Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
Clin Radiol ; 78(9): e608-e612, 2023 09.
Article in English | MEDLINE | ID: mdl-37225571

ABSTRACT

AIM: To assess the potential correlation of the laterality of a cerebrospinal fluid (CSF)-venous fistula with the laterality of decubitus computed tomography (CT) myelogram (post decubitus digital subtraction myelogram) based on which side demonstrated more renal contrast medium excretion. MATERIALS AND METHODS: Patients with CSF-venous fistulas diagnosed at lateral decubitus digital subtraction myelograms were reviewed retrospectively. Patients who did not have CT myelogram following one or both left and right lateral decubitus digital subtraction myelograms were excluded. Two neuroradiologists independently interpreted the CT myelogram for the presence or absence of renal contrast, and whether subjectively more renal contrast medium was visualised on the left or right lateral decubitus CT myelogram. RESULTS: Renal contrast medium was seen in lateral decubitus CT myelograms in 28 of 30 (93.3%) patients with CSF-venous fistulas. Having more renal contrast medium in right lateral decubitus CT myelogram was 73.9% sensitive and 71.4% specific for the diagnosis of a right-sided CSF-venous fistula, whereas having more renal contrast medium in the left lateral decubitus CT myelogram was 71.4% sensitive and 82.6% specific for a left-sided CSF-venous fistula (p=0.02). CONCLUSION: When the CSF-venous fistula lies on the dependent side of a decubitus CT myelogram performed after decubitus digital subtraction myelogram, relatively more renal contrast medium is visualised compared to when the fistula lies on the non-dependent side.


Subject(s)
Fistula , Intracranial Hypotension , Humans , Retrospective Studies , Cerebrospinal Fluid Leak/diagnostic imaging , Tomography, X-Ray Computed/methods , Kidney
2.
AJNR Am J Neuroradiol ; 44(5): 618-622, 2023 05.
Article in English | MEDLINE | ID: mdl-37080723

ABSTRACT

BACKGROUND AND PURPOSE: Wrong-level spinal surgery, especially in the thoracic spine, remains a challenge for a variety of reasons related to visualization, such as osteopenia, large body habitus, severe kyphosis, radiographic misinterpretation, or anatomic variation. Preoperative fiducial marker placement performed in a dedicated imaging suite has been proposed to facilitate identification of thoracic spine vertebral levels. In this current study, we report our experience using image-guided percutaneous gold fiducial marker placement to enhance the accuracy and safety of thoracic spinal surgical procedures. MATERIALS AND METHODS: A retrospective review was performed of all fluoroscopy- or CT-guided gold fiducial markers placed at our institution between January 3, 2019, and March 16, 2022. A chart review of 179 patients was performed detailing the procedural approach and clinical information. In addition, the method of gold fiducial marker placement (fluoroscopy/CT), procedure duration, spinal level of the gold fiducial marker, radiation dose, fluoroscopy time, surgery date, and complications (including whether wrong-level surgery occurred) were recorded. RESULTS: A total of 179 patients (104 female) underwent gold fiducial marker placement. The mean age was 57 years (range, 12-96 years). Fiducial marker placement was performed by 13 different neuroradiologists. All placements were technically successful without complications. All 179 (100%) operations were performed at the correct level. Most fiducial markers (143) were placed with fluoroscopy with the most common location at T6-T8. The most common location for placement in CT was at T3 and T4. CONCLUSIONS: All operations guided with gold fiducial markers were performed at the correct level. There were no complications of fiducial marker placement.


Subject(s)
Fiducial Markers , Gold , Humans , Female , Middle Aged , Tomography, X-Ray Computed/methods , Spine/diagnostic imaging , Spine/surgery , Fluoroscopy/methods
3.
AJNR Am J Neuroradiol ; 43(4): 579-584, 2022 04.
Article in English | MEDLINE | ID: mdl-35332019

ABSTRACT

BACKGROUND AND PURPOSE: Photon-counting detector CT is a new technology with a limiting spatial resolution of ≤150 µm. In vivo comparisons between photon-counting detector CT and conventional energy-integrating detector CT are needed to determine the clinical impact of photon counting-detector CT in temporal bone imaging. MATERIALS AND METHODS: Prospectively recruited patients underwent temporal bone CT examinations on an investigational photon-counting detector CT system after clinically indicated temporal bone energy-integrating detector CT. Photon-counting detector CT images were obtained at an average 31% lower dose compared with those obtained on the energy-integrating detector CT scanner. Reconstructed images were evaluated in axial, coronal, and Pöschl planes using the smallest available section thickness on each system (0.4 mm on energy-integrating detector CT; 0.2 mm on photon-counting detector CT). Two blinded neuroradiologists compared images side-by-side and scored them using a 5-point Likert scale. A post hoc reassignment of readers' scores was performed so that the scores reflected photon-counting detector CT performance relative to energy-integrating detector CT. RESULTS: Thirteen patients were enrolled, resulting in 26 image sets (left and right sides). The average patient age was 63.6 [SD, 13.4] years; 7 were women. Images from the photon-counting detector CT scanner were significantly preferred by the readers in all reconstructed planes (P < .001). Photon-counting detector CT was rated superior for the evaluation of all individual anatomic structures, with the oval window (4.79) and incudostapedial joint (4.75) receiving the highest scores on a Likert scale of 1-5. CONCLUSIONS: Temporal bone CT images obtained on a photon-counting detector CT scanner were rated as having superior spatial resolution and better critical structure visualization than those obtained on a conventional energy-integrating detector scanner, even with a substantial dose reduction.


Subject(s)
Photons , Tomography, X-Ray Computed , Female , Humans , Middle Aged , Phantoms, Imaging , Radiation Dosage , Temporal Bone/diagnostic imaging , Tomography, X-Ray Computed/methods
4.
AJNR Am J Neuroradiol ; 43(1): 117-124, 2022 01.
Article in English | MEDLINE | ID: mdl-34887246

ABSTRACT

BACKGROUND AND PURPOSE: Percutaneous CT-guided core needle biopsies of head and neck lesions can be safely performed with vigilant planning. This largest-to-date single-center retrospective study evaluates multiple approaches with consideration of special techniques and examines the histopathologic yield. MATERIALS AND METHODS: Retrospective review of CT-guided core biopsies of head and neck lesions from January 1, 2010, to October 30, 2020, was performed. We recorded the following: patient demographics, sedation details, biopsy needle type and size, lesion location and size, approach, patient positioning, preprocedural intravenous contrast, proceduralists' years of experience, complications, and pathology results. RESULTS: One hundred eighty-four CT-guided core biopsies were evaluated. The initial diagnostic yield was 93% (171/184). However, of 43/184 (23%) originally "negative for malignancy" biopsies, 4 were eventually positive for malignancy via rebiopsy/excision, resulting in a 2% false-negative rate and an adjusted total diagnostic yield of 167/184 (91%). Biopsies were performed by 16 neuroradiologists with variable experience. The diagnostic yield was essentially the same: 91% (64/70) for proceduralists with ≤3 years' experience, and 90% (103/114) with >3 years' experience. The diagnostic yield was 93% (155/166) for lesions of >10 mm. The diagnostic yield per biopsy needle gauge was the following: 20 ga, 81% (13/16); 18 ga, 93% (70/75); 16 ga, 90% (64/71); and 14 ga, 91% (20/22). There were 4 asymptomatic hematomas, with none requiring intervention. CONCLUSIONS: Percutaneous CT-guided core needle biopsies are safe procedures for superficial and deep head and neck lesions with a high diagnostic yield. Careful planning and special techniques may increase the number of lesions accessible percutaneously while minimizing the risk of complications.


Subject(s)
Image-Guided Biopsy , Tomography, X-Ray Computed , Biopsy, Large-Core Needle/adverse effects , Biopsy, Large-Core Needle/methods , Humans , Image-Guided Biopsy/methods , Neck , Retrospective Studies , Tomography, X-Ray Computed/methods
5.
AJNR Am J Neuroradiol ; 42(7): E45, 2021 07.
Article in English | MEDLINE | ID: mdl-33888455
6.
AJNR Am J Neuroradiol ; 42(1): 12-21, 2021 01.
Article in English | MEDLINE | ID: mdl-33184072

ABSTRACT

Postoperative temporal bone imaging after surgical procedures such as ossiculoplasty, tympanomastoidectomy, cochlear implantation, and vestibular schwannoma resection is often encountered in clinical neuroradiology practice. Less common otologic procedures can present diagnostic dilemmas, particularly if access to prior operative reports is not possible. Lack of familiarity with the less common surgical procedures and expected postoperative changes may render radiologic interpretation challenging. This review illustrates key imaging findings after surgery for Ménière disease, superior semicircular canal dehiscence, temporal encephalocele repairs, internal auditory canal decompression, active middle ear implants, jugular bulb and sigmoid sinus dehiscence repair, and petrous apicectomy.


Subject(s)
Otologic Surgical Procedures/methods , Temporal Bone/diagnostic imaging , Temporal Bone/surgery , Tomography, X-Ray Computed/methods , Cranial Sinuses/diagnostic imaging , Cranial Sinuses/surgery , Female , Humans , Male , Middle Aged , Skull Base/diagnostic imaging , Skull Base/surgery
7.
AJNR Am J Neuroradiol ; 41(12): 2176-2187, 2020 12.
Article in English | MEDLINE | ID: mdl-33093137

ABSTRACT

Paraneoplastic syndromes are systemic reactions to neoplasms mediated by immunologic or hormonal mechanisms. The most well-recognized paraneoplastic neurologic syndrome, both clinically and on imaging, is limbic encephalitis. However, numerous additional clinically described syndromes affect the brain, spinal cord, and peripheral nerves. Many of these syndromes can have imaging findings that, though less well described, are important in making the correct diagnosis. Moreover, imaging in these syndromes frequently mimics more common pathology, which can be a diagnostic challenge for radiologists. Our goal is to review the imaging findings of paraneoplastic neurologic syndromes, including less well-known entities and atypical presentations of common entities. Specifically, we discuss limbic encephalitis, paraneoplastic cerebellar degeneration, paraneoplastic brain stem encephalitis, cranial neuropathy, myelitis, and polyneuropathy. We also demonstrate common diagnostic pitfalls that can be encountered when imaging these patients.


Subject(s)
Neuroimaging/methods , Paraneoplastic Syndromes, Nervous System/diagnostic imaging , Humans , Middle Aged , Paraneoplastic Syndromes, Nervous System/pathology
8.
AJNR Am J Neuroradiol ; 41(10): 1958-1962, 2020 10.
Article in English | MEDLINE | ID: mdl-32855185

ABSTRACT

BACKGROUND AND PURPOSE: Inadvertent subdural contrast injections can occur during any myelogram. Currently, there are no guidelines defining when residual subdural iodinated contrast will be cleared and no longer interfere with subsequent procedure and imaging. We investigated the time to resolution of subdural contrast using a 2-day lateral decubitus digital subtraction myelogram and associated CT myelogram data in patients undergoing evaluation for spontaneous intracranial hypotension. MATERIALS AND METHODS: Retrospective review of 63 patients with lateral decubitus digital subtraction myelograms from September 4, 2018, to October 1, 2019, was performed. Patients with 2-day lateral decubitus digital subtraction myelograms on 2 consecutive days, with or without a same-day CT myelogram on day 1 and with a same-day CT myelogram on day 2, were included. Patients with next-day CT covering at least the abdomen and pelvis after either-day injection were also included. In cases of subdural injection, next-day CT scans were evaluated for residual subdural contrast. RESULTS: Of 49 included patients, 5 had subdural injection on day 1, with the second-day CT myelogram available for review. One of these 5 patients had subdural injections on 2 different days and subsequently had chest/abdomen/pelvis CTA a day after the second subdural injection. In all 6 cases of subdural injections, there was complete resolution of subdural contrast on the next-day CT, with the shortest time to resolution of approximately 20.5 hours (range, 20.5-28.5 hours). CONCLUSIONS: Our study suggests that resolution of inadvertently injected subdural contrast occurs within 1 day, and the myelogram can be reattempted as early as the next day.


Subject(s)
Contrast Media/administration & dosage , Intracranial Hypotension/diagnostic imaging , Myelography/methods , Subdural Space , Adult , Aged , Female , Humans , Male , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed/methods
9.
AJNR Am J Neuroradiol ; 41(8): 1339-1347, 2020 08.
Article in English | MEDLINE | ID: mdl-32646948

ABSTRACT

Spontaneous intracranial hypotension is a condition characterized by low CSF volume secondary to leakage through a dural defect with no identifiable cause. Patients classically present with orthostatic headaches, but this symptom is not specific to spontaneous intracranial hypotension, and initial misdiagnosis is common. The most prominent features of spontaneous intracranial hypotension on intracranial MR imaging include "brain sag" and diffuse pachymeningeal enhancement, but these characteristics can be seen in several other conditions. Understanding the clinical and imaging features of spontaneous intracranial hypotension and its mimickers will lead to more prompt and accurate diagnoses. Here we discuss conditions that mimic the radiologic and clinical presentation of spontaneous intracranial hypotension as well as other disorders that CSF leaks can imitate.


Subject(s)
Intracranial Hypotension/diagnostic imaging , Diagnosis, Differential , Female , Humans , Magnetic Resonance Imaging/methods , Male
10.
AJNR Am J Neuroradiol ; 41(1): 21-28, 2020 01.
Article in English | MEDLINE | ID: mdl-31857327

ABSTRACT

Digital subtraction myelography is a valuable diagnostic technique to detect the exact location of CSF leaks in the spine to facilitate appropriate diagnosis and treatment of spontaneous spinal CSF leaks. Digital subtraction myelography is an excellent diagnostic tool for assessment of various types of CSF leaks, and lateral decubitus digital subtraction myelography is increasingly being used to diagnose CSF-venous fistulas. Lateral decubitus digital subtraction myelography differs from typical CT and fluoroscopy-guided myelograms in many ways, including equipment, supplies, and injection and image-acquisition techniques. Operators should be familiar with techniques, common pitfalls, and artifacts to improve diagnostic yield and prevent nondiagnostic examinations.


Subject(s)
Cerebrospinal Fluid Leak/diagnostic imaging , Myelography/methods , Female , Humans , Male
11.
AJNR Am J Neuroradiol ; 40(10): 1779-1785, 2019 10.
Article in English | MEDLINE | ID: mdl-31558502

ABSTRACT

BACKGROUND AND PURPOSE: Prior retrospective studies have suggested that both T2 hyperintensity and gadolinium enhancement on fat-suppressed MR imaging are associated with lumbar facet joint pain, but prospective evaluation of FDG-PET/MR imaging with a standardized protocol and correlation to clinical findings are lacking. The primary aim was to prospectively assess a standardized FDG-PET/MRI protocol in patients with suspected facetogenic low back pain, with determination of the concordance of imaging and clinical findings. MATERIALS AND METHODS: Ten patients with clinically suspected facetogenic low back pain were prospectively recruited with a designation of specific facet joints implicated clinically. Subsequently, patients underwent an FDG-PET/MR imaging examination with gadolinium. Each facet joint was graded for perifacet signal change on MR imaging and FDG activity. The frequency and correlation of MR imaging, FDG-PET, and clinical findings were determined. RESULTS: FDG activity showed high concordance with high overall MR imaging scores (concordance correlation coefficient = 0.79). There was concordance of the clinical side of pain with the side of high overall MR imaging scores and increased FDG activity on 12/20 (60%) sides. Both a high overall MR imaging score (concordance correlation coefficient = 0.12) and FDG-PET findings positive for increased activity (concordance correlation coefficient = 0.10) had low concordance with the specific clinically implicated facet joints. Increased FDG activity or high MR imaging scores or both were present in only 10/29 (34%) facet joints that had been clinically selected for percutaneous intervention. Eleven (11%) facet joints that had not been selected for treatment demonstrated these imaging findings. CONCLUSIONS: There was low concordance of perifacet signal change and FDG activity with clinically implicated facet joints. This could indicate either the potential to change patient management or a lack of biomarker accuracy. Therefore, additional larger randomized studies with the use of comparative medial branch blocks would be useful to further investigate the clinical utility of these findings.


Subject(s)
Low Back Pain/diagnostic imaging , Magnetic Resonance Imaging/methods , Multimodal Imaging/methods , Positron-Emission Tomography/methods , Zygapophyseal Joint/diagnostic imaging , Contrast Media , Female , Fluorodeoxyglucose F18 , Gadolinium , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Prospective Studies , Retrospective Studies
12.
AJNR Am J Neuroradiol ; 40(5): 908-915, 2019 05.
Article in English | MEDLINE | ID: mdl-31048295

ABSTRACT

BACKGROUND AND PURPOSE: Epidural steroid injections may offer little-to-no short-term benefit in the overall population of patients with symptomatic spinal stenosis compared with lidocaine alone. We investigated whether imaging could identify subgroups of patients who might benefit most. MATERIALS AND METHODS: A secondary analysis of the Lumbar Epidural Steroid Injections for Spinal Stenosis prospective, double-blind trial was performed, and patients were randomized to receive an epidural injection of lidocaine with or without corticosteroids. Patients (n = 350) were evaluated for qualitative and quantitative MR imaging or CT measures of lumbar spinal stenosis. The primary clinical end points were the Roland-Morris Disability Questionnaire and the leg pain numeric rating scale at 3 weeks following injection. ANCOVA was used to assess the significance of interaction terms between imaging measures of spinal stenosis and injectate type on clinical improvement. RESULTS: There was no difference in the improvement of disability or leg pain scores at 3 weeks between patients injected with epidural lidocaine alone compared with corticosteroid and lidocaine when accounting for the primary imaging measures of qualitative spinal stenosis assessment (interaction coefficients for disability score, -0.1; 95% CI, -1.3 to 1.2; P = .90; and for the leg pain score, 0.1; 95% CI, -0.6 to 0.8; P = .81) or the quantitative minimum thecal sac cross-sectional area (interaction coefficients for disability score, 0.01; 95% CI, -0.01 to 0.03; P = .40; and for the leg pain score, 0.01; 95% CI, -0.01 to 0.03; P = .33). CONCLUSIONS: Imaging measures of spinal stenosis are not associated with differential clinical responses following epidural corticosteroid injection.


Subject(s)
Adrenal Cortex Hormones/administration & dosage , Lidocaine/administration & dosage , Spinal Stenosis/diagnostic imaging , Spinal Stenosis/drug therapy , Treatment Outcome , Adult , Aged , Anesthetics, Local/administration & dosage , Anti-Inflammatory Agents/administration & dosage , Double-Blind Method , Drug Therapy, Combination/methods , Female , Humans , Injections, Epidural/methods , Lumbar Vertebrae , Magnetic Resonance Imaging/methods , Male , Middle Aged , Randomized Controlled Trials as Topic , Retrospective Studies , Spinal Stenosis/pathology , Tomography, X-Ray Computed/methods
13.
AJNR Am J Neuroradiol ; 40(2): 376-381, 2019 02.
Article in English | MEDLINE | ID: mdl-30655256

ABSTRACT

BACKGROUND AND PURPOSE: The significance of renal contrast on CT myelography is uncertain. This project examined different patient populations undergoing CT myelography for the presence of renal contrast to determine whether this finding is of diagnostic value in spontaneous intracranial hypotension. MATERIALS AND METHODS: Four groups of patients were analyzed for renal contrast on CT myelography. The control group underwent CT myelography for reasons other than spontaneous intracranial hypotension (n = 47). Patients in study group 1 had spontaneous intracranial hypotension but CT myelography negative for dural CSF leak and CSF venous fistula (n = 83). Patients in study group 2 had spontaneous intracranial hypotension and CT myelography positive for dural CSF leak (n = 44). Patients in study group 3 had spontaneous intracranial hypotension and CT myelography suggestive of CSF venous fistula due to a hyperdense paraspinal vein (n = 17, eleven surgically confirmed). RESULTS: Renal contrast was present on the initial CT myelography in 0/47 patients in the control group, 10/83 patients in group one, 1/44 patients in group 2, and 7/17 patients in group 3. Renal contrast on initial CT myelography in patients with suspected or surgically confirmed CSF venous fistula was significantly more likely than in patients with a dural CSF leak (P = .0003). CONCLUSIONS: Renal contrast on initial CT myelography was seen only in patients with spontaneous intracranial hypotension. This was more common in confirmed/suspected CSF venous fistulas compared with dural leaks. Early renal contrast in patients with spontaneous intracranial hypotension should prompt scrutiny for a hyperdense paraspinal vein, and, if none is found, potentially advanced diagnostic studies.


Subject(s)
Cerebrospinal Fluid Leak/diagnostic imaging , Intracranial Hypotension/diagnostic imaging , Kidney Tubules, Collecting/diagnostic imaging , Adult , Cerebrospinal Fluid Leak/complications , Female , Humans , Intracranial Hypotension/etiology , Male , Middle Aged , Myelography , Tomography, X-Ray Computed
14.
AJNR Am J Neuroradiol ; 39(9): 1584-1592, 2018 09.
Article in English | MEDLINE | ID: mdl-29348133

ABSTRACT

Vertebral compression fractures are very common, especially in the elderly. Benign osteoporotic and malignant vertebral compression fractures have extremely different management and prognostic implications. Although there is an overlap in appearances, characteristic imaging features can aid in the distinction between these 2 types of compression fractures. The aim of this review is to characterize the imaging features of benign and malignant vertebral compression fractures seen with CT, PET, SPECT, and MR imaging.


Subject(s)
Fractures, Compression/diagnostic imaging , Osteoporosis/complications , Spinal Fractures/diagnostic imaging , Spinal Neoplasms/complications , Aged , Diagnostic Imaging/methods , Female , Fractures, Compression/etiology , Fractures, Spontaneous/diagnostic imaging , Fractures, Spontaneous/etiology , Humans , Male , Middle Aged , Spinal Fractures/etiology
15.
AJNR Am J Neuroradiol ; 38(4): 672-677, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28183836

ABSTRACT

BACKGROUND AND PURPOSE: Given the positive impact of early intervention for craniosynostosis, CT is often performed for evaluation but radiation dosage remains a concern. We evaluated the potential for substantial radiation dose reduction in pediatric patients with suspected craniosynostosis. MATERIALS AND METHODS: CT projection data from pediatric patients undergoing head CT for suspected craniosynostosis were archived. Simulated lower-dose CT images corresponding to 25%, 10%, and 2% of the applied dose were created using a validated method. Three neuroradiologists independently interpreted images in a blinded, randomized fashion. All sutures were evaluated by using 3D volume-rendered images alone, and subsequently with 2D and 3D images together. Reference standards were defined by reader agreement by using routine dose and 2D and 3D images. Performance figures of merit were calculated based on reader response and confidence. RESULTS: Of 33 pediatric patients, 21 had craniosynostosis (39 positive sutures and 225 negative sutures). The mean volume CT dose index was 15.5 ± 2.3 mGy (range, 9.69-19.38 mGy) for the routine dose examination. Average figures of merit for multireader analysis ranged from 0.92 (95% CI, 0.90-0.95) at routine pediatric dose to 0.86 (95% CI, 0.79-0.94) at 2% dose using 3D images alone. Similarly, pooled reader figures of merit ranged from 0.91 (95% CI, 0.89-0.95) at routine pediatric dose to 0.85 (95% CI, 0.76-0.95) at 2% dose using 2D and 3D images together. At 25% and 10% dose, 95% CI of the difference in figures of merit from routine dose included 0, suggesting similar or noninferior performance. CONCLUSIONS: For pediatric head CT for evaluation of craniosynostosis, dose reductions of 75%-90% were possible without compromising observer performance.


Subject(s)
Craniosynostoses/diagnostic imaging , Tomography, X-Ray Computed/methods , Female , Humans , Imaging, Three-Dimensional/methods , Male , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods
16.
AJNR Am J Neuroradiol ; 38(4): 678-684, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28126746

ABSTRACT

BACKGROUND AND PURPOSE: In 2016, the World Health Organization revised the brain tumor classification, making IDH mutation and 1p/19q codeletion the defining features of oligodendroglioma. To determine whether imaging characteristics previously associated with oligodendroglial tumors are still applicable, we evaluated the MR imaging features of genetically defined oligodendrogliomas. MATERIALS AND METHODS: One hundred forty-eight adult patients with untreated World Health Organization grade II and III infiltrating gliomas with histologic oligodendroglial morphology, known 1p/19q status, and at least 1 preoperative MR imaging were retrospectively identified. The association of 1p/19q codeletion with tumor imaging characteristics and ADC values was evaluated. RESULTS: Ninety of 148 (61%) patients had 1p/19q codeleted tumors, corresponding to genetically defined oligodendroglioma, and 58/148 (39%) did not show 1p/19q codeletion, corresponding to astrocytic tumors. Eighty-three of 90 (92%) genetically defined oligodendrogliomas had noncircumscribed borders, compared with 26/58 (45%) non-1p/19q codeleted tumors with at least partial histologic oligodendroglial morphology (P < .0001). Eighty-nine of 90 (99%) oligodendrogliomas were heterogeneous on T1- and/or T2-weighted imaging. In patients with available ADC values, a lower mean ADC value predicted 1p/19q codeletion (P = .0005). CONCLUSIONS: Imaging characteristics of World Health Organization 2016 genetically defined oligodendrogliomas differ from the previously considered characteristics of morphologically defined oligodendrogliomas. We found that genetically defined oligodendrogliomas were commonly poorly circumscribed and were almost always heterogeneous in signal intensity.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/genetics , Magnetic Resonance Imaging/methods , Oligodendroglioma/diagnostic imaging , Oligodendroglioma/genetics , Adult , Aged , Brain Neoplasms/pathology , Chromosomes, Human, Pair 1 , Chromosomes, Human, Pair 19 , Female , Humans , Isocitrate Dehydrogenase/genetics , Male , Middle Aged , Mutation , Oligodendroglioma/pathology , Retrospective Studies
17.
AJNR Am J Neuroradiol ; 37(12): 2400-2406, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27758772

ABSTRACT

BACKGROUND AND PURPOSE: The role of vertebroplasty in patients with myeloma remains relatively undefined. Accordingly, we sought to better define the efficacy of vertebroplasty for myeloma-associated fractures and determine the effect of procedure timing relative to the initiation of systemic therapy on outcomes and complication rates. MATERIALS AND METHODS: Clinical, laboratory, and medication data were retrieved for 172 patients with multiple myeloma treated with vertebroplasty since October 2000. Quantitative outcome data (Roland-Morris Disability Questionnaire [scale, 0-24] and the Numeric Rating Scale [0-10] for pain at rest and with activity) were collected immediately pre- and postoperatively and at 1 week, 1 month, 6 months, and 1 year following vertebroplasty. Patients with ≥50% improvement on the Numeric Rating Scale and ≥40% improvement on the Roland-Morris Disability Questionnaire were classified as "responders." Peri- and postoperative complications were also collected. RESULTS: Significant median improvement in the Roland-Morris Disability and rest and activity Numeric Rating Scale scores (15, 2, and 6 points, respectively; P < .0001) persisted at 1 year without significant change from the immediate postoperative scores (P > .36). Patients on systemic therapy at the time of vertebroplasty were more likely to achieve "responder status," compared with patients not on systemic therapy, for the Numeric Rating Scale pain at rest score (P < .01) and the Roland-Morris Disability Questionnaire score (P < .003), with no difference in complication rates (χ2 = 0.17, P = .68). CONCLUSIONS: Vertebroplasty is an effective therapy for patients with myeloma with symptomatic compression fractures. Favorable outcomes are more likely to be achieved when spinal augmentation is performed after systemic therapy is initiated. Complication rates were not affected by the timing of systemic therapy.


Subject(s)
Multiple Myeloma/complications , Multiple Myeloma/therapy , Spinal Fractures/surgery , Vertebroplasty/methods , Adult , Aged , Female , Fractures, Compression/etiology , Fractures, Compression/surgery , Humans , Male , Middle Aged , Spinal Fractures/etiology , Treatment Outcome
18.
AJNR Am J Neuroradiol ; 37(11): 2171-2177, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27390313

ABSTRACT

Dorsal epidural migration of lumbar disc extrusion is rare and commonly misdiagnosed. Our purpose was to retrospectively analyze soft-tissue abnormalities on axial MR imaging in both the ventral and lateral epidural space in such dorsal epidural migrations. The presence of each component required complete concordance by 3 independent neuroradiologist readers. In a case series (n = 6) of surgically proved dorsal lumbar disc migrations, in which the radiologist's favored prospective diagnosis had not been correct, each case demonstrated epidural soft-tissue abnormality that had components both laterally and ventrally, abutting the parent disc. Similarly, in previously published cases for which axial MR imaging was available, the lateral component was demonstrated in 23/24 cases (96%). Ventral abutment of the parent disc was evident, in addition, in 17/18 cases (94%) with available disc-level axial images. Both ventral and lateral epidural soft-tissue abnormalities are typically present in dorsal lumbar disc herniations and may help radiologists suggest this rare diagnosis in appropriate cases.

19.
AJNR Am J Neuroradiol ; 37(8): 1567-72, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27012293

ABSTRACT

BACKGROUND AND PURPOSE: Imaging findings in patients with a combination of synovitis, acne, pustulosis, hyperostosis, and osteitis (SAPHO) are often misinterpreted as discitis/osteomyelitis or metastases, resulting in multiple biopsies and delayed diagnosis. We have incidentally noted a semicircular morphology in vertebral body imaging in several cases of SAPHO syndrome with vertebral involvement. Our goal was to evaluate the prevalence of this distinctive morphology in these patients. MATERIALS AND METHODS: A retrospective review of patients with SAPHO syndrome diagnosed between July 1998 and August 2013 was conducted. A descriptive analysis of MR imaging, CT, radiography, bone scanning, and PET imaging was performed for the presence and distribution of vertebral body signal intensity or attenuation changes and/or enhancement; contiguous vertebral body involvement; vertebral body collapse; endplate irregularity; disc space, facet, and spinous process involvement; subligamentous thickening; and paraspinal soft-tissue involvement. RESULTS: Eighteen patients (16 women [89%]; mean age, 52.9 years) with SAPHO and spine involvement were included. Contiguous involvement of ≥2 vertebral bodies was found in 16 patients (89%), with a curvilinear or "semicircular" pattern involving portions of adjacent vertebral bodies in 10 (63%, P = .14). Most intervertebral discs demonstrated absence of abnormal T2 hyperintensity (73%) and enhancement (89%). Subligamentous thickening was present in 12 (67%). Paraspinal soft-tissue involvement was present in 6 (33%). CONCLUSIONS: SAPHO syndrome should be included in the differential diagnosis in a patient with a curvilinear or semicircular pattern of vertebral involvement, contiguous vertebral body involvement, and absence of intervertebral disc edema and enhancement.


Subject(s)
Acquired Hyperostosis Syndrome/diagnostic imaging , Intervertebral Disc/diagnostic imaging , Acquired Hyperostosis Syndrome/pathology , Adult , Diagnosis, Differential , Discitis/diagnostic imaging , Discitis/pathology , Female , Humans , Intervertebral Disc/pathology , Magnetic Resonance Imaging/methods , Male , Middle Aged , Osteomyelitis/diagnosis , Osteomyelitis/diagnostic imaging , Retrospective Studies , Young Adult
20.
AJNR Am J Neuroradiol ; 37(1): 185-8, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26381563

ABSTRACT

BACKGROUND AND PURPOSE: We adopted an imaging algorithm in 2011 in which extradural fluid on spinal MR imaging directs dynamic CT myelography. We assessed algorithm compliance and its effectiveness in reducing repeat or unnecessary dynamic CT myelograms. MATERIALS AND METHODS: CT myelograms for CSF leaks from January 2011 to September 2014 were reviewed. Patients with iatrogenic leaks, traumatic brachial plexus injuries, or prior CT myelography within 2 years were excluded. Completion and results of spinal MR imaging, CT myelographic technique, and the need for repeat CT myelography or unnecessary dynamic CT myelograms were recorded. RESULTS: The algorithm was followed in 102 (79%) of 129 patients. No extradural fluid was detected in 75 (74%), of whom 70 (93%) had no leak, 4 (5%) had a slow leak, and 1 (1%) had a fast leak. Extradural fluid was detected in 27 (26%): 24 (89%) fast leaks, 1 (4%) slow leak, and 2 (7%) with no leaks. When the algorithm was followed, 1 (1%) required repeat CT myelography and 3 (3%) had unnecessary dynamic CT myelograms. The algorithm was breached in 27 (21%) cases, including no pre-CT myelogram MR imaging in 11 (41%), performing conventional CT myelography when extradural fluid was present in 13 (48%), and performing dynamic CT myelography when extradural fluid was absent in 3 (11%). Algorithm breaches resulted in 4 (15%) repeat CT myelograms and 3 (12%) unnecessary dynamic CT myelograms, both higher than with algorithm compliance. CONCLUSIONS: Using spinal MR imaging to direct CT myelography resulted in significant reduction in repeat CT myelograms to localize fast leaks with minimal unnecessary dynamic CT myelograms.


Subject(s)
Algorithms , Cerebrospinal Fluid Leak/diagnosis , Intracranial Hypotension/diagnosis , Magnetic Resonance Imaging/methods , Myelography/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Female , Guideline Adherence , Humans , Intracranial Hypotension/etiology , Male , Middle Aged , Unnecessary Procedures
SELECTION OF CITATIONS
SEARCH DETAIL
...