general questions should patients ask when given a new diagnosis of Barrett's esophagus" and "What questions do I not hear patients asking, but given my expertise, I believe they should be asking?" Questions were reviewed and categorized into themes. In round 2, experts rated questions on a 5-point Likert scale. In round 3, experts rerated questions modified or reduced after the previous rounds. Only questions rated as "essential" or "important" were included in Barrett's esophagus question prompt list (BE-QPL). To improve usability, questions were reduced to minimize redundancy and simplified to use language at an eighth-grade level (Fig. 1). RESULTS: Twenty-one esophageal medical and surgical experts participated in both rounds (91% males; median age 52 years). The expert panel comprised of 33% esophagologists, 24% foregut surgeons, and 24% advanced endoscopists, with a median of 15 years in clinical practice. Most (81%), worked in an academic tertiary referral hospital. In this 3-round Delphi technique, 220 questions were proposed in round 1, 122 (55.5%) were accepted into the BE-QPL and reduced down to 76 questions (round 2), and 67 questions (round 3). These 67 questions reached a Flesch Reading Ease of 68.8, interpreted as easily understood by 13 to 15 years olds. CONCLUSIONS: With multidisciplinary input, we have developed a physician-derived BE-QPL to optimize patient-physician communication. Future directions will seek patient feedback to distill the questions further to a smaller number and then assess their usability.


Subject(s)
Barrett Esophagus , Physicians , Male , Humans , Middle Aged , Female , Barrett Esophagus/diagnosis , Delphi Technique , Communication , Physician-Patient Relations , Surveys and Questionnaires
8.
Gastrointest Endosc ; 99(6): 931-937, 2024 06.
Article in English | MEDLINE | ID: mdl-38141686

ABSTRACT

BACKGROUND AND AIMS: EUS-guided liver biopsy (EUS-LB) sampling is being increasingly used. We performed a prospective randomized trial to compare specimen adequacy of a 19-gauge fine-needle biopsy (FNB) needle with a 22-gauge FNB Franseen tip needle for EUS-LB sampling. METHODS: Forty-two consecutive patients referred for EUS-LB sampling were prospectively randomized to a 19-gauge or 22-gauge FNB needle. When the specimen with the 22-gauge needle was macroscopically inadequate, an additional pass with the 19-gauge needle was done. Bilobar EUS-LB sampling was performed with heparinized wet suction using 1 pass and 3 actuations per lobe. Descriptive statistics were computed for all variables. RESULTS: Biopsy sampling was performed for abnormal liver enzymes in 95.5% of patients (57% women; average age, 51 years). Five patients undergoing sampling with the 22-gauge FNB needle had macroscopically inadequate specimens and required additional biopsy sampling with the 19-gauge FNB needle. Mean preprocessing length of the longest tissue core was 21.5 ± 6.3 mm with a 19-gauge FNB needle compared with 9.4 ± 5.5 mm with the 22-gauge FNB needle (P < .001). Postprocessing specimens were significantly longer with 19-gauge than with 22-gauge FNB needles (17.4 mm vs 6.8, P < .001). There were no adverse events, and postprocedure pain and discomfort was similar in both groups (14% for 19-gauge vs 10% for 22-gauge, P = .99). CONCLUSIONS: Liver core biopsy sampling using the 19-gauge FNB needle is superior to the 22-gauge FNB needle in terms of length of longest core and aggregate specimen length. Considerably more fragmentation of the 22-gauge cores occurs during tissue processing. No increased postprocedure pain or AEs were found with the 19-gauge needle. A 19-gauge FNB needle is preferred to the 22-gauge FNB needle for EUS-LB. (Clinical trial registration number: NCT04806607.).


Subject(s)
Endoscopic Ultrasound-Guided Fine Needle Aspiration , Liver , Needles , Humans , Female , Endoscopic Ultrasound-Guided Fine Needle Aspiration/instrumentation , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Middle Aged , Male , Prospective Studies , Adult , Liver/pathology , Aged , Liver Neoplasms/pathology , Biopsy, Large-Core Needle/instrumentation , Biopsy, Large-Core Needle/methods , Liver Diseases/pathology
9.
Gastroenterology ; 166(2): 345-349, 2024 02.
Article in English | MEDLINE | ID: mdl-38108671

ABSTRACT

DESCRIPTION: Subepithelial lesions of the gastrointestinal tract are not encountered uncommonly during routine endoscopy. There has been remarkable progress in the development of endoscopic options for the resection of subepithelial lesions, including full-thickness resection. The purpose of this American Gastroenterological Association (AGA) Clinical Practice Update (CPU) is to describe the various techniques for endoscopic full-thickness resection and to facilitate their appropriate application in the management of subepithelial lesions. METHODS: This CPU was commissioned and approved by the AGA Institute Clinical Practice Updates Committee (CPUC) and the AGA Governing Board to provide timely guidance on a topic of high clinical importance to the AGA membership and underwent internal peer review by the CPUC and external peer review through standard procedures of Gastroenterology.


Subject(s)
Endoscopic Mucosal Resection , Gastroenterology , Humans , Gastrointestinal Tract/surgery , Endoscopic Mucosal Resection/adverse effects , Endoscopic Mucosal Resection/methods , Endoscopy, Gastrointestinal/adverse effects , Endoscopy, Gastrointestinal/methods
10.
Gastrointest Endosc ; 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38042207

ABSTRACT

BACKGROUND AND AIMS: Endoscopic resection is standard treatment for adenomatous colorectal lesions. Depending on lesion morphology and resection technique, recurrence can occur. Scarred adenomas are challenging to resect and may require surgical management. This study evaluated the safety and effectiveness of an endoscopic powered resection (EPR) system for scarred adenomatous colorectal lesions. METHODS: This single-arm, prospective, multicenter study was conducted from January 2018 to January 2021 at 12 sites. Patients with persistent flat or sessile colorectal lesions were enrolled. Primary end points were technical success (the ability of the device to resect the lesion[s] without use of other resection devices without device-related serious adverse events [AEs]) and safety (the occurrence of AEs through 90 days). Secondary end points included endoscopic confirmation of resection completeness, occurrence of colon stenosis, disease persistence, and diagnostic value of resected specimens. RESULTS: Sixty-five patients were in the intention-to-treat/safety analysis population. Primary analysis was performed on 45 per-protocol (PP) patients with 48 lesions. All PP patients were solely treated by using the EPR device. Technical success was achieved in 44 (98%) patients. Three (5%) serious AEs occurred: 2 delayed self-limited bleeds and 1 perforation. Nonserious AEs included 4 (6%) cases of mild intraprocedural bleeding. Completeness of resection and histopathologic diagnosis of tissue specimens were achieved in all patients. Twenty-one (46.7%) patients had disease persistence after the first treatment, and there was no colon stenosis. CONCLUSIONS: EPR is safe and effective for benign, persistent, large (>20 mm), scarred colorectal adenomas and should be considered as an alternative treatment in lieu of surgery. A persistence rate of 46.7% indicates that >1 treatment is necessary for effective endoscopic treatment. (Clinical trial registration number: NCT04203667.).

11.
Cureus ; 15(10): e46424, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37927687

ABSTRACT

Introduction To assess the trends for liver biopsy (LB) indications, technique, and histopathologic diagnosis, we retrospectively evaluated liver biopsies in two one-year periods, separated by a decade. Methods A pathology database query was performed for all parenchymal LB in patients over 18 years (11/2017 to 10/2018) and compared to those performed over a one-year period, a decade ago. We identified 427 parenchymal liver biopsies in the recent group and 166 in the decade-old group. Results Elevated liver enzymes are the most common indication for LB. Non-alcoholic fatty liver disease (NAFLD) has become the most common diagnosis compared to 10 years ago, when it was viral hepatitis. Routes of LB were significantly different between the two groups, endoscopic ultrasound-guided liver biopsy (EUS-LB) (80.3% vs 0; p<0.0001), computed tomography-guided (0 vs 42.8%, p<0.0001), percutaneous by gastroenterologists (0% vs 29.5%, p<0.0001), and transjugular-LB (15.1% vs 17.6%, p<0.0001). The adequacy of the tissue for pathological diagnosis was similar, and there was no difference in adverse events. Conclusion At our institution, practice patterns have changed significantly for liver biopsy. There has been an increase in liver biopsy volume, and EUS guidance has become the most common approach for liver biopsy.

13.
Gastroenterology Res ; 16(5): 254-261, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37937229

ABSTRACT

Background: Endoscopic mucosal resection is a frequently employed method for removing colonic polyps. Nonetheless, the recurrence of these polyps over a healed submucosal base can complicate the extraction of leftover lesions through standard procedures. EndoRotor®, a non-thermal device specifically designed for endoscopic mucosal resection, has recently been assessed for its utility in removing colonic polyps, non-dysplastic Barrett's esophagus, and pancreatic necrosis. We conducted a systematic review and meta-analysis to ascertain the safety and efficacy of EndoRotor® in resecting scared or recurrence colonic polyps. Methods: We conducted an exhaustive review of existing literature using databases such as Medline, Embase, Web of Science, and the Cochrane Library until January 2023. Our aim was to find all studies that assessed the safety of non-thermal endoscopic resection devices in removing colonic polyps. The primary outcome we focused on was the rate of technical success. Secondary outcomes that we considered included the frequency of remaining lesions and instances of adverse events. To analyze these data, we used comprehensive meta-analysis software. Results: Our analysis incorporated three studies comprising 54 patients who underwent resection of 60 lesions. The combined technical success rate was 93.9% (95% confidence interval (CI): 77.7-98.6%, I2 = 25.5%). In patients who had another endoscopic examination, 20 were found to have a residual lesion. After the initial session, the combined rate of remaining lesions was 39.8% (95% CI: 15.3-70.8%, I2 = 74.5%). There were eight occurrences of intraoperative bleeding and four instances of bleeding post-procedure. The combined rate of intraoperative bleeding was 13.2% (95% CI: 6.7-24.3%, I2 = 0%), and post-procedure bleeding stood at 8.5% (95% CI: 3.4-19.8%, I2 = 0%). Only one major bleeding event was recorded, and no cases of perforation were reported. Conclusion: Our research indicates that the EndoRotor® effectively removes scarred colonic polyps, though the rate of remaining lesions is significant, potentially necessitating several sessions for a thorough removal. There is a need for broader prospective studies, mainly randomized controlled trials, to further assess EndoRotor®'s efficiency and safety in eliminating colonic polyps.

14.
VideoGIE ; 8(10): 401-403, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37849782

ABSTRACT

Video 1An overview of the case, background information on gastric volvulus, 3-dimensional models of the different types of gastric volvuli, and novel endoscopic and surgical techniques.

15.
Clin Transl Gastroenterol ; 14(11): e00631, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37622544

ABSTRACT

INTRODUCTION: Objective risk stratification is needed for patients with Barrett's esophagus (BE) to enable risk-aligned management to improve health outcomes. This study evaluated the predictive performance of a tissue systems pathology [TSP-9] test (TissueCypher) vs current clinicopathologic variables in a multicenter cohort of patients with BE. METHODS: Data from 699 patients with BE from 5 published studies on the TSP-9 test were evaluated. Five hundred nine patients did not progress during surveillance, 40 were diagnosed with high-grade dysplasia/esophageal adenocarcinoma (HGD/EAC) within 12 months, and 150 progressed to HGD/EAC after 12 months. Age, sex, segment length, hiatal hernia, original and expert pathology review diagnoses, and TSP-9 risk classes were collected. The predictive performance of clinicopathologic variables and the TSP-9 test was compared, and the TSP-9 test was evaluated in clinically relevant patient subsets. RESULTS: The sensitivity of the TSP-9 test in detecting progressors was 62.3% compared with 28.3% for expert-confirmed low-grade dysplasia (LGD), while the original diagnosis abstracted from medical records did not provide any significant risk stratification. The TSP-9 test identified 57% of progressors with nondysplastic Barrett's esophagus (NDBE) ( P < 0.0001). Patients with NDBE who scored TSP-9 high risk progressed at a similar rate (3.2%/yr) to patients with expert-confirmed LGD (3.7%/yr). The TSP-9 test provided significant risk stratification in clinically low-risk patients (NDBE, female, short-segment BE) and clinically high-risk patients (IND/LGD, male, long-segment BE) ( P < 0.0001 for comparison of high-risk classes vs low-risk classes). DISCUSSION: The TSP-9 test predicts risk of progression to HGD/EAC independently of current clinicopathologic variables in patients with BE. The test provides objective risk stratification results that may guide management decisions to improve health outcomes for patients with BE.


Subject(s)
Adenocarcinoma , Barrett Esophagus , Esophageal Neoplasms , Humans , Male , Female , Barrett Esophagus/pathology , Disease Progression , Esophageal Neoplasms/pathology , Adenocarcinoma/pathology , Hyperplasia
16.
Genet Med ; 25(12): 100949, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37542411

ABSTRACT

PURPOSE: Genomic screening can improve clinical outcomes, but presentation of individuals with risk for polyposis identified via genomic screening is unknown. To inform assessment of clinical utility of genomic screening for polyposis risk, clinical presentation of individuals in an unselected health care system cohort with an APC pathogenic or likely pathogenic (P/LP) variant causative of familial adenomatous polyposis are described. METHODS: Electronic health records of individuals with an APC P/LP variant identified via the MyCode program (MyCode APC+) were reviewed to assess adenoma burden and compare it among individuals with a clinical diagnosis of familial adenomatous polyposis and matched variant-negative controls. RESULTS: The prevalence of APC P/LP variants in this health care cohort is estimated to be 1 in 2800. Twenty-four MyCode APC+ individuals were identified during the study period. Median age at result disclosure was 53 years. Rate of clinical polyposis was 8%. Two of six participants with a classic region variant and none of those with an attenuated region variant had polyposis. MyCode APC+ participants did not differ from controls in cumulative adenoma count. CONCLUSION: APC P/LP variant prevalence estimate in the MyCode cohort is higher than prior published prevalence rates. Individuals with APC P/LP variants identified via genomic screening had a low adenoma burden.


Subject(s)
Adenoma , Adenomatous Polyposis Coli , Colorectal Neoplasms , Humans , Middle Aged , Adenoma/diagnosis , Adenoma/epidemiology , Adenoma/genetics , Adenomatous Polyposis Coli/epidemiology , Adenomatous Polyposis Coli/genetics , Adenomatous Polyposis Coli/pathology , Adenomatous Polyposis Coli Protein/genetics , Colorectal Neoplasms/genetics , Genes, APC
17.
Endosc Int Open ; 11(5): E519-E526, 2023 May.
Article in English | MEDLINE | ID: mdl-37206694

ABSTRACT

Background and study aims Endoscopic removal of complex colorectal polyps (≥ 2 cm) can be technically challenging. A dual balloon endoluminal overtube platform (DBEP) was developed to facilitate colonoscopic polypectomy. The study purpose was to evaluate clinical outcomes with the DBEP for complex polypectomy. Patients and methods This was an observational, prospective, multicenter Institutional Review Board-approved study. Between January 2018 and December 2020, safety and performance data were collected intra-procedurally and at 1 month post-procedure in patients undergoing intervention with the DBEP at three US centers. The primary endpoint was device safety and technical success of the procedure. Secondary endpoints included navigation time, total procedure time, and user feedback assessment post-procedure. Results A total of 162 patients underwent colonoscopy with the DBEP. Of these, 144 (89 %) underwent 156 interventions successfully with DBEP (44.5 % endoscopic mucosal resection, 53.2 % hybrid endoscopic submucosal dissection (ESD)/ESD, 1.3 % other). In 13 patients (8 %), device challenges contributed to unsuccessful intervention. One mild device-related adverse event (AE) occurred. Procedural AE rate was 8.3 %. Median lesion size was 2.6 cm [range 0.5-12]. The investigators felt that navigating the device was easy/somewhat easy in 78.5 % of successful cases. Median total procedure time was 69 minutes [range, 19-213], median navigation time to lesion was 8 minutes [range, 1-80], And median polypectomy time was 33.5 minutes [range, 2-143]. Conclusions Endoscopic colon polyp resection with the DBEP was safe with a high technical success rate. The DBEP has the potential to provide enhanced scope stability and visualization, traction, and a conduit for scope exchange. Further prospective randomized studies are warranted.

18.
Endosc Int Open ; 11(4): E401-E408, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37102183

ABSTRACT

Background and study aims Up to 80 % of patients with pancreatic adenocarcinoma develop locoregional recurrence after primary resection. However, the detection of recurrent pancreatic ductal adenocarcinoma (RPDAC) after pancreatic surgery can be challenging because of difficulty distinguishing locoregional recurrence from normal postoperative or post-radiation changes. We sought to evaluate the utility of endoscopic ultrasound (EUS), in detecting pancreatic adenocarcinoma recurrence after surgical resection and its impact on the clinical management of patients. Patients and methods This was a retrospective study of all pancreatic cancer patients who underwent EUS post-resection at two tertiary care centers between January 2004 and June 2019. Results Sixty-seven patients were identified. Of these, 57 (85 %) were diagnosed with RPDAC, resulting in change in clinical management of 46 (72 %) patients. EUS identified masses not seen on computed tomography, magnetic resonance imaging, or positron emission tomography in seven (14 %). Conclusions EUS is useful in detecting RPDAC after pancreatic surgery and can lead to significant impact on clinical management.

19.
ACG Case Rep J ; 10(2): e01001, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36891184

ABSTRACT

Lumen-apposing metal stents (LAMSs) have been widely used for drainage of peripancreatic collections. A 71-year-old woman with a history of necrotizing pancreatitis who underwent LAMS placement 3 months ago for symptomatic pancreatic fluid collection presented with hematochezia and hemodynamic instability. Computed tomographic angiography of the abdomen showed concerns for stent erosion into the splenic artery. Esophagogastroduodenoscopy revealed a large pulsating nonbleeding vessel within the LAMS. She underwent a mesenteric angiogram, which showed splenic artery pseudoaneurysm, and coil embolization was performed. Gastrointestinal bleeding secondary to pseudoaneurysm should be considered in patients with recent LAMS placement who present with signs of gastrointestinal bleeding.

20.
Surg Endosc ; 37(5): 3701-3709, 2023 05.
Article in English | MEDLINE | ID: mdl-36650353

ABSTRACT

BACKGROUND: Revision of a failed laparoscopic fundoplication carries higher risk of complication and lower chance of success compared to the original surgery. Transoral incisionless fundoplication (TIF) may be an endoscopic alternative for select GERD patients without need of a moderate/large hiatal hernia repair. The aim of this study was to assess feasibility, efficacy, and safety of TIF 2.0 after failed laparoscopic Nissen or Toupet fundoplication (TIFFF). METHODS: This is a multicenter retrospective cohort study of patients who underwent TIFFF between September 2017 and December 2020 using TIF 2.0 technique (EsophyX Z/Z+) performed by gastroenterologists and surgeons. Patients were included if they had (1) recurrent GERD symptoms, (2) pathologic reflux based upon pH testing or Grade C/D esophagitis or Barrett's esophagus, and (3) hiatal hernia ≤ 2 cm. The primary outcome was improvement in GERD Health-Related Quality of Life (GERD-HRQL) post-TIFFF. The TIFFF cohort was also compared to a similar surgical re-operative cohort using propensity score matching. RESULTS: Twenty patients underwent TIFFF (median 4.1 years after prior fundoplication) and mean GERD-HRQL score improved from 24.3 ± 22.9 to 14.75 ± 21.6 (p = 0.014); mean Reflux Severity Index (RSI) score improved from 14.1 ± 14.6 to 9.1 ± 8.0 (p = 0.046) with 8/10 (80%) of patients with normal RSI (< 13) post-TIF. Esophagitis healed in 78% of patients. PPI use decreased from 85 to 55% with 8/20 (45%) patients off of PPI. Importantly, mean acid exposure time decreased from 12% ± 17.8 to 0.8% ± 1.1 (p = 0.028) with 9/9 (100%) of patients with normalized pH post-TIF. There were no statistically significant differences in clinical efficacy outcomes between TIFFF and surgical revision, but TIFFF had significantly fewer late adverse events. CONCLUSION: Endoscopic rescue with TIF is a safe and efficacious alternative to redo laparoscopic surgery in symptomatic patients with appropriate anatomy and objective evidence of persistent or recurrent reflux.


Subject(s)
Esophagitis , Gastroesophageal Reflux , Laparoscopy , Humans , Fundoplication/adverse effects , Fundoplication/methods , Retrospective Studies , Quality of Life , Gastroesophageal Reflux/etiology , Gastroesophageal Reflux/surgery , Gastroesophageal Reflux/diagnosis , Treatment Outcome , Esophagitis/etiology , Esophagitis/surgery , Laparoscopy/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...